Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

Bamboo Commit: Updated DGCommon.h with build versions from Bamboo

Merge branch 'DEN-15802-no-dg-flow-rate-out-of-range-alarms-191-192-for-heat-disinfect-active-cool' into staging

Merge branch 'DEN-15660-test_configuration_treatment_recovery' into develop

DEN-15660 addressed the code review comments

DEN-15660 addressed the code review comments

    • -21
    • +24
    /firmware/App/Modes/ModeChemicalDisinfect.c
    • -28
    • +16
    /firmware/App/Modes/ModeGenIdle.c
DEN-15702 Check VPI Open for Inlet Conductivity, Pressure, temperature. If VPI Closed, clear alarms.

    • -8
    • +17
    /firmware/App/Controllers/Pressures.c
    • -14
    • +11
    /firmware/App/Modes/ModeStandby.c
Bamboo Commit: Updated DGCommon.h with build versions from Bamboo

Merge branch 'DEN-15660-test_configuration_treatment_recovery' into develop

DEN-15809 added code to clear the dialysate generation alarm 147

Bamboo Commit: Updated DGCommon.h with build versions from Bamboo

Merge branch 'DEN-15660-test_configuration_treatment_recovery' into develop

DEN-15809 updated the code to trigger another alarm if the empty bottle alarms have been triggered.:

Bamboo Commit: Updated DGCommon.h with build versions from Bamboo

Merge branch 'DEN-15660-test_configuration_treatment_recovery' into develop

    • -1
    • +1
    /firmware/App/Modes/ModeHeatDisinfect.c
DEN-15660, DEN-15781, added code to not check the dialysate temperature sensorswhen the dialysate flow is zero. DEN-15808, Added code to process the empty jug alarm

    • -1
    • +1
    /firmware/App/Modes/ModeHeatDisinfect.c
Bamboo Commit: Updated DGCommon.h with build versions from Bamboo

Merge branch 'DEN-15660-test_configuration_treatment_recovery' into develop

DEN-15660, DEN-15767, DEN-15781 cleaned up the SystemCommMessages.c for messages list script. Added moving average for TDi and TRo sensors for dialysate temperature drift check

Bamboo Commit: Updated DGCommon.h with build versions from Bamboo

Merge branch 'DEN-15802-no-dg-flow-rate-out-of-range-alarms-191-192-for-heat-disinfect-active-cool' into develop

DEN-15802 Correct alarm 191.192 testing based upon specific modes.

Bamboo Commit: Updated DGCommon.h with build versions from Bamboo

Merge branch 'DEN-15802-no-dg-flow-rate-out-of-range-alarms-191-192-for-heat-disinfect-active-cool' into develop

# Conflicts:

# firmware/App/DGCommon.h

    • -2
    • +2
    /firmware/App/Modes/ModeHeatDisinfect.c
STRL-15802 Add Heat Disinfect Active Cool to logic to test for 191, 192

Bamboo Commit: Updated DGCommon.h with build versions from Bamboo

Bamboo Commit: Updated DGCommon.h with build versions from Bamboo

Merge branch 'DEN-15660-test_configuration_treatment_recovery' into develop

DEN-15715 added a command to close VRD1 prior to transitioning to chemical disinfect cancel water path

    • -11
    • +11
    /firmware/App/Modes/ModeChemicalDisinfect.c
Bamboo Commit: Updated DGCommon.h with build versions from Bamboo