Index: Alarms/Alarms.conf =================================================================== diff -u -re3fb71ab69a5c2b0768705738b75cf3c0d1b060f -re20b995ef22c8516d2bf04ba8efb68406ad47804 --- Alarms/Alarms.conf (.../Alarms.conf) (revision e3fb71ab69a5c2b0768705738b75cf3c0d1b060f) +++ Alarms/Alarms.conf (.../Alarms.conf) (revision e20b995ef22c8516d2bf04ba8efb68406ad47804) @@ -1,1077 +1,1077 @@ [0] -Title = ` +Title = Indication for when no alarms is a possible situation Message = [1] -Title = HD POST: Stuck Button -Message = Stop or On button pressed during startup\n-Release button and power cycle\n-Call service to schedule a repair if problem persists +Title = HD stuck button POST failure. Stop or Off button detected to be pressed for at least 1 second during test shortly after power up +Message = HD [2] -Title = HD POST: FPGA Compatibility -Message = Call service to schedule a repair. +Title = HD FPGA POST failure +Message = HD [3] -Title = DG POST: FPGA Compatibility -Message = Call service to schedule a repair. +Title = DG FPGA POST failure +Message = DG SRSDG 602 SRSDG 814 SRSDG 1061 = [4] -Title = HD POST: WD Safestate -Message = Call service to schedule a repair. +Title = HD Watchdog POST failure +Message = HD [5] -Title = DG POST: WD Safestate -Message = Call service to schedule a repair. +Title = DG Watchdog POST failure +Message = DG SRSDG 53 = [6] -Title = HD POST: Proc-UI Comm -Message = Call service to schedule a repair. +Title = HD UI communication POST failure. UI failed to communicate within a reasonable time after power up +Message = HD [7] -Title = HD Alarm (Low): RTC Bat Low -Message = Call service to schedule a repair. +Title = HD RTC battery low +Message = HD [8] -Title = HD POST: Acc Vector -Message = Call service to schedule a repair. +Title = HD accelerometer failed POST +Message = HD [9] -Title = DG POST: Acc Vector -Message = Call service to schedule a repair. +Title = DG accelerometer failed POST +Message = DG SRSDG 323 = [10] -Title = HD POST: BLD Config Emb Mode -Message = Call service to schedule a repair. +Title = HD blood leak sensor setting embedded mode failure. +Message = HD [11] -Title = Dial. Gen: Dialysate Temp Low -Message = Dialysate temperature is low\n- Treatment is paused and will be ready to resume when \ndialysate is within target range. +Title = HD dialysate temperature below target temperature or below safety temp +Message = HD [12] -Title = HD POST: HD Image -Message = Call service to schedule a repair. +Title = HD firmware image integrity POST test failed +Message = HD [13] -Title = DG POST: DG Image -Message = Call service to schedule a repair. +Title = DG firmware image integrity POST test failed +Message = DG SRSDG 813 = [14] -Title = DG POST: Usage Rec NVRAM CRC -Message = Call service to schedule a repair. +Title = DG invalid usage record CRC +Message = DG SRSDG 957 = [15] -Title = Dial. Gen: Dialysate Temp High -Message = Dialysate temperature is high\n-Treatment is paused and will be ready to resume when \ndialysate is within target range. +Title = HD dialysate temperature above high safety. +Message = HD [16] -Title = HD POST: Primary Alarm Current -Message = Call service to schedule a repair. +Title = HD alarm audio failed POST +Message = HD [17] -Title = HD POST: UI POST Not Complete -Message = Call service to schedule a repair. +Title = HD UI POST failed +Message = HD [18] -Title = Loss of DG Comm (DG ACK) -Message = Communication failure with Dialysis Generator.\n-Treatment must be terminated.\n- Ensure all cords are securely connected. +Title = HD didn't get ACK on message to DG that required acknowledgment +Message = HD [19] -Title = Dial. Gen: Dialysate Temp High -Message = Dialysate temperature is high\n- Treatment is paused and will be ready to resume when \ndialysate is within target range. +Title = HD dialysate temperature above target temperature. +Message = HD [20] -Title = DG POST: Conductivity Cal -Message = Call service to schedule a repair. +Title = DG conductivity sensors invalid calibration record +Message = DG SRSDG 16 = [21] -Title = DG POST: Drain Line Vol Cal -Message = Call service to schedule a repair. +Title = DG drain line volume invalid calibration record +Message = DG SRSDG 936 = [22] -Title = DG POST: Reservoir Vol Cal -Message = Call service to schedule a repair. +Title = DG reservoirs invalid calibration record +Message = DG SRSDG 935 = [23] -Title = DG POST: Acid Conc Cal -Message = Call service to schedule a repair. +Title = DG acid concentrate calibration record +Message = DG SRSDG 934 = [24] -Title = DG POST: Bicarb Conc Cal -Message = Call service to schedule a repair. +Title = DG bicarb concentrate calibration record +Message = DG SRSDG 933 = [25] -Title = DG POST: Acc Cal -Message = Call service to schedule a repair. +Title = DG accelerometer invalid calibration record +Message = DG SRSDG 817 = [26] -Title = HD POST: Acc Cal -Message = Call service to schedule a repair. +Title = HD accelerometer invalid calibration record +Message = HD [27] -Title = Process: Pre-Tx Wet Self-Test -Message = Self-test detected has a problem with the blood leak sensor\n- Check cartridge installation on to machine\n- If problem persists, terminate pre-treatment and restart \nwith a new cartridge. +Title = HD blood leak sensor zero and self test sequence failed +Message = HD [28] -Title = DG Fault: Conductivity RTD Comm -Message = Call service to schedule a repair. +Title = DG two wire sensors FPGA fault +Message = DG SRSDG 864 = [29] -Title = HD POST: SP DAC Cal -Message = Call service to schedule a repair. +Title = HD heparin force sensor invalid calibration record +Message = HD [30] -Title = HD Fault: SW Invalid State -Message = Call service to schedule a repair. +Title = HD Software fault. Software found itself in an unexpected state +Message = HD [31] -Title = HD Fault: BP Current -Message = Call service to schedule a repair. +Title = HD blood pump failed motor controller current check. Too high when pump should be off or out of range when pump should be running +Message = HD [32] -Title = HD Fault: BP Speed -Message = Call service to schedule a repair. +Title = HD blood pump failed motor off check. Measured speed while commanded off +Message = HD [33] -Title = HD Fault: BP Direction -Message = Call service to schedule a repair. +Title = HD blood pump failed motor direction check. Measured vs. commanded +Message = HD [34] -Title = HD Fault: BP Rotor -Message = Blood pump rotor failure.\n- Check the pump rotor for secure connection. +Title = HD blood pump failed rotor speed check. Mismatch with rotor and motor speeds +Message = HD [35] -Title = HD Fault: DPi Current -Message = Call service to schedule a repair. +Title = HD dialysis inlet pump failed motor controller current check. Too high when pump should be off or out of range when pump should be running +Message = HD [36] -Title = HD Fault: DPi Speed -Message = Call service to schedule a repair. +Title = HD dialysis inlet pump failed motor off check. Measured speed while commanded off +Message = HD [37] -Title = HD Fault: DPi Direction -Message = Call service to schedule a repair. +Title = HD dialysis inlet pump failed motor direction check. Measured vs. commanded +Message = HD [38] -Title = HD Fault: DPi Rotor -Message = Dialysate in pump rotor failure.\n- Check the pump rotor for secure connection. +Title = HD dialysis inlet pump failed rotor speed check. Mismatch with rotor and motor speeds +Message = HD [39] -Title = HD Fault: DPo Current -Message = Call service to schedule a repair. +Title = HD dialysis outlet pump failed motor controller current check. Too high when pump should be off or out of range when pump should be running +Message = HD [40] -Title = HD Fault: DPo Speed -Message = Call service to schedule a repair. +Title = HD dialysis outlet pump failed motor off check. Measured speed while commanded off +Message = HD [41] -Title = HD Fault: DPo Direction -Message = Call service to schedule a repair. +Title = HD dialysis outlet pump failed motor direction check. Measured vs. commanded +Message = HD [42] -Title = HD Fault: DPo Rotor -Message = Dialysate out pump rotor failure.\n- Check the pump rotor for secure connection. +Title = HD dialysis outlet pump failed rotor speed check. Mismatch with rotor and motor speeds +Message = HD [43] -Title = DG Fault: Iso ADC Comm -Message = Call service to schedule a repair. +Title = DG main primary heater FPGA fault +Message = DG SRSDG 954 = [44] -Title = HD Fault: UI Comm -Message = Call service to schedule a repair. +Title = HD UI communication timeout +Message = HD [45] -Title = HD Fault: CAN CRC Com -Message = Call service to schedule a repair. +Title = HD too many bad communications CRC +Message = HD [46] -Title = HD Fault: CAN ACK UI Com -Message = Call service to schedule a repair. +Title = HD didn't get ACK on message to UI that required acknowledgment +Message = HD [47] -Title = +Title = Available for use Message = [48] -Title = HD Fault: UF Rate Tare Err -Message = Call service to schedule a repair. +Title = HD ultrafiltration volume accuracy error during treatment +Message = HD [49] -Title = HD Fault: FPGA Com -Message = Call service to schedule a repair. +Title = HD FPGA communication down for too long +Message = HD [50] -Title = DG Fault: Valve Control -Message = Call service to schedule a repair. +Title = DG FPGA not accepting commanded valve states +Message = DG SRSDG 26 = [51] -Title = HD Fault: BP Speed -Message = Call service to schedule a repair. +Title = HD blood pump failed motor speed check. Measured vs. commanded +Message = HD [52] -Title = HD Fault: DPi Speed -Message = Call service to schedule a repair. +Title = HD dialysate inlet pump failed motor speed check. Measured vs. commanded +Message = HD [53] -Title = HD Fault: DPo Speed -Message = Call service to schedule a repair. +Title = HD dialysate outlet pump failed motor speed check. Measured vs. commanded +Message = HD [54] -Title = HD Fault: Critical Data Err -Message = Call service to schedule a repair. +Title = HD critical data integrity check failed +Message = HD [55] -Title = DG Fault: Critical Data Err -Message = Call service to schedule a repair. +Title = DG critical data integrity check failed +Message = DG SRSDG 921 = [56] -Title = HD Fault: Acc Com -Message = Call service to schedule a repair. +Title = HD accelerometer error (no readings or FPGA reports error) +Message = HD [57] -Title = DG Fault: Acc Com -Message = Call service to schedule a repair. +Title = DG accelerometer error (no readings or FPGA reports error) +Message = DG SRSDG 869 SRSDG 870 = [58] -Title = HD Fault: Valve Home -Message = Call service to schedule a repair. +Title = HD valve homing failed +Message = HD [59] -Title = HD Fault: Valve Transition Err -Message = Call service to schedule a repair. +Title = HD valve transition time out +Message = HD [60] -Title = HD Fault: Valve Control -Message = Call service to schedule a repair. +Title = HD valve not functional +Message = HD [61] -Title = HD Fault: Valve Current -Message = Call service to schedule a repair. +Title = HD valve current out of range +Message = HD [62] -Title = HD Fault: Valve Position -Message = Call service to schedule a repair. +Title = HD valve position out of target +Message = HD [63] -Title = HD Fault: BLD Com -Message = Call service to schedule a repair. +Title = HD blood leak FPGA fault +Message = HD [64] -Title = DG Fault: Baro Range -Message = Call service to schedule a repair. +Title = DG barometric pressure sensor out of range +Message = DG SRSDG 874 = [65] -Title = Loss of DG Comm (Reject) -Message = Communication failure with Dialysis Generator.\n-Treatment must be terminated.\n- Ensure all cords are securely connected. +Title = HD DG requests DG command with invalid parameter fault +Message = HD [66] -Title = HD POST: BLD Config Set Point -Message = Call service to schedule a repair. +Title = HD blood leak sensor set point set failure +Message = HD [67] -Title = Process: Pre-Tx Remove Cartridge -Message = Cartridge has been detected.\n- Open door\n- Remove cartridge\n- Close door\n- Resume +Title = HD blood pump occlusion self-test failure alarm +Message = HD [68] -Title = Dial. Gen: Dialysate not ready -Message = Dialysate is not yet ready.\n- Treatment is paused and will be ready to resume when \ndialysate is ready for use. +Title = HD active reservoir recirculation out of range +Message = HD [69] -Title = HD POST: BLD Cal -Message = Call service to schedule a repair. +Title = HD blood leak sensor invalid calibration record +Message = HD [70] -Title = Process: Pre-Tx Remove Cartridge -Message = Cartridge has been detected.\n- Open door\n- Remove cartridge\n- Close door\n- Resume +Title = HD arterial pressure self-test failure alarm +Message = HD [71] -Title = Process: Pre-Tx Remove Cartridge -Message = Cartridge has been detected.\n- Open door\n- Remove cartridge\n- Close door\n- Resume +Title = HD venous pressure self-test failure alarm +Message = HD [72] -Title = Loss of DG Comm (LC) -Message = Communication failure with Dialysis Generator.\n-Treatment must be terminated.\n- Ensure all cords are securely connected. +Title = HD No load cell data message receive at least once every 2 seconds +Message = HD [73] -Title = Loss of DG Comm (TDI/TRO) -Message = Communication failure with Dialysis Generator.\n-Treatment must be terminated.\n- Ensure all cords are securely connected. +Title = HD No dialysate temperature data message receive at least once every 2 seconds +Message = HD [74] -Title = DG Fault: UVi On No Flow -Message = Call service to schedule a repair. +Title = DG inlet UV reactor is on with no flow +Message = DG SRSDG 600 = [75] -Title = HD Fault: Syringe DAC -Message = Call service to schedule a repair. +Title = HD syringe pump self-test failure alarm +Message = HD [76] -Title = HD Fault: Voltage Monitor -Message = Call service to schedule a repair. +Title = HD monitored voltage is out of range +Message = HD [77] -Title = DG Fault: Voltage Monitor -Message = Call service to schedule a repair. +Title = DG monitored voltage is out of range +Message = DG SRSDG 46 SRSDG 866 SRSDG 1088 = [78] -Title = HD Fault: Syringe Pump Enc Dir -Message = Call service to schedule a repair. +Title = HD syringe pump direction (from encoder) error +Message = HD [79] -Title = HD Fault: Syringe Pump Drv Dir -Message = Call service to schedule a repair. +Title = HD syringe pump direction (from controller) error +Message = HD [80] -Title = HD Fault: Syringe Pump Driver -Message = Call service to schedule a repair. +Title = HD syringe pump fault reported by FPGA +Message = HD [81] -Title = HD Fault: Syringe Pump OT -Message = Call service to schedule a repair. +Title = HD syringe pump over travel error +Message = HD [82] -Title = HD Fault: Syringe Pump DAC Err -Message = Call service to schedule a repair. +Title = HD syringe pump DAC write failure +Message = HD [83] -Title = HD Fault: Syringe Pump On Err -Message = Call service to schedule a repair. +Title = HD syringe pump is running while the BP is off +Message = HD [84] -Title = DG POST: HD RTC Time -Message = Call service to schedule a repair. +Title = DG set RTC year is invalid +Message = DG SRSDG 815 = [85] -Title = Blood Stop: Cartridge Lever Open -Message = Cartridge Lock Lever is not closed.\n- Open front door and push lever all the way down.\n- Close door and press RESUME button to continue. +Title = HD pump track latch opened alarm +Message = HD [86] -Title = HD POST: HD RTC Time -Message = Call service to schedule a repair. +Title = HD set RTC year is invalid +Message = HD [87] -Title = DG POST: Heat Cal -Message = Call service to schedule a repair. +Title = DG heating invalid calibration record +Message = DG SRSDG 929 = [88] -Title = DG Fault: CP1 CP2 Speed Range -Message = Call service to schedule a repair. +Title = DG concentrate pumps hall sensor out of range +Message = DG [89] -Title = DG Fault: UVo On No Flow -Message = Call service to schedule a repair. +Title = DG outlet UV reactor on with no flow +Message = DG SRSDG 599 = [90] -Title = DG Fault: LC A1/B1 Comm -Message = Call service to schedule a repair. +Title = DG load cells A1/B1 FPGA fault +Message = DG SRSDG 604 = [91] -Title = Loss of DG Comm (FMD) -Message = Communication failure with Dialysis Generator.\n-Treatment must be terminated.\n- Ensure all cords are securely connected. +Title = HD No dialysate flow data receive in the last 3 seconds +Message = HD [92] Title = Message = [93] -Title = DG Fault: RO Permeate Cond High -Message = Call service to schedule a repair. +Title = DG outlet primary conductivity out of range +Message = DG SRSDG 430 = [94] -Title = DG Fault: Pressure Sensor Range -Message = Call service to schedule a repair. +Title = DG pressure out of range +Message = DG SRSDG 629 = [95] -Title = DG Fault: WD Error -Message = Call service to schedule a repair. +Title = DG watchdog expired +Message = DG SRSDG 907 = [96] -Title = Dial. Gen: Inlet Water Temp High -Message = Inlet water temperature is high.\n- Treatment is paused\n- Check the incoming water supply. +Title = DG inlet water temperature in high range +Message = DG SRSDG 410 = [97] -Title = Dial. Gen: Dialysate Cond. -Message = Dialysate conductivity is out of range.\n- Check acid and bicarb concentrate is correct and not empty. +Title = DG fill conductivity out of range +Message = DG SRSDG 397 = [98] -Title = HD Alarm (Low): Battery Com -Message = Call service to schedule a repair. +Title = HD battery communication fault +Message = HD [99] -Title = HD Fault: Syringe Pump Stall -Message = Call service to schedule a repair. +Title = HD syringe pump stall alarm +Message = HD [100] -Title = HD Fault: Timeout No Cart ST -Message = Call service to schedule a repair. +Title = HD no cartridge self-test timeout +Message = HD [101] -Title = HD POST: UI-Proc Comm -Message = Call service to schedule a repair. +Title = UI POST HD communication failure +Message = UI [102] -Title = Cleaning: Tpo THD Temp Delta -Message = Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists, call service to schedule a repair. +Title = DG heat disinfect temperature gradient out of range +Message = DG SRSDG 856 SRSDG 930 = [103] -Title = HD POST: Cal NVRAM CRC -Message = Call service to schedule a repair. +Title = HD invalid calibration CRC +Message = HD [104] -Title = HD Fault: Air Trap Sensor -Message = Call service to schedule a repair. +Title = HD air trap level sensors reporting illegal combination of air/fluid +Message = HD [105] -Title = DG POST: Cal NVRAM CRC -Message = Call service to schedule a repair. +Title = DG invalid calibration CRC +Message = DG SRSDG 608 = [106] -Title = DG POST: Flow Sensor Cal -Message = Call service to schedule a repair. +Title = DG dialysate flow sensor invalid calibration record +Message = DG SRSDG 820 SRSDG 821 SRSDG 1087 = [107] -Title = DG Fault: DG Restarted -Message = Call service to schedule a repair. +Title = HD reports DG restarted fault +Message = HD [108] -Title = HD Fault: Syringe Pump ADC Com -Message = Call service to schedule a repair. +Title = HD syringe pump ADC FPGA fault +Message = HD [109] -Title = HD Fault: Syringe Pump Vol -Message = Call service to schedule a repair. +Title = HD syringe pump volume check error +Message = HD [110] -Title = HD Fault: Syringe Pump Speed -Message = Call service to schedule a repair. +Title = HD syringe pump speed check error +Message = HD [111] -Title = HD Fault: Syringe Pump Speed -Message = Call service to schedule a repair. +Title = HD syringe pump not stopped in off state error +Message = HD [112] -Title = DG Fault: LC A2/B2 Comm -Message = Call service to schedule a repair. +Title = DG load cells A1/B1 FPGA fault +Message = DG SRSDG 953 = [113] -Title = DG Fault: DRP Current -Message = Call service to schedule a repair. +Title = DG Drain pump current out of range +Message = DG SRSDG 890 = [114] -Title = Process: Pre-Tx Wet Self-Test -Message = Self-test has detected a problem with the air bubble sensor\n- Check cartridge installation on to machine\n- If problem persists, terminate pre-treatment and \nrestart with a new cartridge. +Title = HD venous air bubble detector self-test failure +Message = HD [115] -Title = DG Fault: Temp Sensor Range -Message = Call service to schedule a repair. +Title = DG temperature sensor out of range +Message = DG SRSDG 224 = [116] -Title = HD Alarm (Low): SD-Card Error -Message = SD-Card Failure \n- Power cycle the system.\n- Call service to schedule a repair if problem persists. +Title = HD UI SD card failure +Message = UI HD [117] -Title = Loss of HD Comm (HD ACK) -Message = Communication failure with Dialysis Generator.\n-Treatment must be terminated.\n- Ensure all cords are securely connected. +Title = DG CAN message not acked +Message = DG SRSDG 909 = [118] -Title = DG Fault: RTC Config -Message = Call service to schedule a repair. +Title = DG RTC config error +Message = DG SRSDG 43 = [119] -Title = DG Alarm (Low): RTC Bat Low -Message = Call service to schedule a repair. +Title = DG RTC battery low error +Message = DG SRSDG 908 = [120] -Title = Process: Pre-Tx Wet Self-Test -Message = Self-test has detected a bubble in the venous bubble detector\n- The cartridge should be primed\n- Check cartridge installation on to machine\n- If problem persists, terminate pre-treatment and \nrestart with a new cartridge. +Title = HD pre-treatment mode wet self-test prime check failure +Message = HD [121] -Title = DG Fault: Prim Heater Lg Control -Message = Call service to schedule a repair. +Title = DG main primary heater voltage out of range +Message = DG SRSDG 611 = [122] -Title = DG Fault: Prim Heater Sm Control -Message = Call service to schedule a repair. +Title = DG small primary heater voltage out of range +Message = DG SRSDG 612 = [123] -Title = DG Fault: Trimmer Heater Control -Message = Call service to schedule a repair. +Title = DG trimmer heater voltage out of range +Message = DG SRSDG 613 = [124] -Title = Blood Stop: Blood Clot Risk -Message = Blood pump has been off for too long.\n- Treatment must be terminated. Blood clot risk.\n- NO RINSEBACK ALLOWED. +Title = HD end of treatment alarm (high priority - user still not acting to end treatment) +Message = HD [125] -Title = Blood Stop: Blood Clot Risk -Message = Blood pump has been off for too long.\n- Treatment must be terminated. Blood clot risk.\n- NO RINSEBACK ALLOWED. +Title = HD blood sitting too long after treatment stopped by user alarm (>5 min) +Message = HD [126] -Title = Blood Stop: Dialyzer Blood Leak -Message = A blood leak has been detected. Treatment must end. +Title = HD blood leak detected alarm +Message = HD [127] -Title = Blood Stop: Venous Pres. Low -Message = Venous pressure is low.\n- Check to be sure your blue venous connections are secure.\n- Check that your venous access is connected and secured \nproperly. +Title = HD venous pressure too low during treatment +Message = HD [128] -Title = Blood Stop: Venous Air Bubble -Message = Venous air bubble detected indicating failure of air trap \ncontrol system.\n- Treatment must be terminated without option for rinseback.\n- Check access for dislodgement. +Title = HD venous air bubble detected alarm +Message = HD [129] -Title = +Title = Available for use Message = [130] -Title = Blood Stop: Venous Pres. High -Message = Venous pressure is high.\n- Check for access or patient discomfort.\n- Resolve access issue if applicable.\n- Check that there are no kinks or clots in the tubing.\n- Unkink the lines if applicable.\n- End treatment and do not return blood if clots are present. +Title = HD venous pressure too high during treatment +Message = HD [131] -Title = Blood Stop: Arterial Pres. Low -Message = Arterial pressure is low.\n- Check that the access is properly connected and secured.\n- Resolve access issue if applicable.\n- Check to be sure the red arterial connections are secure.\n- Check that there are no kinks or clots in the tubing.\n- Unkink lines if applicable.\n- End treatment and do not return blood if clots are present. +Title = HD arterial pressure too low during treatment +Message = HD [132] -Title = Blood Stop: Arterial Pres. High -Message = Arterial pressure is high.\n- Check that the access is properly connected and secured.\n- Resolve access issue if applicable.\n- Check to be sure your red arterial connections are secure.\n- Check that there are no kinks or clots in the tubing.\n- Unkink lines if applicable.\n- End treatment and do not return blood if clots are present. +Title = HD arterial pressure too high during treatment +Message = HD [133] -Title = DG Fault: Fluid Leak in DG -Message = Fluid leak detected in Dialysate Generation Delivery Device.\n-Treatment must be terminated.\n- Shut off water source and disconnect water and \nelectrical connections from system.\n- Call service to schedule a repair. +Title = DG fluid leak detected alarm +Message = DG SRSDG 328 = [134] -Title = Blood Stop: Fluid Leak in HD -Message = Fluid leak detected in Hemodialysis Delivery device.\n- If in treatment, BLOOD STOPPED.\n-Identify and correct the cause of the spill.\n- Clean up the spill and dry leak sensor.\n- If in treatment, resume treatment. +Title = HD fluid leak detected alarm +Message = HD [135] -Title = Blood Stop: HD Shock Detected -Message = Excessive movement detected with Hemodialysis Delivery \ndevice.\n- Confirm the device is stationary and level before continuing. +Title = HD experienced large acceleration +Message = HD [136] -Title = Dial. Gen: Shock-Vibration -Message = Excessive movement detected with Dialysis Generation \ndevice.\n- Treatment is paused.\n- Confirm the device is stationary and level before continuing. +Title = DG experienced large acceleration +Message = DG SRSDG 327 = [137] -Title = Blood Stop: HD Tilted -Message = Excessive tilt detected with Hemodialysis Delivery device.\n- Confirm the device is stationary and level before continuing. +Title = HD tilt exceeds maximum +Message = HD [138] -Title = Dial. Gen: Tilt -Message = Excessive tilt detected with Dialysis Generation device.\n- Treatment is paused.\n-Confirm the device is stationary and level before continuing. +Title = DG tilt exceeds maximum +Message = DG SRSDG 326 = [139] -Title = Loss of AC Power -Message = Power has been lost. Check all electrical connections.\n- The display and CPU will run off of the battery until \npower returns. +Title = HD AC power lost alarm +Message = HD [140] -Title = Loss of DG Comm (Timeout) -Message = Communication failure with Dialysis Generator.\n-Treatment must be terminated.\n- Ensure all cords are securely connected. +Title = HD DG communication timeout +Message = HD [141] -Title = Blood Stop: Air Trap Fill -Message = Failure to fill the Air Trap.\n- Treatment must be terminated without option for rinseback.\n- Check access for dislodgement. +Title = HD air trap fill timeout during treatment +Message = HD [142] -Title = Blood Stop: Blood Pump Occlusion -Message = Occlusion detected after the blood pump.\n- Check for clots or kinks around the dialyzer and in the \nvenous line.\n- Resolve access issue if applicable.\n- End treatment and do not return blood if clots are present.\n- Check for access or patient discomfort.\n- Unkink the lines if applicable. +Title = HD blood pump occlusion detected +Message = HD [143] -Title = DG Fault: TRo TDi Delta -Message = Call service to schedule a repair. +Title = DG dialysate temperature sensors out of range +Message = DG SRSDG 912 = [144] -Title = Cleaning: Inlet Water Cond High -Message = Cleaning Mode Inlet water conductivity too high.\n- Cleaning mode process has terminated \n- Check inlet water before restarting cleaning mode. +Title = DG cleaning mode inlet water conductivity out of high range. +Message = DG SRSDG 1066 SRSDG 1054 SRSDG 970 = [145] -Title = Dial. Gen: Acid Conc. Cond. -Message = Acid concentrate conductivity during prime is out of range.\n- Check correct acid concentrate is connected and full.\n- Resume to reprime concentrate. +Title = DG concentrate conductivity after adding acid out of range alarm +Message = DG SRSDG 846 = [146] -Title = DG POST: DG RTC Timer -Message = Call service to schedule a repair. +Title = DG RTC or timer accuracy failure. +Message = DG SRSDG 312 = [147] -Title = Dial. Gen: Dialysate not ready -Message = Dialysate is not yet ready.\n- Treatment is paused and will be ready to resume when \ndialysate is ready for use. +Title = DG wait for the DG to produce dialysate +Message = DG SRSDG 398 = [148] -Title = Cleaning: Inlet Water Temp High -Message = Cleaning Mode Inlet water temperature too high.\n- Cleaning mode process has terminated.\n- Check inlet water before restarting cleaning mode. +Title = DG Cleaning mode inlet water temperature too high +Message = DG SRSDG 1065 SRSDG 1053 SRSDG 969 = [149] -Title = HD Fault: WD Error -Message = Call service to schedule a repair. +Title = HD watchdog expired +Message = HD [150] -Title = Dial. Gen: Inlet Water Cond High -Message = Inlet water conductivity is high.\n- Treatment is paused.\n- Check the incoming water supply. +Title = DG inlet water conductivity in high range +Message = DG SRSDG 391 = [151] -Title = Dial. Gen: Inlet Water Cond Low -Message = Inlet water conductivity is low.\n- Treatment is paused.\n- Check the incoming water supply. +Title = DG inlet water conductivity in low range +Message = DG SRSDG 826 = [152] -Title = Dial. Gen: Inlet Water Pres Low -Message = Inlet water pressure is low.\n- Treatment is paused.\n- Check the incoming water supply. +Title = DG inlet water pressure in low range +Message = DG SRSDG 417 = [153] -Title = Process: Pre-Tx Terminated -Message = Pre-Treatment timeout.\n- Patient was not connected to device\n- Pre-Treatment has been terminated\n- Proceed to end treatment to remove cartridge from system. +Title = HD prime completed high priority alarm +Message = HD [154] -Title = Cleaning: Inlet Water Cond Low -Message = Cleaning Mode Inlet water conductivity too low.\n- Cleaning mode process has terminated \n- Check inlet water before restarting cleaning mode. +Title = DG cleaning mode inlet water conductivity out of low range. +Message = DG SRSDG 1067 SRSDG 1055 SRSDG 971 = [155] -Title = Loss of DG Comm (Reservoir) -Message = Communication failure with Dialysis Generator.\n-Treatment must be terminated.\n- Ensure all cords are securely connected. +Title = HD No reservoirs data message receive at least once every 2 seconds +Message = HD [156] -Title = Loss of DG Comm (Op Mode) -Message = Communication failure with Dialysis Generator.\n-Treatment must be terminated.\n- Ensure all cords are securely connected. +Title = HD No DG operation mode message receive at least once every 2 seconds +Message = HD [157] -Title = Cleaning: Chem Disinf PAA Prime -Message = Unable to sense proper chemical disinfectant.\n- Cleaning mode process has terminated.\n- Check that proper chemical disinfectant is connected to the \nbicarb port.\n- Check chemical disinfectant bottle is not empty. +Title = DG chemical disinfect prime acid line timeout. +Message = DG SRSDG 988 = [158] -Title = Dial. Gen: Inlet Water Temp Low -Message = Inlet water temperature is low.\n- Treatment is paused.\n- Check the incoming water supply. +Title = DG inlet water temperature is in the low range +Message = DG SRSDG 408 = [159] -Title = Cleaning: Chem Disinf Connect Cap -Message = Remove chemical disinfectant connection and close cap. +Title = DG chemical disinfect flush remove acid and close the concentrate cap. +Message = DG SRSDG 1044 = [160] -Title = HD Fault: BP Rotor Max Speed -Message = Call service to schedule a repair. +Title = HD blood pump rotor speed too high +Message = HD [161] -Title = DG Fault: HD-DG Comm -Message = Call service to schedule a repair. +Title = DG comm too many bad CRCs +Message = DG SRSDG 122 = [162] -Title = DG Fault: Proc-FPGA Clock -Message = Call service to schedule a repair. +Title = DG FPGA clock speed check failure. +Message = DG SRSDG 867 = [163] -Title = Dial. Gen: UF Rate Check -Message = Ultrafiltration control detected and incorrect rate.\n- This can be caused by excessive movement of system\n(shock/vibration)\n- Check system is stable and level\n- Resume and If problem persists, call service to schedule a\nrepair. +Title = HD sees primary load cell for reservoir 1 change too much too fast +Message = HD [164] -Title = Dial. Gen: UF Rate Check -Message = Ultrafiltration control detected and incorrect rate.\n- This can be caused by excessive movement of system \n(shock/vibration).\n- Check system is stable and level\n- Resume and If problem persists, call service to schedule a \nrepair. +Title = HD sees primary load cell for reservoir 2 change too much too fast +Message = HD [165] -Title = Blood Stop: Blood Clot Risk -Message = Blood pump has been off for too long.\n- Treament must be terminated. Blood clot risk.\n- NO RINSEBACK ALLOWED. +Title = HD in treatment rinseback operation timeout +Message = HD [166] -Title = +Title = Available for use Message = [167] -Title = Blood Stop: Door Open -Message = Device door is open.\n - Close door and press RESUME button to continue. +Title = HD cartridge door opened alarm +Message = HD [168] -Title = +Title = Available for use Message = [169] -Title = DG Fault: Dialysate Flow Sens Rg -Message = Call service to schedule a repair. +Title = DG Dialysate flow rate out of maximum range +Message = DG SRSDG 643 = [170] -Title = Heparin Syringe Empty -Message = Heparin syringe empty.\n- Treatment will continue\n- If additional heparin is required to complete treatment, \nadminister manually. +Title = HD syringe empty alarm +Message = HD [171] -Title = Process: Pre-Tx Hep. Pump Occ. -Message = Heparin pump occlusion detected.\n- Check heparin line is unclamped.\n- Check there are no kinks in the heparin line. +Title = HD syringe pump occlusion alarm +Message = HD [172] -Title = Process: Pre-Tx Not Enough Hep. -Message = Not enough heparin is available for treatment.\n- Check if syringe pump is touching syringe plunger.\n- If syringe pump is touching syringe plunger, end treatment.\n- If syringe pump is not touching syringe plunger, reload \nsyringe with enough heparin. +Title = HD syringe pump not enough Heparin alarm +Message = HD [173] -Title = HD Fault: RTC Config -Message = Call service to schedule a repair. +Title = HD RTC configuration error +Message = HD [174] -Title = HD POST: HD RTC Timer -Message = Call service to schedule a repair. +Title = HD RTC or timer accuracy failure +Message = HD [175] -Title = HD Fault: Pump Commutation Err -Message = Call service to schedule a repair. +Title = HD pump direction status error +Message = HD [176] -Title = +Title = HD dialysate temperature above high safety range Message = [177] -Title = DG Fault: Software Invalid State -Message = Call service to schedule a repair. +Title = DG software fault. Software found itself in an unexpected state +Message = DG SRSDG 919 = [178] -Title = HD Fault: UI-Proc Comm -Message = Call service to schedule a repair. +Title = HD communication timeout +Message = UI = SRSUI 1066 [179] -Title = DG Fault: FPGA Com -Message = Call service to schedule a repair. +Title = DG FPGA communication down for too long +Message = DG SRSDG 605 = [180] -Title = DG Fault: RO Flow Sensor Range -Message = Call service to schedule a repair. +Title = DG RO flow out of maximum range +Message = DG SRSDG 883 = [181] -Title = DG Fault: Tare Out of Range -Message = Call service to schedule a repair. +Title = DG load cells weight out of range for tare +Message = DG SRSDG 849 SRSDG 838 = [182] -Title = DG POST: LC Cal -Message = Call service to schedule a repair. +Title = DG load cells invalid calibration +Message = DG SRSDG 162 = [183] -Title = Cleaning: Invalid Resv Transfer -Message = Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists, call service to schedule a repair. +Title = DG invalid load cell value +Message = DG SRSDG 851 = [184] -Title = DG Fault: UVi Error -Message = Call service to schedule a repair. +Title = DG inlet UV reactor not healthy +Message = DG SRSDG 559 = [185] -Title = DG Alarm (Low): Fan Speed -Message = Fan failure.\n- Check that the fans inlets are not blocked or obstructed. +Title = DG fan RPM out of range +Message = DG SRSDG 628 = [186] -Title = DG Fault: CP1/CP2 Fault -Message = Call service to schedule a repair. +Title = DG concentrate pump fault +Message = DG SRSDG 891 = [187] -Title = DG Fault: CP1 Speed Fault -Message = Call service to schedule a repair. +Title = DG concentrate pump CP1 speed control error +Message = DG SRSDG 905 = [188] -Title = DG Fault: CP2 Speed Fault -Message = Call service to schedule a repair. +Title = DG concentrate pump CP2 speed control error +Message = DG SRSDG 906 = [189] -Title = DG Fault: DRP Speed Fault -Message = Call service to schedule a repair. +Title = DG drain pump RPM out of range +Message = DG SRSDG 448 = [190] -Title = DG Fault: DRP Speed Not Off -Message = Call service to schedule a repair. +Title = DG drain pump off fault +Message = DG [191] -Title = DG Fault: RO Flow High -Message = Call service to schedule a repair. +Title = DG flow rate out of upper range +Message = DG SRSDG 885 = [192] -Title = DG Fault: RO Flow Low -Message = Call service to schedule a repair. +Title = DG flow rate out of lower range +Message = DG SRSDG 945 = [193] -Title = +Title = HD dialysate temperature out of low safety range. Message = [194] -Title = DG Fault: RO Driver Feedback -Message = Call service to schedule a repair. +Title = DG RO pump duty cycle out of range +Message = DG SRSDG 881 = [195] -Title = DG Fault: RO Pump High Pressure -Message = Call service to schedule a repair. +Title = DG RO pump pressure out of range +Message = DG SRSDG 925 = [196] -Title = DG Fault: CPi/CPo Comm -Message = Call service to schedule a repair. +Title = DG CPi/CPo sensors FPGA fault +Message = DG SRSDG 955 = [197] -Title = DG Fault: CD1/CD2 Comm -Message = Call service to schedule a repair. +Title = DG CD1/CD2 sensors FPGA fault +Message = DG SRSDG 956 = [198] -Title = DG Fault: HP On With No Flow -Message = Call service to schedule a repair. +Title = DG RO flow too low while primary heater is on +Message = DG SRSDG 872 = [199] -Title = DG Fault: HR On With No Flow -Message = Call service to schedule a repair. +Title = DG Dialysate flow too low while trimmer heater is on +Message = DG SRSDG 871 = [200] -Title = DG Fault: Thermistor Range -Message = Call service to schedule a repair. +Title = DG thermistors/sensors temperature out of range +Message = DG SRSDG 178 = [201] -Title = Process: Pre-Tx Wet Self-Test -Message = Self-test has detected a problem in the dialysate flow \nmeasurement or there is a leak in the dialysate in/out lines.\n- The cartridge should be primed\n- Check cartridge installation on to machine\n- If problem persists, terminate pre-treatment and restart \nwith a new cartridge. +Title = HD pre-treatment mode wet self-test lc vs FMD failure +Message = HD [202] -Title = Process: Pre-Tx Dry Self-Test -Message = Self-test has detected blood circuit pressure cannot be \nrelieved.\n- Check PBo connection to HD for kinks\n -Check PBo transducer protector for occlusion\n- If problem persists, install a new cartridge and \nPBo transducer protector. +Title = HD pre-treatment mode dry pressure normal self-test failure +Message = HD [203] -Title = +Title = Available for use Message = [204] -Title = DG Fault: RO Rejection -Message = Call service to schedule a repair. +Title = DG RO rejection ratio out of range +Message = DG SRSDG 429 = [205] -Title = DG Fault: Cond Sensors Error -Message = Call service to schedule a repair. +Title = DG conductivity sensor fault +Message = DG SRSDG 913 = [206] -Title = DG Fault: Reservoir Fill Timeout -Message = Call service to schedule a repair. +Title = DG dialysate fill runs out of time +Message = DG SRSDG 437 = [207] -Title = DG Fault: FMP Flow Rate Error -Message = Call service to schedule a repair. +Title = DG flow meter check failure alarm +Message = DG SRSDG 240 = [208] -Title = Blood Stop: Venous Pres. High -Message = Venous pressure is high.\n- Check for access or patient discomfort.\n- Resolve access issue if applicable.\n- Check that there are no kinks or clots in the tubing.\n- Unkink the lines if applicable.\n- End treatment and do not return blood if clots are present. +Title = HD venous pressure occlusion alarm +Message = HD [209] -Title = Cleaning: Flush Circ Error -Message = Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists, call service to schedule a repair. +Title = DG drain circulation line timeout +Message = DG SRSDG 980 = [210] -Title = HD Alarm (Low): Battery Fault -Message = Call service to schedule a repair. +Title = HD battery pack detected an error +Message = HD [211] -Title = Blood Stopped: Warning -Message = Blood pump is stopped.\n- Resume treatment before countdown timer expires. +Title = HD blood sitting too long warning (>4 min) +Message = HD [212] -Title = Blood Stopped: Warning -Message = Blood pump is stopped.\n- Resume treatment before countdown timer expires. +Title = HD end of treatment alarm (user not acting to end treatment) +Message = HD [213] -Title = Process: Pre-Tx Prime Complete -Message = Prime of the cartridge is complete.\n- Proceed to connect to patient. +Title = HD prime completed medium priority alarm +Message = HD [214] -Title = +Title = Available for use Message = [215] -Title = +Title = Available for use Message = [216] -Title = Process: End of Dialysis Tx -Message = Dialysis Treatment has completed\n- Proceed to end treatment and rinseback. +Title = HD end treatment sub-mode timeout alarm +Message = HD [217] -Title = +Title = Available for use Message = [218] -Title = Process: Remove Syringe -Message = Syringe not removed from machine.\n- Remove heparin syringe. +Title = HD syringe detected alarm +Message = HD [219] -Title = Blood Stop: Syringe Not Detected -Message = Heparin is needed for treatment but syringe has been removed \nfrom syringe pump.\n- Install Heparin syringe. +Title = HD syringe pump syringe removed alarm +Message = HD [220] -Title = DG Fault: THD RTD Comm -Message = Call service to schedule a repair. +Title = DG THd sensors FPGA fault +Message = DG SRSDG 947 = [221] -Title = Blood Stop: Saline Bag Empty -Message = Saline bag appears empty.\n- Check saline bag and line and replace if saline bag is \nempty. +Title = HD Saline bag is empty +Message = HD [222] -Title = HD Fault: BP Occ Com -Message = Call service to schedule a repair. +Title = HD occlusion sensor FPGA fault +Message = HD [223] -Title = HD Fault: Art. Pres. Com -Message = Call service to schedule a repair. +Title = HD arterial sensor FPGA fault +Message = HD [224] -Title = Blood Stopped: Treatment Pause -Message = Treatment paused by user. +Title = HD treatment stopped by user action - pressed stop button +Message = HD [225] -Title = Process: End of Treatment -Message = Dialysis Treatment has completed\n- Proceed to end treatment and rinseback. +Title = HD end of treatment warning +Message = HD [226] -Title = Process: Pre-Tx Priming Complete -Message = Prime of the cartridge is complete.\n- Proceed to connect to patient. +Title = HD prime completed low priority alarm +Message = HD [227] -Title = +Title = Available for use Message = [228] -Title = Process: Pre-Tx Prime Timeout -Message = Blood line prime with saline timeout.\n- Check blood and dialysate lines for clamps, kinks or leaks. +Title = HD time out on prime saline purge air state. +Message = HD [229] -Title = Process: Pre-Tx Prime Timeout -Message = Dialyzer prime timeout.\n- Check blood and dialysate lines for clamps, kinks or leaks. +Title = HD prime dialysate dialyzer time out alarm +Message = HD [230] -Title = Process: Pre-Tx Prime Timeout -Message = Dialyzer prime timeout.\n- Check blood and dialysate lines for clamps, kinks or leaks. +Title = HD prime dialysate bypass time out alarm +Message = HD [231] -Title = Process: Pre-Tx Dry Self-Test -Message = Self-test has detected a leak in the circuit\n- Check blood line connections\n- Check dialysate line connections\n- Check PBo and PBa transducer protectors for occlusion.\n- Check clamps.\n- If problem persists, install a new cartridge. +Title = HD pre-treatment mode dry pressure self-test failure +Message = HD [232] -Title = Process: Pre-Tx Wet Self-Test -Message = Self-test has detected a problem in the load cell \nmeasurement or there is a leak in the dialysate in/out lines\n- The cartridge should be primed\n- Check cartridge installation onto machine\n- If problem persists, terminate pre-treatment and restart \nwith a new cartridge. +Title = HD pre-treatment mode wet self-test LC vs. LC failure +Message = HD [233] -Title = DG Fault: Baro Cal CRC -Message = Call service to schedule a repair. +Title = DG barometric sensor coefficients bad CRC +Message = DG SRSDG 964 SRSDG 949 SRSDG 1089 = [234] -Title = Dial. Gen: Inlet Water Pres High -Message = Inlet water pressure is high.\n- Treatment is paused\n- Check the incoming water supply. +Title = DG inlet water pressure in high range. +Message = DG SRSDG 1037 = [235] -Title = Process: Rinseback Complete -Message = Rinseback has been completed. +Title = HD in treatment stopped sub-mode after rinseback completed (no escalation) +Message = HD [236] -Title = Process: Pre-Tx Dry Self-Test -Message = Self-test has detected fluid in the cartridge.\n- Cartridges are single-use only\n- Install new cartridge to resume. +Title = HD needs new cartridge to be installed +Message = HD [237] -Title = Process: Pre-Tx Prime Timeout -Message = Dialyzer prime timeout.\n- Check blood and dialysate lines for clamps, kinks or leaks. +Title = HD prime saline dialyzer time out alarm +Message = HD [238] -Title = Process: Pre-Tx Dry Self-Test -Message = Self-test has detected cartridge is not installed.\n- Check that a cartridge is properly installed. +Title = HD no cartridge loaded or installed improperly alarm +Message = HD [239] -Title = Process: Post-Tx Remove Cartridge -Message = Cartridge not unloaded, or unloaded improperly.\n- Check that the cartridge has been removed. +Title = HD fail to remove cartridge alarm +Message = HD [240] -Title = Dial. Gen: Bicarb Conc. Cond. -Message = Bicarbonate conductivity during prime is out of range.\n- Check correct concentrate is connected and full.\n- Resume to reprime concentrate. +Title = DG bicarb conductivity out of range during bicarb pump check alarm +Message = DG SRSDG 482 = [241] -Title = Cleaning: Resv Drain Timeout -Message = Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists, call service to schedule a repair. +Title = DG reservoir drain time out +Message = DG SRSDG 848 SRSDG 90 SRSDG 561 @@ -1102,8 +1102,8 @@ SRSDG 1034 = [242] -Title = Cleaning: Resv Fill Timeout -Message = Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists, call service to schedule a repair. +Title = DG reservoir fill time out +Message = DG SRSDG 850 SRSDG 573 SRSDG 574 @@ -1124,373 +1124,373 @@ SRSDG 1024 = [243] -Title = Cleaning: Fluid Loss Detected -Message = Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists, call service to schedule a repair. +Title = DG reservoir leak time out +Message = DG SRSDG 853 = [244] -Title = Cleaning: Temp Sensor Check -Message = Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists, call service to schedule a repair. +Title = DG cleaning mode temperature sensors difference out of range +Message = DG SRSDG 852 = [245] -Title = Cleaning: Heat Disinfect Temp TO -Message = Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists, call service to schedule a repair. +Title = DG heat disinfect target temperature time out (could not reach to temperature) +Message = DG SRSDG 854 = [246] -Title = Cleaning: RO Water Cond Error -Message = Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists, call service to schedule a repair. +Title = DG cleaning mode conductivity sensors out of range +Message = DG [247] -Title = +Title = Alarm Id available Message = [248] -Title = Cleaning: Chem Disinfect Proc -Message = Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists, call service to schedule a repair. +Title = DG chemical disinfect could not reach to target temperature out of range +Message = DG [249] -Title = Cleaning: Chem Disinf PAA Cond -Message = Unable to sense proper chemical disinfectant.\n- Cleaning mode process has terminated.\n- Check that proper chemical disinfectant is connected to the \nbicarb port.\n- Check chemical disinfectant bottle is not empty. +Title = DG chemical disinfect target conductivity out of range +Message = DG SRSDG 992 = [250] -Title = Cleaning: Chem Disinf Connect PAA -Message = Connect chemical disinfectant bottle to bicarb port. +Title = DG chemical disinfect insert acid and remove the concentrate cap +Message = DG SRSDG 1046 = [251] -Title = HD POST: Sys Rec NVRAM CRC -Message = Call service to schedule a repair. +Title = HD invalid system record +Message = HD [252] -Title = HD POST: Serv Rec NVRAM CRC -Message = Call service to schedule a repair. +Title = HD invalid service record +Message = HD [253] -Title = DG POST: Sys Rec NVRAM CRC -Message = Call service to schedule a repair. +Title = DG invalid system record +Message = DG SRSDG 609 = [254] -Title = DG POST: Serv Rec NVRAM CRC -Message = Call service to schedule a repair. +Title = DG invalid service record +Message = DG SRSDG 610 = [255] -Title = HD POST: UI Compatibility -Message = Call service to schedule a repair. +Title = HD and UI software builds are not compatible +Message = HD [256] -Title = Cleaning: Chem Flush In Progress -Message = Chemical disinfect flush in progress\n- Please wait for the process to complete\n- Treatment will not be able to be started until process \ncompletes.\n- Process may be terminated by pressing the HD stop button. +Title = HD processor is in Disinfect Chemical Flush mode +Message = HD = SRSUI 497 [257] -Title = +Title = Alarm ID available for use Message = [258] -Title = +Title = Alarm Id available Message = [259] -Title = HD Fault: Temp Sensors Error -Message = Call service to schedule a repair. +Title = HD temperatures out of range +Message = HD [260] -Title = HD POST: UI Image -Message = Call service to schedule a repair. +Title = HD UI POST Application Integrity (Sha256Sum) failure +Message = UI HD = SRSUI 1067 [261] -Title = HD POST: UI CAN Driver -Message = Call service to schedule a repair. +Title = HD UI POST CANBus failure +Message = UI HD = SRSUI 1068 [262] -Title = HD POST: UI Disp Driver -Message = Call service to schedule a repair. +Title = HD UI POST Display failure +Message = UI HD = SRSUI 1069 [263] -Title = HD POST: UI Touch Driver -Message = Call service to schedule a repair. +Title = HD UI POST Touch failure +Message = UI HD = SRSUI 1070 [264] -Title = HD POST: UI SD-Card -Message = SD-Card Failure \n- Power cycle the system.\n- Call service to schedule a repair if problem persists. +Title = HD UI POST SD-Card failure +Message = UI HD = SRSUI 1071 [265] -Title = HD POST: UI RTC -Message = Call service to schedule a repair. +Title = HD UI POST RTC failure +Message = UI HD = SRSUI 1072 [266] -Title = HD POST: UI WiFi -Message = Call service to schedule a repair. +Title = HD UI POST WiFi failure +Message = UI HD = SRSUI 1073 [267] -Title = HD POST: UI Bluetooth -Message = Call service to schedule a repair. +Title = HD UI POST Bluetooth failure +Message = UI HD = SRSUI 1074 [268] -Title = HD POST: UI Ethernet -Message = Call service to schedule a repair. +Title = HD UI POST Ethernet failure +Message = UI HD = SRSUI 1075 [269] -Title = HD POST: UI Sound -Message = Call service to schedule a repair. +Title = HD UI POST Sound failure +Message = UI HD = SRSUI 1076 [270] -Title = HD POST: Proc Safestate -Message = Call service to schedule a repair. +Title = HD POST Safety Shutdown failure +Message = HD [271] -Title = DG POST: Proc Safestate -Message = Call service to schedule a repair. +Title = DG POST Safety Shutdown failure +Message = DG SRSDG 822 = [272] -Title = HD Alarm (Low): Fan Speed -Message = Fan failure.\n- Check that the fans inlets are not blocked or obstructed. +Title = HD Fan RPM out of range +Message = HD [273] -Title = +Title = Available for use Message = [274] -Title = +Title = Available for use Message = [275] -Title = HD Fault: Arterial Press Range -Message = Call service to schedule a repair. +Title = HD arterial pressure sensor is reading out of range +Message = HD [276] -Title = HD Fault: Venous Press Range -Message = Call service to schedule a repair. +Title = HD venous pressure sensor is reading out of range +Message = HD [277] -Title = HD Fault: Occlusion Sens Range -Message = Call service to schedule a repair. +Title = HD BP occlusion sensor is reading out of range +Message = HD [278] -Title = DG Fault: Reservoir Overfill -Message = Call service to schedule a repair. +Title = HD active reservoir weight out of range. +Message = HD [279] -Title = DG Fault: Reservoir Drain -Message = Call service to schedule a repair. +Title = DG dialysate drain time out +Message = DG SRSDG 752 = [280] -Title = DG Fault: DRP Direction Fault -Message = Call service to schedule a repair. +Title = DG drain pump direction invalid +Message = DG SRSDG 888 = [281] -Title = Dial. Gen: Acid Conc. Low -Message = Acid concentrate low.\n- Replace acid concentrate bottle. +Title = Acid concentration bottle low volume alarm +Message = DG SRSDG 836 = [282] -Title = Dial. Gen: Bicarb Conc. Low -Message = Bicarbonate concentrate low.\n- Replace bicarbonate concentrate bottle. +Title = Bicarbonate concentration bottle low volume alarm +Message = DG SRSDG 837 = [283] -Title = DG Fault: LC Range -Message = Call service to schedule a repair. +Title = DG load cells weight out of range +Message = DG SRSDG 615 = [284] -Title = DG Fault: Redundant LC Check -Message = Call service to schedule a repair. +Title = DG load cells primary/back up drift out of range +Message = DG SRSDG 383 = [285] -Title = +Title = Available for use Message = [286] -Title = Cleaning: Conc Cap Removed -Message = Concentrate cap removed from DG during cleaning.\n- Cleaning Process Terminated. +Title = DG concentrate cap not in proper position +Message = DG [287] -Title = HD Fault: Proc-FPGA Clock -Message = Call service to schedule a repair. +Title = HD processor clock speed checks against FPGA clock failure +Message = HD [288] -Title = DG Fault: LC Drift Check -Message = Call service to schedule a repair. +Title = HD load cells primary/back up drift out of range +Message = HD [289] -Title = Cleaning: Dialysate Cap Removed -Message = Dialysate cap removed from DG during cleaning.\n- Cleaning Process Terminated. +Title = DG dialysate cap not closed +Message = DG SRSDG 928 = [290] -Title = HD Fault: Ven. Pres. Com -Message = Call service to schedule a repair. +Title = HD venous pressure sensor FPGA fault +Message = HD [291] -Title = Cleaning: Flush In Progress -Message = System flush in progress\n- Please wait for the process to complete.\n- Treatment will not be able to be started until process \ncompletes.\n- Process may be terminated by pressing the HD stop button. +Title = HD processor is in Disinfect Flush mode +Message = HD [292] -Title = Cleaning: Heat Disinf In Progress -Message = Heat disinfect in progress\n- Please wait for the process to complete.\n- Treatment will not be able to be started until process \ncompletes.\n- Process may be terminated by pressing the HD stop button. +Title = HD processor is in Disinfect Heat mode +Message = HD [293] -Title = Cleaning: Chem Flush In Progress -Message = Chemical disinfect flush in progress\n- Please wait for the process to complete\n- Treatment will not be able to be started until process \ncompletes.\n- Process may be terminated by pressing the HD stop button. +Title = HD processor is in Disinfect Chemical mode +Message = HD [294] -Title = +Title = Available for use Message = [295] -Title = HD POST: UI CloudSync -Message = Call service to schedule a repair. +Title = HD UI POST CloudSync failure +Message = UI HD = SRSUI 1238 [296] -Title = DG Fault: TDi RTD Comm -Message = Call service to schedule a repair. +Title = DG TDi sensors FPGA fault +Message = DG SRSDG 951 = [297] -Title = DG Fault: TRo RTD Comm -Message = Call service to schedule a repair. +Title = DG TRo sensors FPGA fault +Message = DG SRSDG 950 = [298] -Title = DG Fault: Baro Pres Comm -Message = Call service to schedule a repair. +Title = DG baro sensor FPGA fault +Message = DG SRSDG 948 = [299] -Title = DG POST: Serial Number Check -Message = Call service to schedule a repair. +Title = DG invalid serial number +Message = DG SRSDG 952 = [300] -Title = HD POST: Serial Number Check -Message = Call service to schedule a repair. +Title = HD invalid serial number +Message = HD [301] -Title = +Title = Alarm ID available Message = [302] -Title = DG Fault: Processor RAM error -Message = Call service to schedule a repair. +Title = DG processor RAM error +Message = DG SRSDG 126 = [303] -Title = DG Fault: DRP Hall Commutation -Message = Call service to schedule a repair. +Title = DG drain pump direction FPGA fault +Message = DG SRSDG 958 = [304] -Title = HD POST: Usage Rec NVRAM CRC -Message = Call service to schedule a repair. +Title = HD invalid usage record +Message = HD [305] -Title = HD Fault: Processor RAM error -Message = Call service to schedule a repair. +Title = HD processor RAM error +Message = HD [306] -Title = DG Fault: CD1 CD2 Check -Message = Call service to schedule a repair. +Title = DG CD1 CD2 check fault +Message = DG [307] -Title = Blood Stop: Loss of AC Power -Message = HD power has been lost. \n- Treatment must be terminated.\n-Check all electrical connections.\n- The display and CPU will run off of the battery until \npower returns.\n-If power is returned prior to blood stopped countdown elapses, \nrinseback will be allowed. +Title = HD AC power lost second alarm +Message = HD [308] -Title = DG Fault: CPi Comm -Message = Call service to schedule a repair. +Title = DG CPi conductivity sensor invalid character received +Message = DG SRSDG 959 = [309] -Title = DG Fault: CPo Comm -Message = Call service to schedule a repair. +Title = DG CPo conductivity sensor invalid character received +Message = DG SRSDG 960 = [310] -Title = DG Fault: CD1 Comm -Message = Call service to schedule a repair. +Title = DG CD1 conductivity sensor invalid character received +Message = DG SRSDG 962 = [311] -Title = DG Fault: CD2 Comm -Message = Call service to schedule a repair. +Title = DG CD2 conductivity sensor invalid character received +Message = DG SRSDG 961 = [312] -Title = Dial. Gen: Dialysate In Flow -Message = Dialysate in flow rate is low\n- Check dialysate line connection to the DG. +Title = HD Dialysate In flow rate to too low. +Message = HD [313] -Title = Cleaning: Inlet Water Temp Low -Message = Cleaning Mode Inlet water temperature too low.\n- Cleaning mode process has terminated.\n- Check inlet water before restarting cleaning mode. +Title = DG cleaning mode inlet water temperature too low. +Message = DG SRSDG 1064 SRSDG 1052 SRSDG 968 = [314] -Title = Cleaning: Inlet Water Press High -Message = Cleaning Mode Inlet water pressure too high.\n- Cleaning mode process has terminated.\n- Check inlet water before restarting cleaning mode. +Title = DG cleaning mode inlet water pressure too high. +Message = DG SRSDG 1063 SRSDG 1051 SRSDG 967 = [315] -Title = Cleaning: Inlet Water Press Low -Message = Cleaning Mode Inlet water pressure too low.\n- Cleaning mode process has terminated.\n- Check inlet water before restarting cleaning mode. +Title = DG cleaning mode inlet water pressure too low. +Message = DG SRSDG 1068 SRSDG 1056 SRSDG 966 = [316] -Title = DG Fault: Acid CP Pump Park -Message = Call service to schedule a repair. +Title = DG acid concentrate pump park fault. +Message = DG SRSDG 983 = [317] -Title = DG Fault: Bicarb CP Pump Park -Message = Call service to schedule a repair. +Title = DG bicarb concentrate pump part fault. +Message = DG SRSDG 984 = [318] -Title = HD Fault: Air Pump Timeout -Message = Unable to reduce fluid level.\n- Air trap may be overfilled.\n- Pressure transducer protector may be contaminated.\n- Treatment must be terminated without option for rinseback.\n- Call service to schedule a repair. +Title = HD Air Pump timeout alarm +Message = HD [319] -Title = Cleaning: Chem Residual Sampling -Message = Collect chemical residuals water sample from drain line. +Title = DG chemical disinfect flush flush sample. +Message = DG SRSDG 1040 = [320] -Title = Cleaning: Chem Residual Timeout -Message = During Chemical Disinfection Flush\n-user residual sampling timed out. +Title = DG chemical disinfect flush sample timeout. +Message = DG SRSDG 1043 = [321] -Title = DG Fault: UVo Error -Message = Call service to schedule a repair. +Title = DG outlet UV reactor not healthy +Message = DG SRSDG 1069 = [322] -Title = HD POST Alarm: UI Invalid Year -Message = Call service to schedule a repair. +Title = HD UI POST Year check failure +Message = UI HD