Index: Alarms/Alarms.conf =================================================================== diff -u -r3cfb50d5dd4cb017bbbc2bfb2224c125c2f47b6e -rdc47c152ccbe97b1c8edd010d84a98c6163e9e77 --- Alarms/Alarms.conf (.../Alarms.conf) (revision 3cfb50d5dd4cb017bbbc2bfb2224c125c2f47b6e) +++ Alarms/Alarms.conf (.../Alarms.conf) (revision dc47c152ccbe97b1c8edd010d84a98c6163e9e77) @@ -684,7 +684,7 @@ [127] Title = Low Venous Pressure ListTitle = Blood Stop: Venous Pres. Low -Message = Venous pressure is low.\n- Ensure venous access connections are properly secured.\n- If there has been an access disconnection or needle\n dislodgement, follow facility policy to address and\nterminate treatment without rinseback.\n- If access connections are properly secured, \npress Resume/OK to continue treatment. +Message = Venous pressure is low.\n- Ensure venous access connections are properly secured.\n- Check needle placement and resolve access\n issues, if applicable.\n- Check to ensure transducers are securely connected.\n- Inspect transducer for moisture and change if applicable.\n- Inspect dialyzer for clots. If clots are present, follow\n facility policy to end treatment.\n- Press Resume/OK to continue treatment. [128] Title = Venous Air Detected @@ -699,17 +699,17 @@ [130] Title = High Venous Pressure ListTitle = Blood Stop: Venous Pres. High -Message = Venous pressure is high. \n- Check venous bloodlines for kinks or clamps.\n- Check needle placement and/or access position.\n- Resolve access issues, if applicable.\n- If clots are present, end treatment without rinseback. +Message = Venous pressure is high. \n- Check venous bloodlines for kinks or clamps.\n- Check needle placement and/or access position.\n- Resolve access issues, if applicable.\n- Check to ensure transducers are securely connected.\n- Inspect transducer for moisture and change if applicable.\n- If clots are present, end treatment without rinseback. [131] Title = Low Arterial Pressure ListTitle = Blood Stop: Arterial Pres. Low -Message = Arterial pressure is low.\n- Inspect arterial bloodlines for kinks or clamps.\n- Check needle placement or access position.\n- Resolve access issues, if applicable.\n- If clots are present, end treatment without rinseback. +Message = Arterial pressure is low.\n- Inspect arterial bloodlines for kinks or clamps.\n- Check needle placement or access position.\n- Resolve access issues, if applicable.\n- Check to ensure transducers are securely connected.\n- Inspect transducer for moisture and change if applicable.\n- If clots are present, end treatment without rinseback. [132] Title = High Arterial Pressure ListTitle = Blood Stop: Arterial Pres. High -Message = Arterial pressure is high.\n- Ensure arterial access connections are properly secured.\n- Check needle placement and/or access position.\n- Resolve access issues if applicable.\n- If clots are present, end treatment without rinseback. +Message = Arterial pressure is high.\n- Check venous bloodlines for kinks or clamps.\n- Check needle placement and/or access position.\n- Resolve access issues if applicable.\n- Check to ensure transducers are securely connected.\n- Inspect transducer for moisture and change if applicable.\n- If clots are present, end treatment without rinseback. [133] Title = Dialysate Device Fluid Leak @@ -1055,7 +1055,7 @@ [193] Title = Blood Pump Stopped: Partial Occlusion ListTitle = Blood Stop: Blood Pump Partial Occlusion -Message = Partial occlusion detected after the blood pump.\n- Inspect bloodlines for kinks or clamps.\n- Check needle placement or access position.\n- Resolve access issues, if applicable.\n- If clots are present, end treatment without rinseback. +Message = Partial occlusion detected after the blood pump.\n- Inspect bloodlines for kinks or clamps.\n- Check needle placement or access position.\n- Resolve access issues, if applicable.\n- Inspect dialyzer for clots. If clots are present, follow\n facility policy to end treatment. [194] Title = Service Required: Dialysate Device @@ -1560,9 +1560,9 @@ Message = A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. [278] -Title = Service Required: Dialysate Device -ListTitle = DG Fault: Reservoir Overfill -Message = A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. +Title = Dialysate Reservoir Error +ListTitle = Dial. Gen: Reservoir Overfill +Message = A problem has been detected with dialysate generation. \n- Treatment is paused and will be need to be resumed\n when dialysate is ready for use. [279] Title = Service Required: Dialysate Device