Index: Alarms/Alarms.conf =================================================================== diff -u -r4a663fb4458205153d56bd69bf9ab99ca8f0f911 -r7d541ef8d64676e27620c5f6da49076c018315cb --- Alarms/Alarms.conf (.../Alarms.conf) (revision 4a663fb4458205153d56bd69bf9ab99ca8f0f911) +++ Alarms/Alarms.conf (.../Alarms.conf) (revision 7d541ef8d64676e27620c5f6da49076c018315cb) @@ -360,7 +360,7 @@ [84] Title = Service Required: Dialysate Device -Message = A problem was detected with the dialysate device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair.\n\nDG POST: HD RTC Time +Message = A problem was detected with the dialysate device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair.\n\nDG POST: DG RTC Time SRSDG 815 = [85] @@ -432,8 +432,8 @@ Message = A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair.\n\nHD Fault: Syringe Pump Stall [100] -Title = Service Required: Hemodialysis Device -Message = A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair.\n\nHD Fault: Timeout No Cart ST +Title = +Message = \n\n [101] Title = Service Required: Hemodialysis Device @@ -645,7 +645,7 @@ [147] Title = Dialysate Generation Error -Message = A problem has been detected with dialysate generation. \n- Treatment is paused and will be need to be resumed when \nthe dialysate is ready for use. \n\nDial. Gen: Dialysate not ready +Message = A problem has been detected with dialysate generation. \n- Treatment is paused and will need to be resumed when \nthe dialysate is ready for use. \n\nDial. Gen: Dialysate not ready SRSDG 398 = [148] @@ -1002,7 +1002,7 @@ [225] Title = Treatment Complete -Message = Dialysis treatment is complete.\n- Press OK to end treatment and rinseback.\n\nProcess: End of Treatment +Message = Dialysis treatment is complete.\n- If blood sampling is required, draw blood at\n the arterial sample port\n- Press RINSEBACK to end treatment and rinseback.\n\nProcess: End of Treatment [226] Title = Priming Complete @@ -1053,11 +1053,11 @@ Message = A problem has been detected during self- test. \n- Cartridges are single- use only and fluid is present.\n- Install new cartridge to resume.\n\nProcess: Pre- Tx Dry Self- Test [237] -Title = Priming Error -Message = A problem has been detected during prime. \n- Prime was unable to complete. \n - Check blood and dialysate lines for clamps, kinks or leaks. \n\nProcess: Pre- Tx Prime Timeout +Title = +Message = \n\n [238] -Title = Cartridge Not Dectected +Title = Cartridge Not Detected Message = A problem has been detected during self- test. \n- Cartridge is not detected.\n- Confirm cartridge is properly installed.\n\nProcess: Pre- Tx Dry Self- Test [239] @@ -1212,7 +1212,6 @@ [262] Title = Message = \n\n - = SRSUI 1069 [263] Title = Service Required: Hemodialysis Device