dgfirmware

Clone Tools
  • last updated a few minutes ago
Constraints
Constraints: committers
 
Constraints: files
Constraints: dates
DEN-5963 addressed a code review comment

    • -1
    • +1
    /firmware/App/Controllers/Thermistors.c
DEN-5963 addressed code review comments

    • -1
    • +1
    /firmware/App/Controllers/Thermistors.c
    • -3
    • +4
    /firmware/App/Modes/ModeHeatDisinfect.c
DEN-5963 remerged staging

    • -2
    • +13
    /firmware/App/Controllers/DrainPump.c
    • -15
    • +14
    /firmware/App/Controllers/Heaters.c
    • -57
    • +152
    /firmware/App/Controllers/LoadCell.c
    • -32
    • +168
    /firmware/App/Modes/ModeStandby.c
  1. … 8 more files in changeset.
DEN-5963 addressed a code review comment

    • -3
    • +3
    /firmware/App/Modes/ModeHeatDisinfect.c
DEN-5963 addressed code review comments. Added heaters monitor

    • -55
    • +138
    /firmware/App/Controllers/Heaters.c
    • -2
    • +1
    /firmware/App/Controllers/Thermistors.c
    • -8
    • +123
    /firmware/App/Modes/ModeHeatDisinfect.c
    • -2
    • +2
    /firmware/App/Modes/ModeHeatDisinfect.h
    • -1
    • +15
    /firmware/App/Services/Reservoirs.c
DEN-5963 addressed code review comments

    • -20
    • +19
    /firmware/App/Controllers/Heaters.c
    • -0
    • +11
    /firmware/App/Controllers/LoadCell.h
    • -1
    • +12
    /firmware/App/Controllers/Pressures.h
    • -61
    • +60
    /firmware/App/Modes/ModeHeatDisinfect.c
    • -91
    • +0
    /firmware/App/Services/MessagePayloads.h
DEN-5963 addressed code review comments

DEN-7802: Added dialysate 1 liter avg conductivity check

DEN-5963 addressed code review comments

    • -3
    • +5
    /firmware/App/Modes/ModeHeatDisinfect.c
    • -15
    • +0
    /firmware/App/Services/Reservoirs.c
DEN-5963 addressed code review comments

    • -102
    • +104
    /firmware/App/Modes/ModeHeatDisinfect.c
    • -1
    • +1
    /firmware/App/Modes/ModeHeatDisinfect.h
DEN-7568 worked on mode flush

DEN-5963 addressed code review comments

    • -6
    • +10
    /firmware/App/Controllers/DrainPump.c
    • -13
    • +0
    /firmware/App/Controllers/Pressures.c
    • -30
    • +33
    /firmware/App/Modes/ModeHeatDisinfect.c
DEN-7568 added timeout conditional statements for mode flush

DEN-7568 developed and tested the flush mode

    • -196
    • +138
    /firmware/App/Controllers/ROPump.c
    • -31
    • +211
    /firmware/App/Modes/ModeFlush.c
    • -6
    • +6
    /firmware/App/Services/PIControllers.c
    • -2
    • +2
    /firmware/App/Services/PIControllers.h
DEN-7568 worked on mode flush

    • -350
    • +372
    /firmware/App/Services/Reservoirs.c
    • -39
    • +43
    /firmware/App/Services/Reservoirs.h
DEN-7802: Updated concentrate pump driver

Merge branch 'DEN-5980-non-volatile-data-management-2-of-2' into staging

DEN-5980 disabled a build switch

Merge branch 'DEN-7091-pre-treatment-mode' into staging

Merge branch 'staging' into DEN-7091-pre-treatment-mode

    • -0
    • +90
    /firmware/App/Controllers/LoadCell.c
    • -0
    • +40
    /firmware/App/Services/SystemComm.c
DEN-5963 tested and updated heat disinfect

    • -181
    • +181
    /firmware/App/Modes/ModeHeatDisinfect.c
    • -2
    • +2
    /firmware/App/Modes/ModeHeatDisinfect.h
DEN-8103: added getting calibration data to load cells driver

    • -14
    • +32
    /firmware/App/Controllers/LoadCell.c
DEN-7802: added getting calibration data to load cells driver

    • -15
    • +33
    /firmware/App/Controllers/LoadCell.c
DEN-5980 added getting calibration data to load cells driver

    • -61
    • +174
    /firmware/App/Controllers/LoadCell.c
DEN-7091: Fixed flush filter count down time

DEN-7802: Added temperature check when mixing

DEN-7091: initialize water quality check start time

DEN-5980 adddressed the code review comment

DEN-5980 addressed code review comments

DEN-5963 worked on heat disinfect mode

    • -88
    • +175
    /firmware/App/Modes/ModeHeatDisinfect.c