DEN-9480 updated documentation

DEN-9480 addressed the code review comments

DEN-9480 addressed the code review comment

DEN-9480 addressed the code review comments

DEN-9480 updated the InternalADC to add the RO pump feedback duty cycle

DEN-9480, DEN-9130 aadded code to monitor the RO pump duty cycle using the feedback data from FPGA

DEN-9480 addressed the code review comments

    • -1
    • +2
    ./App/Controllers/ConductivitySensors.c
    • -1
    • +2
    ./App/Controllers/TemperatureSensors.c
  1. … 16 more files in changeset.
DEN-9480 tested RTC stop clock and drain mode

    • -0
    • +2
    ./App/Controllers/TemperatureSensors.c
DEN-9480, DEN-10788 continued working on the heaters control and added code to be able override the drain pump RPM once the pump is in the open loop mode

  1. … 3 more files in changeset.
DEN-9480 added trimmer heater states and implemented the primary heater's efficiency code

DEN-9480 added stop drain mode command and stop RTC clock command

    • -1
    • +29
    ./App/Services/SystemCommMessages.c
DEN-9480, DEN-10409 addressed the DG fault and removed the extra flow sensor check'

DEN-9480 removed the small k factor conversion of the Ro pump

DEN-10410, DEN-10648 addressed events feature's issues

DEN-9480 added the return state to all the modes' transition function

  1. … 9 more files in changeset.
DEN-9480 worked on the heaters

DEN-10583, DEN-10410 changed the sendEvent function to properly publish all the data into 4-byte data.

    • -4
    • +12
    ./App/Services/SystemCommMessages.c
DEN-9480 added events to the firmware

    • -0
    • +35
    ./App/Services/SystemCommMessages.c
DEN-9480 added a build switch to be able to use the smaller or the normal flow sensors K factor

DEN-9480 removed dg_build_history.log

DEN-9480 removed a bypass in POST to continuously go through the UV reactors POST

DEN-10521 fixed the load cells override issue

DEN-9480 modified code to test flow. DEN-10521 removed autocal code from the override function

DEN-9480 updated the RO pump flow monitor

DEN-10412 updated the concentrate pumps to convert the values to negative once the direction of the pumps i negative

    • -5
    • +16
    ./App/Controllers/ConcentratePumps.c
    • -61
    • +0
    ./App/Services/SystemCommMessages.c
DEN-9480, DEN-10419, DEN-10420 addressed the bugs in the mentioned bugs

DEN-9480 work in progress

DEN-9480 Updated the modes for testing

DEN-9480 work in progress

DEN-9480 added more comments