Index: Alarms/Alarms.conf =================================================================== diff -u -r5552074bb4b7da1d4eeb88f006ffb9e433157140 -r5e0ade5573953e8d9b766ca9f15df1a506af5d03 --- Alarms/Alarms.conf (.../Alarms.conf) (revision 5552074bb4b7da1d4eeb88f006ffb9e433157140) +++ Alarms/Alarms.conf (.../Alarms.conf) (revision 5e0ade5573953e8d9b766ca9f15df1a506af5d03) @@ -1,1604 +1,1496 @@ [0] -Title = +Title = ` Message = [1] -Title = Self Test Error -Message = Call service to schedule a repair. -Self Test Error = Call service to schedule a repair. +Title = HD POST: Stuck Button +Message = Stop or On button pressed during startup\n-Release button and power cycle\n-Call service to schedule a repair if problem persists [2] -Title = Self Test Error +Title = HD POST: FPGA Compatibility Message = Call service to schedule a repair. -Self Test Error = Call service to schedule a repair. [3] -Title = Self Test Error +Title = DG POST: FPGA Compatibility Message = Call service to schedule a repair. -Self Test Error = Call service to schedule a repair. +SRSDG 602 +SRSDG 814 +SRSDG 1061 = [4] -Title = Self Test Error +Title = HD POST: WD Safestate Message = Call service to schedule a repair. -Self Test Error = Call service to schedule a repair. [5] -Title = Self Test Error +Title = DG POST: WD Safestate Message = Call service to schedule a repair. -Self Test Error = Call service to schedule a repair. +SRSDG 53 = [6] -Title = Self Test Error +Title = HD POST: Proc-UI Comm Message = Call service to schedule a repair. -Self Test Error = Call service to schedule a repair. [7] -Title = Machine Error +Title = HD Alarm (Low): RTC Bat Low Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. [8] -Title = Self Test Error +Title = HD POST: Acc Vector Message = Call service to schedule a repair. -Self Test Error = Call service to schedule a repair. [9] -Title = Self Test Error +Title = DG POST: Acc Vector Message = Call service to schedule a repair. -Self Test Error = Call service to schedule a repair. +SRSDG 323 = [10] -Title = Machine Error +Title = HD POST: BLD Config Emb Mode Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. [11] -Title = Dialysate Temperature Error -Message = Call service to schedule a repair. -Dialysate Temperature Error = Call service to schedule a repair. +Title = Dial. Gen: Dialysate Temp Low +Message = Dialysate temperature is low\n- Treatment is paused and will be ready to resume when dialysate is within target range. [12] -Title = Self Test Error +Title = HD POST: HD Image Message = Call service to schedule a repair. -Self Test Error = Call service to schedule a repair. [13] -Title = Self Test Error +Title = DG POST: DG Image Message = Call service to schedule a repair. -Self Test Error = Call service to schedule a repair. +SRSDG 813 = [14] -Title = Self Test Error +Title = DG POST: Usage Rec NVRAM CRC Message = Call service to schedule a repair. -Self Test Error = Call service to schedule a repair. +SRSDG 957 = [15] -Title = Self Test Error -Message = Call service to schedule a repair. -Self Test Error = Call service to schedule a repair. +Title = Dial. Gen: Dialysate Temp High +Message = Dialysate temperature is high\n-Treatment is paused and will be ready to resume when dialysate is within target range. [16] -Title = Self Test Error +Title = HD POST: Primary Alarm Current Message = Call service to schedule a repair. -Self Test Error = Call service to schedule a repair. [17] -Title = Self Test Error +Title = HD POST: UI POST Not Complete Message = Call service to schedule a repair. -Self Test Error = Call service to schedule a repair. [18] -Title = Calibration Error -Message = Call service to schedule a repair. -Calibration Error = Call service to schedule a repair. +Title = +Message = [19] -Title = Dialysate Temperature Error -Message = Call service to schedule a repair. -Dialysate Temperature Error = Call service to schedule a repair. +Title = Dial. Gen: Dialysate Temp High +Message = Dialysate temperature is high\n- Treatment is paused and will be ready to resume when dialysate is within target range. [20] -Title = Calibration Error +Title = DG POST: Conductivity Cal Message = Call service to schedule a repair. -Calibration Error = Call service to schedule a repair. +SRSDG 16 = [21] -Title = Calibration Error +Title = DG POST: Drain Line Vol Cal Message = Call service to schedule a repair. -Calibration Error = Call service to schedule a repair. +SRSDG 936 = [22] -Title = Calibration Error +Title = DG POST: Reservoir Vol Cal Message = Call service to schedule a repair. -Calibration Error = Call service to schedule a repair. +SRSDG 935 = [23] -Title = Calibration Error +Title = DG POST: Acid Conc Cal Message = Call service to schedule a repair. -Calibration Error = Call service to schedule a repair. +SRSDG 934 = [24] -Title = Calibration Error +Title = DG POST: Bicarb Conc Cal Message = Call service to schedule a repair. -Calibration Error = Call service to schedule a repair. +SRSDG 933 = [25] -Title = Calibration Error +Title = DG POST: Acc Cal Message = Call service to schedule a repair. -Calibration Error = Call service to schedule a repair. +SRSDG 817 = [26] -Title = Calibration Error +Title = HD POST: Acc Cal Message = Call service to schedule a repair. -Calibration Error = Call service to schedule a repair. [27] -Title = BLD Sensor Error -Message = Call service to schedule a repair. -BLD Sensor Error = Call service to schedule a repair. +Title = Process: Pre-Tx Wet Self-Test +Message = Self-test detected has a problem with the blood leak sensor\n- Check cartridge installation on to machine\n- If problem persists terminate pre-treatment and restart with a new cartridge. [28] -Title = FPGA Error +Title = DG Fault: Conductivity RTD Comm Message = Call service to schedule a repair. -FPGA Error = Call service to schedule a repair. +SRSDG 864 = [29] -Title = Calibration Error +Title = HD POST: SP DAC Cal Message = Call service to schedule a repair. -Calibration Error = Call service to schedule a repair. [30] -Title = Machine Error +Title = HD Fault: SW Invalid State Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. [31] -Title = Blood Pump Error +Title = HD Fault: BP Current Message = Call service to schedule a repair. -Blood Pump Error = Call service to schedule a repair. [32] -Title = Blood Pump Error +Title = HD Fault: BP Speed Message = Call service to schedule a repair. -Blood Pump Error = Call service to schedule a repair. [33] -Title = Blood Pump Error +Title = HD Fault: BP Direction Message = Call service to schedule a repair. -Blood Pump Error = Call service to schedule a repair. [34] -Title = Blood Pump Error -Message = Call service to schedule a repair. -Blood Pump Error = Call service to schedule a repair. +Title = HD Fault: BP Rotor +Message = Blood pump rotor failure.\n- Check the pump rotor for secure connection. [35] -Title = Dialysate Pump Error +Title = HD Fault: DPi Current Message = Call service to schedule a repair. -Dialysate Pump Error = Call service to schedule a repair. [36] -Title = Dialysate Pump Error +Title = HD Fault: DPi Speed Message = Call service to schedule a repair. -Dialysate Pump Error = Call service to schedule a repair. [37] -Title = Dialysate Pump Error +Title = HD Fault: DPi Direction Message = Call service to schedule a repair. -Dialysate Pump Error = Call service to schedule a repair. [38] -Title = Dialysate Pump Error -Message = Call service to schedule a repair. -Dialysate Pump Error = Call service to schedule a repair. +Title = HD Fault: DPi Rotor +Message = Dialysate in pump rotor failure.\n- Check the pump rotor for secure connection. [39] -Title = Dialysate Pump Error +Title = HD Fault: DPo Current Message = Call service to schedule a repair. -Dialysate Pump Error = Call service to schedule a repair. [40] -Title = Dialysate Pump Error +Title = HD Fault: DPo Speed Message = Call service to schedule a repair. -Dialysate Pump Error = Call service to schedule a repair. [41] -Title = Dialysate Pump Error +Title = HD Fault: DPo Direction Message = Call service to schedule a repair. -Dialysate Pump Error = Call service to schedule a repair. [42] -Title = Dialysate Pump Error -Message = Call service to schedule a repair. -Dialysate Pump Error = Call service to schedule a repair. +Title = HD Fault: DPo Rotor +Message = Dialysate out pump rotor failure.\n- Check the pump rotor for secure connection. [43] -Title = FPGA Error +Title = DG Fault: Iso ADC Comm Message = Call service to schedule a repair. -FPGA Error = Call service to schedule a repair. +SRSDG 954 = [44] -Title = Machine Error +Title = HD Fault: UI Comm Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. [45] -Title = Machine Error +Title = HD Fault: CAN CRC Com Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. [46] -Title = Machine Error +Title = HD Fault: CAN ACK UI Com Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. [47] -Title = Ultrafiltration Error +Title = HD Fault: UF Rate Range Err Message = Call service to schedule a repair. -Ultrafiltration Error = Call service to schedule a repair. [48] -Title = Ultrafiltration Error +Title = HD Fault: UF Rate Tare Err Message = Call service to schedule a repair. -Ultrafiltration Error = Call service to schedule a repair. [49] -Title = Machine Error +Title = HD Fault: FPGA Com Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. [50] -Title = Machine Error +Title = DG Fault: Valve Control Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. +SRSDG 26 = [51] -Title = Blood Pump Error +Title = HD Fault: BP Speed Message = Call service to schedule a repair. -Blood Pump Error = Call service to schedule a repair. [52] -Title = Dialysate Pump Error +Title = HD Fault: DPi Speed Message = Call service to schedule a repair. -Dialysate Pump Error = Call service to schedule a repair. [53] -Title = Dialysate Pump Error +Title = HD Fault: DPo Speed Message = Call service to schedule a repair. -Dialysate Pump Error = Call service to schedule a repair. [54] -Title = Machine Error +Title = HD Fault: Critical Data Err Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. [55] -Title = Machine Error +Title = DG Fault: Critical Data Err Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. +SRSDG 921 = [56] -Title = Machine Error +Title = HD Fault: Acc Com Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. [57] -Title = Machine Error +Title = DG Fault: Acc Com Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. +SRSDG 869 +SRSDG 870 = [58] -Title = Valve Error +Title = HD Fault: Valve Home Message = Call service to schedule a repair. -Valve Error = Call service to schedule a repair. [59] -Title = Valve Error +Title = HD Fault: Valve Transition Err Message = Call service to schedule a repair. -Valve Error = Call service to schedule a repair. [60] -Title = Valve Error +Title = HD Fault: Valve Control Message = Call service to schedule a repair. -Valve Error = Call service to schedule a repair. [61] -Title = Valve Error +Title = HD Fault: Valve Current Message = Call service to schedule a repair. -Valve Error = Call service to schedule a repair. [62] -Title = Valve Error +Title = HD Fault: Valve Position Message = Call service to schedule a repair. -Valve Error = Call service to schedule a repair. [63] -Title = FPGA Error +Title = HD Fault: BLD Com Message = Call service to schedule a repair. -FPGA Error = Call service to schedule a repair. [64] -Title = Barometric Pressure Error +Title = DG Fault: Baro Range Message = Call service to schedule a repair. -Barometric Pressure Error = Call service to schedule a repair. +SRSDG 874 = [65] -Title = Machine Error -Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. +Title = Loss of DG Comm (Reject) +Message = Communication failure with Dialysis Generator.\n-Treatment must be terminated.\n- Ensure all cords are securely connected. [66] -Title = Machine Error +Title = HD POST: BLD Config Set Point Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. [67] -Title = Self Test Error -Message = Call service to schedule a repair. -Self Test Error = Call service to schedule a repair. +Title = Process: Pre-Tx Remove Cartridge +Message = Cartridge has been detected.\n- Open door\n- Remove cartridge\n- Close door\n- Resume [68] -Title = Dialysate Recirculation Error -Message = Dialysate has recirculated for too long. -Dialysate Recirculation Error = Dialysate has recirculated for too long. +Title = Dial. Gen: Dialysate not ready +Message = Dialysate is not yet ready.\n- Treatment is paused and will be ready to resume when dialysate is ready for use. [69] -Title = Self-Test Error +Title = HD POST: BLD Cal Message = Call service to schedule a repair. -Self-Test Error = Call service to schedule a repair. [70] -Title = Self Test Error -Message = Call service to schedule a repair. -Self Test Error = Call service to schedule a repair. +Title = Process: Pre-Tx Remove Cartridge +Message = Cartridge has been detected.\n- Open door\n- Remove cartridge\n- Close door\n- Resume [71] -Title = Self Test Error -Message = Call service to schedule a repair. -Self Test Error = Call service to schedule a repair. +Title = Process: Pre-Tx Remove Cartridge +Message = Cartridge has been detected.\n- Open door\n- Remove cartridge\n- Close door\n- Resume [72] -Title = No load cell data received -Message = Call service to schedule a repair. -No load cell data received = Call service to schedule a repair. +Title = Loss of DG Comm (LC) +Message = Communication failure with Dialysis Generator.\n-Treatment must be terminated.\n- Ensure all cords are securely connected. [73] -Title = No dialysate temperature data received -Message = Call service to schedule a repair. -No dialysate temperature data received = Call service to schedule a repair. +Title = Loss of DG Comm (TDI/TRO) +Message = Communication failure with Dialysis Generator.\n-Treatment must be terminated.\n- Ensure all cords are securely connected. [74] -Title = UV Reactor Error +Title = DG Fault: UVi On No Flow Message = Call service to schedule a repair. -UV Reactor Error = Call service to schedule a repair. +SRSDG 600 = [75] -Title = Self Test Error +Title = HD Fault: Syringe DAC Message = Call service to schedule a repair. -Self Test Error = Call service to schedule a repair. [76] -Title = Machine Error +Title = HD Fault: Voltage Monitor Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. [77] -Title = Machine Error +Title = DG Fault: Voltage Monitor Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. +SRSDG 46 +SRSDG 866 +SRSDG 1088 = [78] -Title = Syringe Pump Error +Title = HD Fault: Syringe Pump Enc Dir Message = Call service to schedule a repair. -Syringe Pump Error = Call service to schedule a repair. [79] -Title = Syringe Pump Error +Title = HD Fault: Syringe Pump Drv Dir Message = Call service to schedule a repair. -Syringe Pump Error = Call service to schedule a repair. [80] -Title = Syringe Pump Error +Title = HD Fault: Syringe Pump Driver Message = Call service to schedule a repair. -Syringe Pump Error = Call service to schedule a repair. [81] -Title = Syringe Pump Error +Title = HD Fault: Syringe Pump OT Message = Call service to schedule a repair. -Syringe Pump Error = Call service to schedule a repair. [82] -Title = Syringe Pump Error +Title = HD Fault: Syringe Pump DAC Err Message = Call service to schedule a repair. -Syringe Pump Error = Call service to schedule a repair. [83] -Title = Syringe Pump Error +Title = HD Fault: Syringe Pump On Err Message = Call service to schedule a repair. -Syringe Pump Error = Call service to schedule a repair. [84] -Title = RTC Error +Title = DG POST: HD RTC Time Message = Call service to schedule a repair. -RTC Error = Call service to schedule a repair. +SRSDG 815 = [85] -Title = Pump Track Lever Not Fully Latched -Message = Open front door and pull pump track lever all the way down. -Pump Track Lever Not Fully Latched = Open front door and pull pump track lever all the way down. +Title = Blood Stop: Cartridge Lever Open +Message = Cartridge Lock Lever is not closed.\n- Open front door and push lever all the way down.\n- Close door and press RESUME button to continue. [86] -Title = RTC Error +Title = HD POST: HD RTC Time Message = Call service to schedule a repair. -RTC Error = Call service to schedule a repair. [87] -Title = Calibration Error +Title = DG POST: Heat Cal Message = Call service to schedule a repair. -Calibration Error = Call service to schedule a repair. +SRSDG 929 = [88] -Title = Concentrate Pumps Error +Title = DG Fault: CP1 CP2 Speed Range Message = Call service to schedule a repair. -Concentrate Pumps Error = Call service to schedule a repair. [89] -Title = UV Reactor Error +Title = DG Fault: UVo On No Flow Message = Call service to schedule a repair. -UV Reactor Error = Call service to schedule a repair. +SRSDG 599 = [90] -Title = FPGA Error +Title = DG Fault: LC A1/B1 Comm Message = Call service to schedule a repair. -FPGA Error = Call service to schedule a repair. +SRSDG 604 = [91] -Title = Dialysate Measurement Error -Message = Call service to schedule a repair. -Dialysate Measurement Error = Call service to schedule a repair. +Title = Loss of DG Comm (FMD) +Message = Communication failure with Dialysis Generator.\n-Treatment must be terminated.\n- Ensure all cords are securely connected. [92] -Title = Conductivity Sensors Error -Message = Call service to schedule a repair. -Conductivity Sensors Error = Call service to schedule a repair. +Title = +Message = [93] -Title = Conductivity Sensors Error +Title = DG Fault: RO Permeate Cond High Message = Call service to schedule a repair. -Conductivity Sensors Error = Call service to schedule a repair. +SRSDG 430 = [94] -Title = Pressure Sensors Error +Title = DG Fault: Pressure Sensor Range Message = Call service to schedule a repair. -Pressure Sensors Error = Call service to schedule a repair. +SRSDG 629 = [95] -Title = Watchdog Error +Title = DG Fault: WD Error Message = Call service to schedule a repair. -Watchdog Error = Call service to schedule a repair. +SRSDG 907 = [96] -Title = Inlet Water Temperature High -Message = Inlet water temperature is high.\n- Check the incoming water for issues with cold water supply. -Inlet Water Temperature High = Inlet water temperature is high.\n- Check the incoming water for issues with cold water supply. +Title = Dial. Gen: Inlet Water Temp High +Message = Inlet water temperature is high.\n- Treatment is paused\n- Check the incoming water supply. +SRSDG 410 = [97] -Title = Dialysate Fill Error -Message = Call service to schedule a repair. -Dialysate Fill Error = Call service to schedule a repair. +Title = Dial. Gen: Dialysate Cond. +Message = Dialysate conductivity is out of range.\n- Check acid and bicarb concentrate is correct and not empty. +SRSDG 397 = [98] -Title = Battery Error +Title = HD Alarm (Low): Battery Com Message = Call service to schedule a repair. -Battery Error = Call service to schedule a repair. [99] -Title = Syringe Pump Error +Title = HD Fault: Syringe Pump Stall Message = Call service to schedule a repair. -Syringe Pump Error = Call service to schedule a repair. [100] -Title = Self Test Error +Title = HD Fault: Timeout No Cart ST Message = Call service to schedule a repair. -Self Test Error = Call service to schedule a repair. [101] -Title = Self Test Error +Title = HD POST: UI-Proc Comm Message = Call service to schedule a repair. -Self Test Error = Call service to schedule a repair. [102] -Title = Self-Test Error -Message = Call service to schedule a repair. -Self-Test Error = Call service to schedule a repair. +Title = Cleaning: Tpo THD Temp Delta +Message = Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists call service to schedule a repair. +SRSDG 856 +SRSDG 930 = [103] -Title = Machine Error +Title = HD POST: Cal NVRAM CRC Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. [104] -Title = Air Trap Error +Title = HD Fault: Air Trap Sensor Message = Call service to schedule a repair. -Air Trap Error = Call service to schedule a repair. [105] -Title = Machine Error +Title = DG POST: Cal NVRAM CRC Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. +SRSDG 608 = [106] -Title = Calibration Error +Title = DG POST: Flow Sensor Cal Message = Call service to schedule a repair. -Calibration Error = Call service to schedule a repair. +SRSDG 820 +SRSDG 821 +SRSDG 1087 = [107] -Title = Machine Error +Title = DG Fault: DG Restarted Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. [108] -Title = Syringe Pump Error +Title = HD Fault: Syringe Pump ADC Com Message = Call service to schedule a repair. -Syringe Pump Error = Call service to schedule a repair. [109] -Title = Syringe Pump Error +Title = HD Fault: Syringe Pump Vol Message = Call service to schedule a repair. -Syringe Pump Error = Call service to schedule a repair. [110] -Title = Syringe Pump Error +Title = HD Fault: Syringe Pump Speed Message = Call service to schedule a repair. -Syringe Pump Error = Call service to schedule a repair. [111] -Title = Syringe Pump Error +Title = HD Fault: Syringe Pump Speed Message = Call service to schedule a repair. -Syringe Pump Error = Call service to schedule a repair. [112] -Title = FPGA Error +Title = DG Fault: LC A2/B2 Comm Message = Call service to schedule a repair. -FPGA Error = Call service to schedule a repair. +SRSDG 953 = [113] -Title = Drain Pump Error +Title = DG Fault: DRP Current Message = Call service to schedule a repair. -Drain Pump Error = Call service to schedule a repair. +SRSDG 890 = [114] -Title = Air Bubble Detector Error -Message = Call service to schedule a repair. -Air Bubble Detector Error = Call service to schedule a repair. +Title = Process: Pre-Tx Wet Self-Test +Message = Self-test has detected a problem with the air bubble sensor\n- Check cartridge installation on to machine\n- If problem persists terminate pre-treatment and restart with a new cartridge. [115] -Title = Dialysate Temperature Error +Title = DG Fault: Temp Sensor Range Message = Call service to schedule a repair. -Dialysate Temperature Error = Call service to schedule a repair. +SRSDG 224 = [116] -Title = Dialysate Temperature Error -Message = Call service to schedule a repair. -Dialysate Temperature Error = Call service to schedule a repair. +Title = HD Alarm (Low): SD-Card Error +Message = SD-Card Failure \n- Power cycle the system.\n- Call service to schedule a repair if problem persists [117] -Title = Machine Error -Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. +Title = Loss of HD Comm (HD ACK) +Message = Communication failure with Dialysis Generator.\n-Treatment must be terminated.\n- Ensure all cords are securely connected. +SRSDG 909 = [118] -Title = RTC Error +Title = DG Fault: RTC Config Message = Call service to schedule a repair. -RTC Error = Call service to schedule a repair. +SRSDG 43 = [119] -Title = RTC Error +Title = DG Alarm (Low): RTC Bat Low Message = Call service to schedule a repair. -RTC Error = Call service to schedule a repair. +SRSDG 908 = [120] -Title = Pre Treament Error -Message = Call service to schedule a repair. -Pre Treament Error = Call service to schedule a repair. +Title = Process: Pre-Tx Wet Self-Test +Message = Self-test has detected a bubble in the venous bubble detector\n- The cartridge should be primed\n- Check cartridge installation on to machine\n- If problem persists terminate pre-treatment and restart with a new cartridge. [121] -Title = Heaters Error +Title = DG Fault: Prim Heater Lg Control Message = Call service to schedule a repair. -Heaters Error = Call service to schedule a repair. +SRSDG 611 = [122] -Title = Heaters Error +Title = DG Fault: Prim Heater Sm Control Message = Call service to schedule a repair. -Heaters Error = Call service to schedule a repair. +SRSDG 612 = [123] -Title = Heaters Error +Title = DG Fault: Trimmer Heater Control Message = Call service to schedule a repair. -Heaters Error = Call service to schedule a repair. +SRSDG 613 = [124] -Title = Blood Stagnant -Message = Blood has sat too long in the blood tubing set. No rinseback allowed. -Blood Stagnant = Blood has sat too long in the blood tubing set. No rinseback allowed. +Title = Blood Stop: Blood Clot Risk +Message = Blood pump has been off for too long.\n- Treament must be terminated. Blood clot risk.\n-\n- NO RINSEBACK ALLOWED. [125] -Title = Blood Stagnant -Message = Blood has sat too long in the blood tubing set. Treatment must end. -Blood Stagnant = Blood has sat too long in the blood tubing set. Treatment must end. +Title = Blood Stop: Blood Clot Risk +Message = Blood pump has been off for too long.\n- Treament must be terminated. Blood clot risk.\n-\n- NO RINSEBACK ALLOWED. [126] -Title = Dialyzer Blood Leak Detected +Title = Blood Stop: Dialyzer Blood Leak Message = A blood leak has been detected. Treatment must end. -Dialyzer Blood Leak Detected = A blood leak has been detected. Treatment must end. [127] -Title = Venous Pressure Low +Title = Blood Stop: Venous Pres. Low Message = Venous pressure is low.\n- Check to be sure your blue venous connections are secure.\n- Check that your venous access is connected and secured properly. -Venous Pressure Low = Venous pressure is low.\n- Check to be sure your blue venous connections are secure.\n- Check that your venous access is connected and secured properly. [128] -Title = Venous Air Bubble Detected -Message = Venous air bubble detected.\n- Check for air bubbles in the venous line.\n- If bubbles are present, tap the tubing to move the bubbles up to the air trap.\n- If bubbles cannot be removed, treatment must end. -Venous Air Bubble Detected = Venous air bubble detected.\n- Check for air bubbles in the venous line.\n- If bubbles are present, tap the tubing to move the bubbles up to the air trap.\n- If bubbles cannot be removed, treatment must end. +Title = Blood Stop: Venous Air Bubble +Message = Venous air bubble detected indicating failure of air trap control system.\n- Treatment must be terminated without option for rinseback.\n- Check access for dislodgement [129] -Title = Venous Air Bubble Detected During Rinseback -Message = Venous air bubble detected.\n- Check for air bubbles in the venous line.\n- If bubbles are present, tap the tubing to move the bubbles up to the air trap.\n- If bubbles cannot be removed, treatment must end. -Venous Air Bubble Detected During Rinseback = Venous air bubble detected.\n- Check for air bubbles in the venous line.\n- If bubbles are present, tap the tubing to move the bubbles up to the air trap.\n- If bubbles cannot be removed, treatment must end. +Title = Blood Stop: Venous Air Bubble +Message = Venous air bubble detected indicating failure of air trap control system.\n- Treatment must be terminated without option for rinseback.\n- Check access for dislodgement [130] -Title = Venous Pressure High +Title = Blood Stop: Venous Pres. High Message = Venous pressure is high.\n- Check for access or patient discomfort.\n- Resolve access issue if applicable.\n- Check that there are no kinks or clots in the tubing.\n- Unkink the lines if applicable.\n- End treatment and do not return blood if clots are present. -Venous Pressure High = Venous pressure is high.\n- Check for access or patient discomfort.\n- Resolve access issue if applicable.\n- Check that there are no kinks or clots in the tubing.\n- Unkink the lines if applicable.\n- End treatment and do not return blood if clots are present. [131] -Title = Arterial Pressure Low +Title = Blood Stop: Arterial Pres. Low Message = Arterial pressure is low.\n- Check that the access is properly connected and secured.\n- Resolve access issue if applicable.\n- Check to be sure the red arterial connections are secure.\n- Check that there are no kinks or clots in the tubing.\n- Unkink lines if applicable.\n- End treatment and do not return blood if clots are present. -Arterial Pressure Low = Arterial pressure is low.\n- Check that the access is properly connected and secured.\n- Resolve access issue if applicable.\n- Check to be sure the red arterial connections are secure.\n- Check that there are no kinks or clots in the tubing.\n- Unkink lines if applicable.\n- End treatment and do not return blood if clots are present. [132] -Title = Arterial Pressure High +Title = Blood Stop: Arterial Pres. High Message = Arterial pressure is high.\n- Check that the access is properly connected and secured.\n- Resolve access issue if applicable.\n- Check to be sure your red arterial connections are secure.\n- Check that there are no kinks or clots in the tubing.\n- Unkink lines if applicable.\n- End treatment and do not return blood if clots are present. -Arterial Pressure High = Arterial pressure is high.\n- Check that the access is properly connected and secured.\n- Resolve access issue if applicable.\n- Check to be sure your red arterial connections are secure.\n- Check that there are no kinks or clots in the tubing.\n- Unkink lines if applicable.\n- End treatment and do not return blood if clots are present. [133] -Title = Fluid Leak in DG -Message = Fluid leak detected in Dialysate Generation Delivery Device. -Fluid Leak in DG = Fluid leak detected in Dialysate Generation Delivery Device. +Title = DG Fault: Fluid Leak in DG +Message = Fluid leak detected in Dialysate Generation Delivery Device.\n-Treatment must be terminated.\n- Shut off water source and disconnect water and electrical connections from system.\n- Call service to schedule a repair. +SRSDG 328 = [134] -Title = Fluid Leak in HD -Message = Fluid leak detected in Hemodialysis Delivery device.\n- Identify and correct the cause of the spill.\n- Clean up the spill with a clean paper towel.\n- Resume treatment. -Fluid Leak in HD = Fluid leak detected in Hemodialysis Delivery device.\n- Identify and correct the cause of the spill.\n- Clean up the spill with a clean paper towel.\n- Resume treatment. +Title = Blood Stop: Fluid Leak in HD +Message = Fluid leak detected in Hemodialysis Delivery device.\n- If in treatment BLOOD STOPPED.\n-Identify and correct the cause of the spill.\n- Clean up the spill and dry leak sensor.\n- If in treatment resume treatment. [135] -Title = Excessive Acceleration Detected in the HD +Title = Blood Stop: HD Shock Detected Message = Excessive movement detected with Hemodialysis Delivery device.\n- Confirm the device is stationary and level before continuing. -Excessive Acceleration Detected in the HD = Excessive movement detected with Hemodialysis Delivery device.\n- Confirm the device is stationary and level before continuing. [136] -Title = Excessive Acceleration Detected in the DG -Message = Excessive movement detected with Dialysis Generation device.\n- Confirm the device is stationary and level before continuing. -Excessive Acceleration Detected in the DG = Excessive movement detected with Dialysis Generation device.\n- Confirm the device is stationary and level before continuing. +Title = Dial. Gen: Shock-Vibration +Message = Excessive movement detected with Dialysis Generation device.\n- Treatment is paused.\n- Confirm the device is stationary and level before continuing. +SRSDG 327 = [137] -Title = Excessive Tilt Detected in the Hemodialysis Device +Title = Blood Stop: HD Tilted Message = Excessive tilt detected with Hemodialysis Delivery device.\n- Confirm the device is stationary and level before continuing -Excessive Tilt Detected in the Hemodialysis Device = Excessive tilt detected with Hemodialysis Delivery device.\n- Confirm the device is stationary and level before continuing [138] -Title = Excessive Tilt Detected in the Dialysate Generation Device -Message = Excessive tilt detected with Dialysis Generation device.\n-Confirm the device is stationary and level before continuing. -Excessive Tilt Detected in the Dialysate Generation Device = Excessive tilt detected with Dialysis Generation device.\n-Confirm the device is stationary and level before continuing. +Title = Dial. Gen: Tilt +Message = Excessive tilt detected with Dialysis Generation device.\n- Treatment is paused.\n-Confirm the device is stationary and level before continuing. +SRSDG 326 = [139] -Title = HD Power Lost +Title = Loss of AC Power Message = Power has been lost. Check all electrical connections.\n- The display and CPU will run off of the battery until power returns. -HD Power Lost = Power has been lost. Check all electrical connections.\n- The display and CPU will run off of the battery until power returns. [140] -Title = Communication Failure with Dialysate Generator -Message = Communication failure with Dialysis Generator.\n- Ensure all cords are securely connected. -Communication Failure with Dialysate Generator = Communication failure with Dialysis Generator.\n- Ensure all cords are securely connected. +Title = Loss of DG Comm (Timeout) +Message = Communication failure with Dialysis Generator.\n-Treatment must be terminated.\n- Ensure all cords are securely connected. [141] -Title = Air Trap Unable to Fill -Message = Failure to fill the Air Trap.\n- Check the air trap vent line and the transducer protector.\n- If the transducer protector is wet, replace it. -Air Trap Unable to Fill = Failure to fill the Air Trap.\n- Check the air trap vent line and the transducer protector.\n- If the transducer protector is wet, replace it. +Title = Blood Stop: Air Trap Fill +Message = Failure to fill the Air Trap.\n- Treatment must be terminated without option for rinseback.\n- Check access for dislodgement [142] -Title = Blood Pump Occlusion Detected +Title = Blood Stop: Blood Pump Occlusion Message = Occlusion detected after the blood pump.\n- Check for clots or kinks around the dialyzer and in the venous line.\n- Resolve access issue if applicable.\n- End treatment and do not return blood if clots are present.\n- Check for access or patient discomfort.\n- Unkink the lines if applicable. -Blood Pump Occlusion Detected = Occlusion detected after the blood pump.\n- Check for clots or kinks around the dialyzer and in the venous line.\n- Resolve access issue if applicable.\n- End treatment and do not return blood if clots are present.\n- Check for access or patient discomfort.\n- Unkink the lines if applicable. [143] -Title = Dialysate Temperature Error +Title = DG Fault: TRo TDi Delta Message = Call service to schedule a repair. -Dialysate Temperature Error = Call service to schedule a repair. +SRSDG 912 = [144] -Title = Cleaning Mode Inlet Water Conductivity Too High -Message = Inlet water conductivity too high.\n- Check the incoming water for issues with cold water supply. -Cleaning Mode Inlet Water Conductivity Too High = Inlet water conductivity too high.\n- Check the incoming water for issues with cold water supply. +Title = Cleaning: Inlet Water Cond High +Message = Cleaning Mode Inlet water conductivity too high.\n- Cleaning mode process has terminated \n- Check inlet water before restarting cleaning mode. +SRSDG 1066 +SRSDG 1054 +SRSDG 970 = [145] -Title = Acid Concentrate Conductivity Out of Range -Message = Dialysate conductivity is out of range.\n- Check correct acid concentrate is connected. -Acid Concentrate Conductivity Out of Range = Dialysate conductivity is out of range.\n- Check correct acid concentrate is connected. +Title = Dial. Gen: Acid Conc. Cond. +Message = Acid concentrate conductivity during prime is out of range.\n- Check correct acid concentrate is connected and full.\n- Resume to reprime concentrate. +SRSDG 846 = [146] -Title = Self-Test Error +Title = DG POST: DG RTC Timer Message = Call service to schedule a repair. -Self-Test Error = Call service to schedule a repair. +SRSDG 312 = [147] -Title = Dialysate Conductivity Error -Message = Call service to schedule a repair. -Dialysate Conductivity Error = Call service to schedule a repair. +Title = Dial. Gen: Dialysate not ready +Message = Dialysate is not yet ready.\n- Treatment is paused and will be ready to resume when dialysate is ready for use. +SRSDG 398 = [148] -Title = Cleaning Mode Inlet Water Temperature Too High -Message = Cleaning Mode Inlet water temperature too high.\n- Check the incoming water for issues with cold water supply. -Cleaning Mode Inlet Water Temperature Too High = Cleaning Mode Inlet water temperature too high.\n- Check the incoming water for issues with cold water supply. +Title = Cleaning: Inlet Water Temp High +Message = Cleaning Mode Inlet water temperature too high.\n- Cleaning mode process has terminated \n- Check inlet water before restarting cleaning mode. +SRSDG 1065 +SRSDG 1053 +SRSDG 969 = [149] -Title = Watchdog Error +Title = HD Fault: WD Error Message = Call service to schedule a repair. -Watchdog Error = Call service to schedule a repair. [150] -Title = Inlet Water Conductivity High -Message = Inlet water conductivity is high.\n- Check the incoming water for issues. -Inlet Water Conductivity High = Inlet water conductivity is high.\n- Check the incoming water for issues. +Title = Dial. Gen: Inlet Water Cond High +Message = Inlet water conductivity is high.\n- Treatment is paused\n- Check the incoming water supply. +SRSDG 391 = [151] -Title = Inlet Water Conductivity Low -Message = Inlet water conductivity is low.\n- Check the incoming water for issues. -Inlet Water Conductivity Low = Inlet water conductivity is low.\n- Check the incoming water for issues. +Title = Dial. Gen: Inlet Water Cond Low +Message = Inlet water conductivity is low.\n- Treatment is paused\n- Check the incoming water supply. +SRSDG 826 = [152] -Title = Inlet Water Pressure Low -Message = Inlet water pressure is low.\n- Check the incoming water supply. -Inlet Water Pressure Low = Inlet water pressure is low.\n- Check the incoming water supply. +Title = Dial. Gen: Inlet Water Pres Low +Message = Inlet water pressure is low.\n- Treatment is paused\n- Check the incoming water supply. +SRSDG 417 = [153] -Title = Prime Complete -Message = Prime of the bloodlines is complete. -Prime Complete = Prime of the bloodlines is complete. +Title = Process: Pre-Tx Terminated +Message = Pre-Treatment timeout.\n- Patient was not connected to device\n- Pre-Treatment has been terminated\n- Proceed to end treatment to remove cartridge from system [154] -Title = Cleaning Mode Inlet Water Conductivity Low -Message = Cleaning Mode Inlet water conductivity is low.\n- Check the incoming water. -Cleaning Mode Inlet Water Conductivity Low = Cleaning Mode Inlet water conductivity is low.\n- Check the incoming water. +Title = Cleaning: Inlet Water Cond Low +Message = Cleaning Mode Inlet water conductivity too low.\n- Cleaning mode process has terminated \n- Check inlet water before restarting cleaning mode. +SRSDG 1067 +SRSDG 1055 +SRSDG 971 = [155] -Title = No reservoir data received -Message = Call service to schedule a repair. -No reservoir data received = Call service to schedule a repair. +Title = Loss of DG Comm (Reservoir) +Message = Communication failure with Dialysis Generator.\n-Treatment must be terminated.\n- Ensure all cords are securely connected. [156] -Title = No DG op mode received -Message = Call service to schedule a repair. -No DG op mode received = Call service to schedule a repair. +Title = Loss of DG Comm (Op Mode) +Message = Communication failure with Dialysis Generator.\n-Treatment must be terminated.\n- Ensure all cords are securely connected. [157] -Title = Chemical Disinfection Error -Message = Ensure the acid is connected to the bicarb line -Chemical Disinfection Error = Ensure the acid is connected to the bicarb line +Title = Cleaning: Chem Disinf PAA Prime +Message = Unable to sense proper chemical disinfectant.\n- Cleaning mode process has terminated.\n- Check that proper chemical disinfectant is connected to the bicarb port.\n- Check chemical disinfectant bottle is not empty. +SRSDG 988 = [158] -Title = Inlet water temperature low -Message = Inlet water temperature is low.\n- Check the incoming water supply. -Inlet water temperature low = Inlet water temperature is low.\n- Check the incoming water supply. +Title = Dial. Gen: Inlet Water Temp Low +Message = Inlet water temperature is low.\n- Treatment is paused\n- Check the incoming water supply. +SRSDG 408 = [159] -Title = Chemical Disinfect Flush -Message = Remove Acid Bottle and Close Concentrate Cap. -Chemical Disinfect Flush = Remove Acid Bottle and Close Concentrate Cap. +Title = Cleaning: Chem Disinf Connect Cap +Message = Remove chemical disinfectant connection and close cap. +SRSDG 1044 = [160] -Title = Blood Pump Speed High -Message = Blood pump failure.\n- Check the pump rotor for secure connection. -Blood Pump Speed High = Blood pump failure.\n- Check the pump rotor for secure connection. +Title = HD Fault: BP Rotor Max Speed +Message = Call service to schedule a repair. [161] -Title = Machine Error +Title = DG Fault: HD-DG Comm Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. +SRSDG 122 = [162] -Title = FPGA Error +Title = DG Fault: Proc-FPGA Clock Message = Call service to schedule a repair. -FPGA Error = Call service to schedule a repair. +SRSDG 867 = [163] -Title = Ultrafiltration Measurement Error -Message = Ultrafiltration error. -Ultrafiltration Measurement Error = Ultrafiltration error. +Title = Dial. Gen: UF Rate Check +Message = Ultrafiltration control detected and incorrect rate.\n- This can be caused by excessive movement of system (shock/vibration)\n- Check system is stable and level\n- Resume and if problem persists call service to schedule a repair. [164] -Title = Ultrafiltration Measurement Error -Message = Ultrafiltration error. -Ultrafiltration Measurement Error = Ultrafiltration error. +Title = Dial. Gen: UF Rate Check +Message = Ultrafiltration control detected and incorrect rate.\n- This can be caused by excessive movement of system (shock/vibration)\n- Check system is stable and level\n- Resume and if problem persists call service to schedule a repair. [165] -Title = Rinseback Timeout -Message = Maximum Rinseback time exceeded. Rinseback must end. -Rinseback Timeout = Maximum Rinseback time exceeded. Rinseback must end. +Title = Blood Stop: Blood Clot Risk +Message = Blood pump has been off for too long.\n- Treament must be terminated. Blood clot risk.\n-\n- NO RINSEBACK ALLOWED. [166] -Title = Recirculation Timeout -Message = Maximum Recirculation time exceeded. Treatment must end. -Recirculation Timeout = Maximum Recirculation time exceeded. Treatment must end. +Title = +Message = [167] -Title = Door Open -Message = Hemodialysis Delivery device door open.\n - Close open HD door\n - Press RESUME button -Door Open = Hemodialysis Delivery device door open.\n - Close open HD door\n - Press RESUME button +Title = Blood Stop: Door Open +Message = Device door is open.\n - Close door and press RESUME button to continue. [168] -Title = Dialysate Recirculation Error -Message = Dialysate recirculation error. -Dialysate Recirculation Error = Dialysate recirculation error. +Title = +Message = [169] -Title = Dialysate Generation Error +Title = DG Fault: Dialysate Flow Sens Rg Message = Call service to schedule a repair. -Dialysate Generation Error = Call service to schedule a repair. +SRSDG 643 = [170] -Title = Syringe Empty -Message = Heparin syringe empty.\n- Option to resume treatment without heparin. -Syringe Empty = Heparin syringe empty.\n- Option to resume treatment without heparin. +Title = Heparin Syringe Empty +Message = Heparin syringe empty.\n- Treatment will continue\n- If additional heparin is required to complete treatment admisinster manually [171] -Title = Heparin Occlusion -Message = Heparin pump occlusion detected. Check heparin line is unclamped and there are no kinks in the heparin line. -Heparin Occlusion = Heparin pump occlusion detected. Check heparin line is unclamped and there are no kinks in the heparin line. +Title = Process: Pre-Tx Hep. Pump Occ. +Message = Heparin pump occlusion detected.\n- Check heparin line is unclamped.\n- Check there are no kinks in the heparin line. [172] -Title = Not Enough Heparin +Title = Process: Pre-Tx Not Enough Hep. Message = Not enough heparin is available for treatment. Check if syringe pump is touching syringe plunger. If syringe pump is touching syringe plunger, end treatment. If syringe pump is not touching syringe plunger, reload syringe with enough heparin. -Not Enough Heparin = Not enough heparin is available for treatment. Check if syringe pump is touching syringe plunger. If syringe pump is touching syringe plunger, end treatment. If syringe pump is not touching syringe plunger, reload syringe with enough heparin. [173] -Title = RTC Error +Title = HD Fault: RTC Config Message = Call service to schedule a repair. -RTC Error = Call service to schedule a repair. [174] -Title = Self-Test Error +Title = HD POST: HD RTC Timer Message = Call service to schedule a repair. -Self-Test Error = Call service to schedule a repair. [175] -Title = Blood Pump Error -Message = Blood pump failure. \n- Check the pump rotor for secure connection. -Blood Pump Error = Blood pump failure. \n- Check the pump rotor for secure connection. +Title = HD Fault: Pump Commutation Err +Message = Call service to schedule a repair. [176] -Title = Dialysate Temperature Error -Message = Call service to schedule a repair. -Dialysate Temperature Error = Call service to schedule a repair. +Title = +Message = [177] -Title = Machine Error +Title = DG Fault: Software Invalid State Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. +SRSDG 919 = [178] -Title = Communication Failure +Title = HD Fault: UI-Proc Comm Message = Call service to schedule a repair. -Communication Failure = Call service to schedule a repair. + = SRSUI 1066 [179] -Title = Communication Failure +Title = DG Fault: FPGA Com Message = Call service to schedule a repair. -Communication Failure = Call service to schedule a repair. +SRSDG 605 = [180] -Title = RO Flow Error +Title = DG Fault: RO Flow Sensor Range Message = Call service to schedule a repair. -RO Flow Error = Call service to schedule a repair. +SRSDG 883 = [181] -Title = Ultrafiltration Measurement Error +Title = DG Fault: Tare Out of Range Message = Call service to schedule a repair. -Ultrafiltration Measurement Error = Call service to schedule a repair. +SRSDG 849 +SRSDG 838 = [182] -Title = Ultrafiltration Measurement Error +Title = DG POST: LC Cal Message = Call service to schedule a repair. -Ultrafiltration Measurement Error = Call service to schedule a repair. +SRSDG 162 = [183] -Title = Heat Disinfection Error -Message = Call service to schedule a repair. -Heat Disinfection Error = Call service to schedule a repair. +Title = Cleaning: Invalid Resv Transfer +Message = Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists call service to schedule a repair. +SRSDG 851 = [184] -Title = UV Reactor Error +Title = DG Fault: UVi Error Message = Call service to schedule a repair. -UV Reactor Error = Call service to schedule a repair. +SRSDG 559 = [185] -Title = Fan Error +Title = DG Alarm (Low): Fan Speed Message = Fan failure.\n- Check that the fans inlets are not blocked or obstructed. -Fan Error = Fan failure.\n- Check that the fans inlets are not blocked or obstructed. +SRSDG 628 = [186] -Title = Dialysate Concentrate Pump Error +Title = DG Fault: CP1/CP2 Fault Message = Call service to schedule a repair. -Dialysate Concentrate Pump Error = Call service to schedule a repair. +SRSDG 891 = [187] -Title = Dialysate Concentrate Pump Error +Title = DG Fault: CP1 Speed Fault Message = Call service to schedule a repair. -Dialysate Concentrate Pump Error = Call service to schedule a repair. +SRSDG 905 = [188] -Title = Dialysate Concentrate Pump Error +Title = DG Fault: CP2 Speed Fault Message = Call service to schedule a repair. -Dialysate Concentrate Pump Error = Call service to schedule a repair. +SRSDG 906 = [189] -Title = Drain Pump Error +Title = DG Fault: DRP Speed Fault Message = Call service to schedule a repair. -Drain Pump Error = Call service to schedule a repair. +SRSDG 448 = [190] -Title = Drain Pump Error +Title = DG Fault: DRP Speed Not Off Message = Call service to schedule a repair. -Drain Pump Error = Call service to schedule a repair. [191] -Title = RO Flow Error +Title = DG Fault: RO Flow High Message = Call service to schedule a repair. -RO Flow Error = Call service to schedule a repair. +SRSDG 885 = [192] -Title = RO Flow Error +Title = DG Fault: RO Flow Low Message = Call service to schedule a repair. -RO Flow Error = Call service to schedule a repair. +SRSDG 945 = [193] -Title = Dialysate Temperature Error -Message = Call service to schedule a repair. -Dialysate Temperature Error = Call service to schedule a repair. +Title = +Message = [194] -Title = RO Pump Error +Title = DG Fault: RO Driver Feedback Message = Call service to schedule a repair. -RO Pump Error = Call service to schedule a repair. +SRSDG 881 = [195] -Title = RO Pump Error +Title = DG Fault: RO Pump High Pressure Message = Call service to schedule a repair. -RO Pump Error = Call service to schedule a repair. +SRSDG 925 = [196] -Title = FPGA Error +Title = DG Fault: CPi/CPo Comm Message = Call service to schedule a repair. -FPGA Error = Call service to schedule a repair. +SRSDG 955 = [197] -Title = FPGA Error +Title = DG Fault: CD1/CD2 Comm Message = Call service to schedule a repair. -FPGA Error = Call service to schedule a repair. +SRSDG 956 = [198] -Title = Heaters Error +Title = DG Fault: HP On With No Flow Message = Call service to schedule a repair. -Heaters Error = Call service to schedule a repair. +SRSDG 872 = [199] -Title = Heaters Error +Title = DG Fault: HR On With No Flow Message = Call service to schedule a repair. -Heaters Error = Call service to schedule a repair. +SRSDG 871 = [200] -Title = Thermistors Error +Title = DG Fault: Thermistor Range Message = Call service to schedule a repair. -Thermistors Error = Call service to schedule a repair. +SRSDG 178 = [201] -Title = Pre-Treatment Error -Message = Call service to schedule a repair. -Pre-Treatment Error = Call service to schedule a repair. +Title = Process: Pre-Tx Wet Self-Test +Message = Self-test has detected a problem in the dialysate flow measurement or there is a leak in the dialysate in/out lines\n- The cartridge should be primed\n- Check cartridge installation on to machine\n- If problem persists terminate pre-treatment and restart with a new cartridge. [202] -Title = Pre-Treatment Error -Message = Call service to schedule a repair. -Pre-Treatment Error = Call service to schedule a repair. +Title = Process: Pre-Tx Dry Self-Test +Message = Self-test has detected blood circuit pressure cannot be relieved\n- Check PBo connection to HD for kinks\n -Check PBo transducer protector for occlusion\n- If problem persists install a new cartridge and PBo transducer protector. [203] -Title = Pressure Sensors Error -Message = Call service to schedule a repair. -Pressure Sensors Error = Call service to schedule a repair. +Title = +Message = [204] -Title = RO Rejection Error +Title = DG Fault: RO Rejection Message = Call service to schedule a repair. -RO Rejection Error = Call service to schedule a repair. +SRSDG 429 = [205] -Title = Conductivity Sensors Error +Title = DG Fault: Cond Sensors Error Message = Call service to schedule a repair. -Conductivity Sensors Error = Call service to schedule a repair. +SRSDG 913 = [206] -Title = Dialysate Production Error +Title = DG Fault: Reservoir Fill Timeout Message = Call service to schedule a repair. -Dialysate Production Error = Call service to schedule a repair. +SRSDG 437 = [207] -Title = Dialysate Flowrate Error +Title = DG Fault: FMP Flow Rate Error Message = Call service to schedule a repair. -Dialysate Flowrate Error = Call service to schedule a repair. +SRSDG 240 = [208] -Title = Venous Occlusion Error -Message = Call service to schedule a repair. -Venous Occlusion Error = Call service to schedule a repair. +Title = Blood Stop: Venous Pres. High +Message = Venous pressure is high.\n- Check for access or patient discomfort.\n- Resolve access issue if applicable.\n- Check that there are no kinks or clots in the tubing.\n- Unkink the lines if applicable.\n- End treatment and do not return blood if clots are present. [209] -Title = Flush Mode Error -Message = Call service to schedule a repair. -Flush Mode Error = Call service to schedule a repair. +Title = Cleaning: Flush Circ Error +Message = Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists call service to schedule a repair. +SRSDG 980 = [210] -Title = Battery Error -Message = Battery pack error. -Battery Error = Battery pack error. +Title = HD Alarm (Low): Battery Fault +Message = Call service to schedule a repair. [211] -Title = Blood Stagnant -Message = Maximum time for blood stoppage has been exceeded. -Blood Stagnant = Maximum time for blood stoppage has been exceeded. +Title = Blood Stopped: Warning +Message = Blood pump is stopped.\n- Resume treatment before countdown timer expires. [212] -Title = Blood Stagnant -Message = Maximum time for blood stoppage has been exceeded. -Blood Stagnant = Maximum time for blood stoppage has been exceeded. +Title = Blood Stopped: Warning +Message = Blood pump is stopped.\n- Resume treatment before countdown timer expires. [213] -Title = Prime Complete -Message = Prime of the bloodlines is complete. -Prime Complete = Prime of the bloodlines is complete. +Title = Process: Pre-Tx Prime Complete +Message = Prime of the cartridge is complete.\n- Proceed to connect to patient. [214] -Title = Saline Bolus Error -Message = Inability to deliver saline bolus.\n- Check for kinks or clamped lines in the saline line. -Saline Bolus Error = Inability to deliver saline bolus.\n- Check for kinks or clamped lines in the saline line. +Title = +Message = [215] -Title = Rinseback Error -Message = Unable to complete Rinseback.\n- Check for kinks or clamped blood lines. -Rinseback Error = Unable to complete Rinseback.\n- Check for kinks or clamped blood lines. +Title = +Message = [216] -Title = Treatment Ended -Message = Treatment has ended -Treatment Ended = Treatment has ended +Title = Process: End of Dialysis Tx +Message = Dialysis Treatment has completed\n- Proceed to end treatment and rinseback [217] -Title = Prime Error -Message = Blood prime error. Check for kinks or clamped blood lines. -Prime Error = Blood prime error. Check for kinks or clamped blood lines. +Title = +Message = [218] -Title = Syringe Detected -Message = Remove Heparin syringe. -Syringe Detected = Remove Heparin syringe. +Title = Process: Remove Syringe +Message = Syringe not removed from machine.\n- Remove heparin syringe. [219] -Title = Syringe Removed -Message = Install Heparin syringe. -Syringe Removed = Install Heparin syringe. +Title = Blood Stop: Syringe Not Detected +Message = Heparin is needed for treatment but syringe has been removed from syringe pump.\n- Install Heparin syringe. [220] -Title = FPGA Error +Title = DG Fault: THD RTD Comm Message = Call service to schedule a repair. -FPGA Error = Call service to schedule a repair. +SRSDG 947 = [221] -Title = Saline Bag Empty -Message = Saline back appears empty.\n- Check saline bag and line and replace if saline bag is empty. -Saline Bag Empty = Saline back appears empty.\n- Check saline bag and line and replace if saline bag is empty. +Title = Blood Stop: Saline Bag Empty +Message = Saline bag appears empty.\n- Check saline bag and line and replace if saline bag is empty. [222] -Title = FPGA Error +Title = HD Fault: BP Occ Com Message = Call service to schedule a repair. -FPGA Error = Call service to schedule a repair. [223] -Title = FPGA Error +Title = HD Fault: Art. Pres. Com Message = Call service to schedule a repair. -FPGA Error = Call service to schedule a repair. [224] -Title = Treatment Stopped -Message = Treatment paused. -Treatment Stopped = Treatment paused. +Title = Blood Stopped: Treatment Pause +Message = Treatment paused by user. [225] -Title = End of Treatment -Message = Treatment has ended -End of Treatment = Treatment has ended +Title = Process: End of Treatment +Message = Dialysis Treatment has completed\n- Proceed to end treatment and rinseback [226] -Title = Prime Complete -Message = Prime of the bloodlines is complete. -Prime Complete = Prime of the bloodlines is complete. +Title = Process: Pre-Tx Priming Complete +Message = Prime of the cartridge is complete.\n- Proceed to connect to patient. [227] -Title = Maximum Prime Time Exceeded -Message = Maximum time for blood prime has been exceeded. -Maximum Prime Time Exceeded = Maximum time for blood prime has been exceeded. +Title = +Message = [228] -Title = Maximum Prime Time Exceeded -Message = Priming failure.\n- Check blood and dialysate lines for clamps and kinks. -Maximum Prime Time Exceeded = Priming failure.\n- Check blood and dialysate lines for clamps and kinks. +Title = Process: Pre-Tx Prime Timeout +Message = Blood line prime with saline timeout.\n- Check blood and dialysate lines for clamps, kinks or leaks. [229] -Title = Maximum Prime Time Exceeded -Message = Priming failure.\n- Check blood and dialysate lines for clamps and kinks. -Maximum Prime Time Exceeded = Priming failure.\n- Check blood and dialysate lines for clamps and kinks. +Title = Process: Pre-Tx Prime Timeout +Message = Dialyzer prime timeout.\n- Check blood and dialysate lines for clamps, kinks or leaks. [230] -Title = Maximum Prime Time Exceeded -Message = Priming failure.\n- Check blood and dialysate lines for clamps and kinks. -Maximum Prime Time Exceeded = Priming failure.\n- Check blood and dialysate lines for clamps and kinks. +Title = Process: Pre-Tx Prime Timeout +Message = Dialyzer prime timeout.\n- Check blood and dialysate lines for clamps, kinks or leaks. [231] -Title = Self Test Error -Message = Self Test Failure. Please ensure the disposable cartridge is completely installed and the handle moved to the down position. -Self Test Error = Self Test Failure. Please ensure the disposable cartridge is completely installed and the handle moved to the down position. +Title = Process: Pre-Tx Dry Self-Test +Message = Self-test has detected a leak in the circuit\n- Check blood line connections\n- Check dialysate line connections\n- Check PBo and PBa transducer protectors for occlusion\n- Check clamps\n- If problem persists install a new cartridge [232] -Title = Self Test Error -Message = Self Test Failure. Please ensure the disposable cartridge is completely installed and the handle moved to the down position. Check for closed clamps or kinks in the tubing. -Self Test Error = Self Test Failure. Please ensure the disposable cartridge is completely installed and the handle moved to the down position. Check for closed clamps or kinks in the tubing. +Title = Process: Pre-Tx Wet Self-Test +Message = Self-test has detected a problem in the load cell measurement or there is a leak in the dialysate in/out lines\n- The cartridge should be primed\n- Check cartridge installation on to machine\n- If problem persists terminate pre-treatment and restart with a new cartridge. [233] -Title = Pressure Sensors Error +Title = DG Fault: Baro Cal CRC Message = Call service to schedule a repair. -Pressure Sensors Error = Call service to schedule a repair. +SRSDG 964 +SRSDG 949 +SRSDG 1089 = [234] -Title = Inlet Water Pressure High -Message = Inlet water pressure is high.\n- Check the incoming water for issues. -Inlet Water Pressure High = Inlet water pressure is high.\n- Check the incoming water for issues. +Title = Dial. Gen: Inlet Water Pres High +Message = Inlet water pressure is high.\n- Treatment is paused\n- Check the incoming water supply. +SRSDG 1037 = [235] -Title = Rinseback Complete +Title = Process: Rinseback Complete Message = Rinseback has been completed. -Rinseback Complete = Rinseback has been completed. [236] -Title = New Cartridge Needed -Message = New cartridge needs to be installed. -New Cartridge Needed = New cartridge needs to be installed. +Title = Process: Pre-Tx Dry Self-Test +Message = Self-test has detected fluid in the cartridge.\n- Cartridges are single-use only\n- Install new cartridge to resume. [237] -Title = Prime Error -Message = Call service to schedule a repair. -Prime Error = Call service to schedule a repair. +Title = Process: Pre-Tx Prime Timeout +Message = Dialyzer prime timeout.\n- Check blood and dialysate lines for clamps, kinks or leaks. [238] -Title = Cartridge Needed -Message = Cartridge not loaded or loaded improperly.\n- Check that a cartridge is properly installed. -Cartridge Needed = Cartridge not loaded or loaded improperly.\n- Check that a cartridge is properly installed. +Title = Process: Pre-Tx Dry Self-Test +Message = Self-test has detected cartridge is not installed.\n- Check that a cartridge is properly installed. [239] -Title = Cartridge Removal Error +Title = Process: Post-Tx Remove Cartridge Message = Cartridge not unloaded, or unloaded improperly.\n- Check that the cartridge has been removed. -Cartridge Removal Error = Cartridge not unloaded, or unloaded improperly.\n- Check that the cartridge has been removed. [240] -Title = Dialysate Conductivity Error -Message = Dialysate conductivity out of range.\n- Check to be sure the correct bicarbonate dialysate concentrate is connected. -Dialysate Conductivity Error = Dialysate conductivity out of range.\n- Check to be sure the correct bicarbonate dialysate concentrate is connected. +Title = Dial. Gen: Bicarb Conc. Cond. +Message = Bicarbonate concentrate conductivity during prime is out of range.\n- Check correct acid concentrate is connected and full.\n- Resume to reprime concentrate. +SRSDG 482 = [241] -Title = Cleaning Mode Error -Message = Call service to schedule a repair. -Cleaning Mode Error = Call service to schedule a repair. +Title = Cleaning: Resv Drain Timeout +Message = Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists call service to schedule a repair. +SRSDG 848 +SRSDG 90 +SRSDG 561 +SRSDG 577 +SRSDG 590 +SRSDG 591 +SRSDG 336 +SRSDG 879 +SRSDG 340 +SRSDG 496 +SRSDG 501 +SRSDG 505 +SRSDG 532 +SRSDG 535 +SRSDG 556 +SRSDG 557 +SRSDG 1048 +SRSDG 1049 +SRSDG 651 +SRSDG 655 +SRSDG 744 +SRSDG 745 +SRSDG 1004 +SRSDG 1008 +SRSDG 1019 +SRSDG 1023 +SRSDG 1033 +SRSDG 1034 = [242] -Title = Cleaning Mode Error -Message = Call service to schedule a repair. -Cleaning Mode Error = Call service to schedule a repair. +Title = Cleaning: Resv Fill Timeout +Message = Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists call service to schedule a repair. +SRSDG 850 +SRSDG 573 +SRSDG 574 +SRSDG 579 +SRSDG 580 +SRSDG 492 +SRSDG 493 +SRSDG 498 +SRSDG 499 +SRSDG 508 +SRSDG 509 +SRSDG 519 +SRSDG 690 +SRSDG 691 +SRSDG 703 +SRSDG 711 +SRSDG 1020 +SRSDG 1024 = [243] -Title = Heat Disinfection Error -Message = Call service to schedule a repair. -Heat Disinfection Error = Call service to schedule a repair. +Title = Cleaning: Fluid Loss Detected +Message = Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists call service to schedule a repair. +SRSDG 853 = [244] -Title = Cleaning Mode Error -Message = Call service to schedule a repair. -Cleaning Mode Error = Call service to schedule a repair. +Title = Cleaning: Temp Sensor Check +Message = Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists call service to schedule a repair. +SRSDG 852 = [245] -Title = Heat Disinfection Error -Message = Call service to schedule a repair. -Heat Disinfection Error = Call service to schedule a repair. +Title = Cleaning: Heat Disinfect Temp TO +Message = Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists call service to schedule a repair. +SRSDG 854 = [246] -Title = Chemical Disinfection Error -Message = Call service to schedule a repair. -Chemical Disinfection Error = Call service to schedule a repair. +Title = Cleaning: RO Water Cond Error +Message = Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists call service to schedule a repair. [247] -Title = Heat Disinfection Active Cool Error -Message = Call service to schedule a repair. -Heat Disinfection Active Cool Error = Call service to schedule a repair. +Title = +Message = [248] -Title = Chemical Disinfection Error -Message = Call service to schedule a repair. -Chemical Disinfection Error = Call service to schedule a repair. +Title = Cleaning: Chem Disinfect Proc +Message = Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists call service to schedule a repair. [249] -Title = Chemical Disinfection Error -Message = Call service to schedule a repair. -Chemical Disinfection Error = Call service to schedule a repair. +Title = Cleaning: Chem Disinf PAA Cond +Message = Unable to sense proper chemical disinfectant.\n- Cleaning mode process has terminated.\n- Check that proper chemical disinfectant is connected to the bicarb port.\n- Check chemical disinfectant bottle is not empty. +SRSDG 992 = [250] -Title = Chemical Disinfect -Message = Insert the Acid Bottle -Chemical Disinfect = Insert the Acid Bottle +Title = Cleaning: Chem Disinf Connect PAA +Message = Connect chemical disinfectant bottle to bicarb port. +SRSDG 1046 = [251] -Title = Machine Error +Title = HD POST: Sys Rec NVRAM CRC Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. [252] -Title = Machine Error +Title = HD POST: Serv Rec NVRAM CRC Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. [253] -Title = Machine Error +Title = DG POST: Sys Rec NVRAM CRC Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. +SRSDG 609 = [254] -Title = Machine Error +Title = DG POST: Serv Rec NVRAM CRC Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. +SRSDG 610 = [255] -Title = Machine Error +Title = HD POST: UI Compatibility Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. [256] -Title = Self-Test Error -Message = Call service to schedule a repair. -Self-Test Error = Call service to schedule a repair. +Title = Cleaning: Chem Flush In Progress +Message = Chemical disinfect flush in progress\n- Please wait for the process to complete\n- Treatment will not be able to be started untill process completes\n- Process may be terminated by pressing the HD stop button + = SRSUI 497 [257] -Title = Machine Error -Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. +Title = +Message = [258] -Title = Machine Error -Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. +Title = +Message = [259] -Title = Temperature Sensors Error +Title = HD Fault: Temp Sensors Error Message = Call service to schedule a repair. -Temperature Sensors Error = Call service to schedule a repair. [260] -Title = Machine Error +Title = HD POST: UI Image Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. + = SRSUI 1067 [261] -Title = Machine Error +Title = HD POST: UI CAN Driver Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. + = SRSUI 1068 [262] -Title = Machine Error +Title = HD POST: UI Disp Driver Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. + = SRSUI 1069 [263] -Title = Machine Error +Title = HD POST: UI Touch Driver Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. + = SRSUI 1070 [264] -Title = Machine Error -Message = SD-Card Failure \n- Power cycle the system.\n- Call service to schedule a repair if problem persist. -Machine Error = SD-Card Failure \n- Power cycle the system.\n- Call service to schedule a repair if problem persist. +Title = HD POST: UI SD-Card +Message = SD-Card Failure \n- Power cycle the system.\n- Call service to schedule a repair if problem persists + = SRSUI 1071 [265] -Title = Machine Error +Title = HD POST: UI RTC Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. + = SRSUI 1072 [266] -Title = Machine Error +Title = HD POST: UI WiFi Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. + = SRSUI 1073 [267] -Title = Machine Error +Title = HD POST: UI Bluetooth Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. + = SRSUI 1074 [268] -Title = Machine Error +Title = HD POST: UI Ethernet Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. + = SRSUI 1075 [269] -Title = Machine Error +Title = HD POST: UI Sound Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. + = SRSUI 1076 [270] -Title = Self Test Error +Title = HD POST: Proc Safestate Message = Call service to schedule a repair. -Self Test Error = Call service to schedule a repair. [271] -Title = Self Test Error +Title = DG POST: Proc Safestate Message = Call service to schedule a repair. -Self Test Error = Call service to schedule a repair. +SRSDG 822 = [272] -Title = Fans Error +Title = HD Alarm (Low): Fan Speed Message = Fan failure.\n- Check that the fans inlets are not blocked or obstructed. -Fans Error = Fan failure.\n- Check that the fans inlets are not blocked or obstructed. [273] -Title = Blood Pump Error -Message = Call service to schedule a repair. -Blood Pump Error = Call service to schedule a repair. +Title = +Message = [274] -Title = Dialysate Pump Error -Message = Call service to schedule a repair. -Dialysate Pump Error = Call service to schedule a repair. +Title = +Message = [275] -Title = Arterial Pressure Error +Title = HD Fault: Arterial Press Range Message = Call service to schedule a repair. -Arterial Pressure Error = Call service to schedule a repair. [276] -Title = Venous Pressure Error +Title = HD Fault: Venous Press Range Message = Call service to schedule a repair. -Venous Pressure Error = Call service to schedule a repair. [277] -Title = Occlusion Sensor Error +Title = HD Fault: Occlusion Sens Range Message = Call service to schedule a repair. -Occlusion Sensor Error = Call service to schedule a repair. [278] -Title = Dialysate Production Error -Message = Ultrafiltration error. -Dialysate Production Error = Ultrafiltration error. +Title = DG Fault: Reservoir Overfill +Message = Call service to schedule a repair. [279] -Title = Dialysate Drain Pump Error +Title = DG Fault: Reservoir Drain Message = Call service to schedule a repair. -Dialysate Drain Pump Error = Call service to schedule a repair. +SRSDG 752 = [280] -Title = Drain Pump Error +Title = DG Fault: DRP Direction Fault Message = Call service to schedule a repair. -Drain Pump Error = Call service to schedule a repair. +SRSDG 888 = [281] -Title = Acid Concentrate Volume Low +Title = Dial. Gen: Acid Conc. Low Message = Acid concentrate low.\n- Replace acid concentrate bottle. -Acid Concentrate Volume Low = Acid concentrate low.\n- Replace acid concentrate bottle. +SRSDG 836 = [282] -Title = Bicarbonate Concentrate Volume Low +Title = Dial. Gen: Bicarb Conc. Low Message = Bicarbonate concentrate low.\n- Replace bicarbonate concentrate bottle. -Bicarbonate Concentrate Volume Low = Bicarbonate concentrate low.\n- Replace bicarbonate concentrate bottle. +SRSDG 837 = [283] -Title = Load Cells Error +Title = DG Fault: LC Range Message = Call service to schedule a repair. -Load Cells Error = Call service to schedule a repair. +SRSDG 615 = [284] -Title = Load Cells Error +Title = DG Fault: Redundant LC Check Message = Call service to schedule a repair. -Load Cells Error = Call service to schedule a repair. +SRSDG 383 = [285] -Title = Dialysate Recirculation Error -Message = Dialysate recirculation error. -Dialysate Recirculation Error = Dialysate recirculation error. +Title = +Message = [286] -Title = Rinseback Complete -Message = Rinseback complete. -Rinseback Complete = Rinseback complete. +Title = Cleaning: Conc Cap Removed +Message = Concentrate cap removed from DG during cleaning.\n- Cleaning Process Terminated. [287] -Title = Machine Error +Title = HD Fault: Proc-FPGA Clock Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. [288] -Title = Load Cells Error +Title = DG Fault: LC Drift Check Message = Call service to schedule a repair. -Load Cells Error = Call service to schedule a repair. [289] -Title = Cleaning Mode Error -Message = Check dialysate/concentrate caps. -Cleaning Mode Error = Check dialysate/concentrate caps. +Title = Cleaning: Dialysate Cap Removed +Message = Dialysate cap removed from DG during cleaning.\n- Cleaning Process Terminated. +SRSDG 928 = [290] -Title = FPGA Error +Title = HD Fault: Ven. Pres. Com Message = Call service to schedule a repair. -FPGA Error = Call service to schedule a repair. [291] -Title = Cleaning Modes Start Alarm -Message = No Instructions -Cleaning Modes Start Alarm = No Instructions +Title = Cleaning: Flush In Progress +Message = System flush in progress\n- Please wait for the process to complete\n- Treatment will not be able to be started untill process completes\n- Process may be terminated by pressing the HD stop button [292] -Title = Cleaning Modes Start Alarm -Message = No Instructions -Cleaning Modes Start Alarm = No Instructions +Title = Cleaning: Heat Disinf In Progress +Message = Heat disinfect in progress\n- Please wait for the process to complete\n- Treatment will not be able to be started untill process completes\n- Process may be terminated by pressing the HD stop button [293] -Title = Cleaning Modes Start Alarm -Message = No Instructions -Cleaning Modes Start Alarm = No Instructions +Title = Cleaning: Chem Flush In Progress +Message = Chemical disinfect flush in progress\n- Please wait for the process to complete\n- Treatment will not be able to be started untill process completes\n- Process may be terminated by pressing the HD stop button [294] -Title = Cleaning Modes Start Alarm -Message = No Instructions -Cleaning Modes Start Alarm = No Instructions +Title = +Message = [295] -Title = Machine Error +Title = HD POST: UI CloudSync Message = Call service to schedule a repair. -Machine Error = Call service to schedule a repair. + = SRSUI 1238 [296] -Title = FPGA Error +Title = DG Fault: TDi RTD Comm Message = Call service to schedule a repair. -FPGA Error = Call service to schedule a repair. +SRSDG 951 = [297] -Title = FPGA Error +Title = DG Fault: TRo RTD Comm Message = Call service to schedule a repair. -FPGA Error = Call service to schedule a repair. +SRSDG 950 = [298] -Title = FPGA Error +Title = DG Fault: Baro Pres Comm Message = Call service to schedule a repair. -FPGA Error = Call service to schedule a repair. +SRSDG 948 = [299] -Title = Self Test Error +Title = DG POST: Serial Number Check Message = Call service to schedule a repair. -Self Test Error = Call service to schedule a repair. +SRSDG 952 = [300] -Title = Self Test Error +Title = HD POST: Serial Number Check Message = Call service to schedule a repair. -Self Test Error = Call service to schedule a repair. [301] -Title = Heaters Error -Message = Call service to schedule a repair. -Heaters Error = Call service to schedule a repair. +Title = +Message = [302] -Title = Processor RAM error +Title = DG Fault: Processor RAM error Message = Call service to schedule a repair. -Processor RAM error = Call service to schedule a repair. +SRSDG 126 = [303] -Title = FPGA Error +Title = DG Fault: DRP Hall Commutation Message = Call service to schedule a repair. -FPGA Error = Call service to schedule a repair. +SRSDG 958 = [304] -Title = Self-Test Error +Title = HD POST: Usage Rec NVRAM CRC Message = Call service to schedule a repair. -Self-Test Error = Call service to schedule a repair. [305] -Title = Processor RAM error +Title = HD Fault: Processor RAM error Message = Call service to schedule a repair. -Processor RAM error = Call service to schedule a repair. [306] -Title = Air Trap Error -Message = Air Trap Error.\n- Check air trap fill level. -Air Trap Error = Air Trap Error.\n- Check air trap fill level. +Title = DG Fault: CD1 CD2 Check +Message = Call service to schedule a repair. [307] -Title = HD AC power loss -Message = HD power has been lost. Check all electrical connections.\n- The display and CPU will run off of the battery until power returns. -HD AC power loss = HD power has been lost. Check all electrical connections.\n- The display and CPU will run off of the battery until power returns. +Title = Blood Stop: Loss of AC Power +Message = HD power has been lost. \n- Treatment must be terminated.\n-Check all electrical connections.\n- The display and CPU will run off of the battery until power returns.\n-If power is returned prior to blood stopped countdown elapses rinseback will be allowed. [308] -Title = Conductivity Sensors Error +Title = DG Fault: CPi Comm Message = Call service to schedule a repair. -Conductivity Sensors Error = Call service to schedule a repair. +SRSDG 959 = [309] -Title = Conductivity Sensors Error +Title = DG Fault: CPo Comm Message = Call service to schedule a repair. -Conductivity Sensors Error = Call service to schedule a repair. +SRSDG 960 = [310] -Title = Conductivity Sensors Error +Title = DG Fault: CD1 Comm Message = Call service to schedule a repair. -Conductivity Sensors Error = Call service to schedule a repair. +SRSDG 962 = [311] -Title = Conductivity Sensors Error +Title = DG Fault: CD2 Comm Message = Call service to schedule a repair. -Conductivity Sensors Error = Call service to schedule a repair. +SRSDG 961 = [312] -Title = Dialysate Flowrate Error -Message = Call service to schedule a repair. -Dialysate Flowrate Error = Call service to schedule a repair. +Title = Dial. Gen: Dialysate In Flow +Message = Dialysate in flow rate is low\n- Check dialysate line connection to the DG. [313] -Title = Cleaning Mode Inlet Water Temperature Too Low -Message = Inlet water temperature too low.\n- Check the incoming water for issues. -Cleaning Mode Inlet Water Temperature Too Low = Inlet water temperature too low.\n- Check the incoming water for issues. +Title = Cleaning: Inlet Water Temp Low +Message = Cleaning Mode Inlet water temperature too low.\n- Cleaning mode process has terminated \n- Check inlet water before restarting cleaning mode. +SRSDG 1064 +SRSDG 1052 +SRSDG 968 = [314] -Title = Cleaning Mode Inlet Water Pressure Too High -Message = Inlet water pressure too high.\n- Check the incoming water for issues. -Cleaning Mode Inlet Water Pressure Too High = Inlet water pressure too high.\n- Check the incoming water for issues. +Title = Cleaning: Inlet Water Press High +Message = Cleaning Mode Inlet water pressure too high.\n- Cleaning mode process has terminated \n- Check inlet water before restarting cleaning mode. +SRSDG 1063 +SRSDG 1051 +SRSDG 967 = [315] -Title = Cleaning Mode Inlet Water Pressure Too Low -Message = Inlet water pressure too low.\n- Check the incoming water for issues. -Cleaning Mode Inlet Water Pressure Too Low = Inlet water pressure too low.\n- Check the incoming water for issues. +Title = Cleaning: Inlet Water Press Low +Message = Cleaning Mode Inlet water pressure too low.\n- Cleaning mode process has terminated \n- Check inlet water before restarting cleaning mode. +SRSDG 1068 +SRSDG 1056 +SRSDG 966 = [316] -Title = Acid Concentrate Pump Park Fault +Title = DG Fault: Acid CP Pump Park Message = Call service to schedule a repair. -Acid Concentrate Pump Park Fault = Call service to schedule a repair. +SRSDG 983 = [317] -Title = Bicarb Concentrate Pump Park Fault +Title = DG Fault: Bicarb CP Pump Park Message = Call service to schedule a repair. -Bicarb Concentrate Pump Park Fault = Call service to schedule a repair. +SRSDG 984 = [318] -Title = Air Pump Operation Timeout -Message = Call service to schedule a repair. -Air Pump Operation Timeout = Call service to schedule a repair. +Title = HD Fault: Air Pump Timeout +Message = Unable to reduce fluid level.\n- Air trap may be overfilled.\n- Pressure transducer protector may be contaminated.\n- Treatment must be terminated without option for rinseback.\n- Call service to schedule a repair. [319] -Title = Chemical Disinfect Flush -Message = Collect Flush Sample. -Chemical Disinfect Flush = Collect Flush Sample. +Title = Cleaning: Chem Residual Sampling +Message = Collect chemical residuals water sample from drain line. +SRSDG 1040 = [320] -Title = Chemical Disinfect Flush +Title = Cleaning: Chem Residual Timeout +Message = During Chemical Disinfection Flush\n-user residual sampling timed out. +SRSDG 1043 = + +[321] +Title = DG Fault: UVo Error Message = Call service to schedule a repair. -Chemical Disinfect Flush = Call service to schedule a repair. +SRSDG 1069 = +[322] +Title = HD POST Alarm: UI Invalid Year +Message = Call service to schedule a repair. +