Index: Alarms/Alarms.conf =================================================================== diff -u -r8ab92164ee0b38ae17850876d69afa9794c4bef4 -r756f204e85eb81282d4cda10c0e33d8b5d567faf --- Alarms/Alarms.conf (.../Alarms.conf) (revision 8ab92164ee0b38ae17850876d69afa9794c4bef4) +++ Alarms/Alarms.conf (.../Alarms.conf) (revision 756f204e85eb81282d4cda10c0e33d8b5d567faf) @@ -361,7 +361,7 @@ [68] Title = Dialysate Generation Error ListTitle = Dial. Gen: Dialysate not ready -Message = A problem has been detected with dialysate generation. \n- Treatment is paused and will be need to be resumed when \ndialysate is ready for use. +Message = A problem has been detected with dialysate generation. \n- Treatment is paused and will need to be resumed when \ndialysate is ready for use. [69] Title = Service Required: Hemodialysis Device @@ -684,7 +684,7 @@ [127] Title = Low Venous Pressure ListTitle = Blood Stop: Venous Pres. Low -Message = Venous pressure is low.\n- Ensure venous access connections are properly secured.\n- Check needle placement and resolve access\n issues, if applicable.\n- Check to ensure transducers are securely connected.\n- Inspect transducer for moisture and change if applicable.\n- Inspect dialyzer for clots. If clots are present, follow\n facility policy to end treatment.\n- Press Resume/OK to continue treatment. +Message = Venous pressure is low.\n- Ensure venous access connections are properly secured.\n- Check needle placement and resolve access issues, \nif applicable.\n- Check air trap for foam and that transducers are secured.\n- Inspect transducer for moisture and change, if applicable.\n- Inspect dialyzer for clots. If clots are present, follow\n facility policy to end treatment.\n- Press Resume/OK to continue treatment. [128] Title = Venous Air Detected @@ -699,7 +699,7 @@ [130] Title = High Venous Pressure ListTitle = Blood Stop: Venous Pres. High -Message = Venous pressure is high. \n- Check venous bloodlines for kinks or clamps.\n- Check needle placement and/or access position.\n- Resolve access issues, if applicable.\n- Check to ensure transducers are securely connected.\n- Inspect transducer for moisture and change if applicable.\n- If clots are present, end treatment without rinseback. +Message = Venous pressure is high. \n- Check venous bloodlines for kinks or clamps.\n- Check needle placement and/or access position.\n- Resolve access issues, if applicable.\n- Check air trap for foam and that transducers are secured.\n- Inspect transducer for moisture and change, if applicable.\n- If clots are present, end treatment without rinseback.\n- Press Resume/OK to continue treatment. [131] Title = Low Arterial Pressure @@ -1562,7 +1562,7 @@ [278] Title = Dialysate Reservoir Error ListTitle = Dial. Gen: Reservoir Overfill -Message = A problem has been detected with dialysate generation. \n- Treatment is paused and will be need to be resumed\n when dialysate is ready for use. +Message = A problem has been detected with dialysate generation. \n- Treatment is paused and will need to be resumed when \ndialysate is ready for use. [279] Title = Service Required: Dialysate Device