dialin

Clone Tools
  • last updated a few seconds ago
Constraints
Constraints: committers
 
Constraints: files
Constraints: dates
Merge branch 'DEN-14175-dg_hd_dev-hd_dg_dvt-update-part-5' of ssh://dvm-linux02:7999/vv/dialin into DEN-14175-dg_hd_dev-hd_dg_dvt-update-part-5

DEN-14175 addressed the code review comments and merged staging

Merge branch 'staging' into DEN-14175-dg_hd_dev-hd_dg_dvt-update-part-5

Bamboo Commit: generated the code change report

    • -2627
    • +2627
    /tools/Code_Report.csv
Bamboo Commit: generated the code change report

Merge branch 'DEN-14197-sw-s83-mg-DIAL-212-DIAL-200' into develop

Merge branch 'DEN-14197-sw-s83-mg-DIAL-212-DIAL-200' into develop

DIAL-212: Implementation of RO feedback voltage override DIAL-202: Implementation of Dialysate fill mode total volume override. DEN-14197: Fixed fill mode broadcast interval override from not overriding the broadcast interval.

Merge branch 'staging' into DEN-14197-sw-s83-mg-DIAL-212-DIAL-200

Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

Merge branch 'DEN-14170-sw_dev_sprint_82_darren' into staging

Merge branch 'DEN-14170-sw_dev_sprint_82_darren' into develop

Merge branch 'staging' into DEN-14175-dg_hd_dev-hd_dg_dvt-update-part-5

DEN-14175 renamed the DG CPLD broadcast message

Bamboo Commit: generated the code change report

    • -0
    • +2638
    /tools/Code_Report.csv
DEN-14175 converted some of the public variables to private variables

    • -18
    • +18
    /dialin/dg/scheduled_runs_record.py
DEN-14175 made some the class variables private so they are not tracked in the diff report

    • -11
    • +11
    /dialin/hd/calibration_record.py
Merged DEN-14175

Merge branch 'DEN-14175-dg_hd_dev-hd_dg_dvt-update-part-5' into develop

DEN-14175 removed the V3 software config flags

DEN-14175 removed the HD/DG V3 software config flags. Added trimmer heater use last DC broadcast. Updated the set active reservoir command payload to include the use trimmer heater last DC

Merged DEN-14175

DEN-14175 updated the drain pump current and direction override message IDs

DEN-14175, DIAL-213 added the sensed DG valves number to enum class

DEN-14175, DIAL-213, DIAL-179 added dialin commands to override current and direction of the drain pump. Added a command to be able to override the sensed status of the DG valves.

DEN-14175 added drain pump current and direction override commands, added DG valves sensed valves states override

Merge branch 'DEN-14150-hd-dialysate-flow-estimation' into develop

DEN-14150: Added getter and override functions for dialysate inlet pump rotor count + capture of rotor count value from broadcast.

DEN-14170 Add simulator for new heparin required parameter.