Modes

Clone Tools
  • last updated a few seconds ago
Constraints
Constraints: committers
 
Constraints: files
Constraints: dates
Merge remote-tracking branch 'origin/DEN-16280-stuck-in-post-treatment-when-inlet-water-alarm-appears' into develop

  1. … 5 more files in changeset.
DEN-16093-merge in to develop

  1. … 1 more file in changeset.
DEN-16093-changed prime Max time and conductivity poercent check

RESOLVED in CODE WALKTHROUGH.

RESOLVED in CODE WALKTHROUGH.

RESOLVED in CODE WALKTHROUGH.

RESOLVED in CODE WALKTHROUGH.

RESOLVED in CODE WALKTHROUGH.

RESOLVED in CODE WALKTHROUGH.

Add a blank line between declarations and code.

Add a blank line between declarations and code.

#includes are sorted. Put OperationModes.h in its proper place.

#includes are sorted. Put OperationModes.h in its proper place.

required changes are done.

required changes are done.

Consider calling a (new) function in ConcentratePumps.c that would do all of this (decides whether to accept or reject command and parks the pumps if accepting, sets reject reason code if rejecting...

Consider calling a (new) function in ConcentratePumps.c that would do all of this (decides whether to accept or reject command and parks the pumps if accepting, sets reject reason code if rejecting). Function would also create and send the cmd response message and return TRUE/FALSE which would set local result here for the ack response message below.
We should reject cmd if pumps are busy/on and/or if current DG mode is fill or fault mode.

Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 2 more files in changeset.
DEN-16250 updated doxygen comment

Merge branch 'DEN-16250-flow-check-alarm-207-when-filling-with-pause-state' into develop

DEN-15250 addressed alarm 207

DG-DEN-16093_Alarm 97 Conductivity Out OF Range Triggered ON First Fill OF Treatment
DG-DEN-16093_Alarm 97 Conductivity Out OF Range Triggered ON First Fill OF Treatment
DG-DEN-16250_Flow Check Alarm 207 When Filling With Pause State
DG-DEN-16250_Flow Check Alarm 207 When Filling With Pause State
Merged DEN-16250

  1. … 1 more file in changeset.
DEN-16250 added the FMP check flag to state transition function in mode fill

Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 1 more file in changeset.
DEN-15974 updated the state of VPo in the cleaning modes' drain to be to fill

DEN-16222 updated the heat disinfect code

DEN-16222 fixed the heat disinfect cancel water path drain R1

DG-DEN-15974_Alarm 187 Triggered During Consumables Check And During Treatment
DG-DEN-15974_Alarm 187 Triggered During Consumables Check And During Treatment
Merged DEN-15964

  1. … 4 more files in changeset.