DENBUG-298 updated the code from staging

  1. … 18 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 18 more files in changeset.
DENBUG-311 changed the speed of persistence rotor speed for alarm to 20 seconds

DENBUG-311 changed the persistent time of alarm 38 to 20 seconds

DENBUG-299 added code to fill the air trap before pretreatment priming is complete

  1. … 1 more file in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 102 more files in changeset.
Merged release/p1b/staging

  1. … 3 more files in changeset.
DEN-17220 added the code from staging

  1. … 7 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

Merged DEN-17208

  1. … 10 more files in changeset.
DEN-17208 removed the DPi check in the check for bypass in the blood leak detector

Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 102 more files in changeset.
DENBUG-290 fixed the blood leak code

DENBUG-290, DEN-172020 added code to not trigger the blood leak alarm in saline bolus

DEN-17161 changed calcium and postassium data types from U32 to F32 in treatment logs. DENBUG-290 added code to not trigger alarms 126 and 129 in treatment recirculation

  1. … 2 more files in changeset.
DENBUG-290 updated the blood leak driver to not check for blood recover until the dialysate inlet pump is not running. Changed the rinseback target volume from 350 mL to 400 mL

  1. … 2 more files in changeset.
Merged DENBUG-285

Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 3 more files in changeset.
DENBUG-285 updated the changes from staging

  1. … 3 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 3 more files in changeset.
DENBUG-285 updated the target blood flow rates in saline bolus and treatment end

  1. … 1 more file in changeset.
DENBUG-285 fixed the VBT in air trap

Merge branch 'DENBUG-285-alarm-141-air-trap-fill-timeout' into develop

DENBUG-285 removed the VBV code in air trap

DENBUG-285 updated the code per the latest requests: 1. Reverted the VBV in airtrap. 2. Changed blood prime to 250mlPerMin and 3. Changed the min venous pressure to 0 mmHg

  1. … 1 more file in changeset.
Merged DENBUG-285

  1. … 3 more files in changeset.
DENBUG-285 added code to set the VBV to close in air trap open state

DENBUG-285 delayed closing VBT 50ms

DENBUG-285 added code to close VBV when filling the air trap

Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 14 more files in changeset.