Index: Instructions/Instructions.conf =================================================================== diff -u -rf1e2eee61d89a557d4058dd9b7a9ca0cfd846ec0 -r88c772bbd03e098de75d4b296b14027c902c96aa --- Instructions/Instructions.conf (.../Instructions.conf) (revision f1e2eee61d89a557d4058dd9b7a9ca0cfd846ec0) +++ Instructions/Instructions.conf (.../Instructions.conf) (revision 88c772bbd03e098de75d4b296b14027c902c96aa) @@ -8,7 +8,7 @@ Water sample result failed. = 44_water test fail B-01.png [Consumables^Consumables Installation] -Remove the concentrate and dialysate caps. = 48_remove caps alternative-01.png +Remove the concentrate and dialysis fluid caps. = 48_remove caps alternative-01.png Connect the acid concentrate to the acid port. = 13_install acid line_v4.png Connect the bicarbonate concentrate to the bicarbonate port. = 14_install bicarb line_v4.png @@ -21,23 +21,23 @@ [Disposables^Cartridge Connection] Connect the cartridge blood lines to the dialyzer. = 25_filter connection 1A+1B-01.png -Connect the cartridge dialysis fluid lines to the dialyzer. = 26_fiilter connection 2A + 2B-01.png +Connect the cartridge dialysis fluid lines to the dialyzer. = 26_fiilter connection 2A + 2B-01.png Insert dialyzer into the clamps. = 24_load filter-01.png Connect the arterial pressure line to the arterial pressure transducer port. = 27_PBo connection Arterial-01.png Connect the venous pressure line to the venous pressure transducer port. = 28_PBo connection venous-01.png Connect the cartridge dialysis fluid lines to the DG fluid ports. = 20_dialysate lines to DG_v4.png [Disposables^Heparin Syringe] Fill a syringe with heparin and connect the cartridge heparin tubing line. = 30_fill syringe with heparin_v4.png -Insert heparin filled syringe into the infusion pump housing. = 31_load syringe-01.png +Insert heparin filled syringe into the syringe pump. = 31_load syringe-01.png [Disposables^Saline Bag] Hang the saline bag on the left side hook. Spike a saline bag and connect it to the cartridge saline line. = 34_saline connect-01.png Pinch saline y-connector to the closed position. = 35_clamping Y connecter-01.png Close the front panel door. = 2_HD door closed-01.png [Connection^Patient Connection] -Draw a dialysate sample from the needless valve port. = 21_take sample with syringe_v4.png +Draw a dialysis fluid sample from the needless valve port. = 21_take sample with syringe_v4.png Wash your hands and establish vascular access per your clinic's instructions. = 45_wash hands-01.png Pinch arterial clamp and venous clamp on located on the cartridge patient lines. = 23_pinch Arteriaal and Venous tubes-01.png Remove arterial and venous line connector. = 39_remove shunt_v4.png @@ -57,13 +57,13 @@ Pinch arterial and venous line after rinseback is complete. = 41_clamp Arterial saline Line-01.png [Disconnection^Patient Disconnection] -Pinch arterial clamp and venous clamp on located on the cartridge patient lines and access lines. = 37_unpinch Arterial Venous to patient-01.png +Pinch arterial clamp and venous clamp located on the cartridge patient lines and access lines. = 37_unpinch Arterial Venous to patient-01.png Disconnect arterial and venous cartridge lines from your patient access lines. = 38_disconnect Arterial patient access-01.png [Disposables^Disposables Removal] Disconnect the arterial and venous pressure lines. = 29_PBo connection remove-01.png -Remove heparin syringe from the infusion pump housing. = 33_remove syringe-01.png -Pinch dialysate lines and disconnect tubing lines from the system. = 22_disconnect dialysate from cassette_v4.png +Remove heparin syringe from the syringe housing. = 33_remove syringe-01.png +Pinch dialysis fluid lines and disconnect tubing lines from the system. = 22_disconnect dialysate from cassette_v4.png Install dialysis fluid cap. = 15_replace dialysate line cap_v4.png Disconnect acid and bicarbonate concentrates tubing lines from the system.= 16_remove acid and bicarb connect_v4.png Install concentrate fluid cap. = 19_replace concentrate cap-01.png @@ -85,3 +85,4 @@ Remove the concentrate fluid cap and connect the chemical disinfectant = 17_connect PAA_v4.png Disconnect the chemical disinfectant and replace concentrate cap. = 19_replace concentrate cap-01.png Test the system for residual chemicals using a test strip. = 43_test residual sample-01.png +