DENBUG-321 updated the instructions of the alarm 97

DENBUG-318 added the word max to the RO rejection ratio

DENBUG-320 removed alarms 281 and 282 which are acid and bicarb low volume alarms and the supporting override messages

DENBUG-318 added an RO rejection ratio event

DENBUG-318 added request and response messages for the RO rejection ratio from HD to DG

Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

Merged release/p1b/staging

Merged DENBUG-298

DENBUG-298 updated the code from staging

Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

Merge branch 'DENBUG-298-user-unable-to-deliver-saline-bolus-during-alarm-conditions-where-the-blood-pump-is-recirculating' into develop

DENBUG-302 added UF rate events for information

DENBUG-298 updated the compatibility number

Merge branch 'DENBUG-298-user-unable-to-deliver-saline-bolus-during-alarm-conditions-where-the-blood-pump-is-recirculating' into develop

DENBUG-302 added a new generic command

Merge branch 'DENBUG-298-user-unable-to-deliver-saline-bolus-during-alarm-conditions-where-the-blood-pump-is-recirculating' into develop

DENBUG-298 changed the alarm ranks to 110 from 10 that are not fault anymore. Created a new reject reason for saline bolus not being allowed if the alarm does not allow blood recirc or dialysate recirc

DENBUG-308 made alarms 38 and 42 recoverable

DENBUG-298 changed some of the HD alarm from fault to be recoverable

Merge branch 'DENBUG-298-user-unable-to-deliver-saline-bolus-during-alarm-conditions-where-the-blood-pump-is-recirculating' into develop

DENBUG-308 updated the alarm properties of alarm 42, dialout rotor speed to be like alarm 38, dialin rotor speed

Merge branch 'DENBUG-298-user-unable-to-deliver-saline-bolus-during-alarm-conditions-where-the-blood-pump-is-recirculating' into develop

DENBUG-299 removed alarm 273

DENBUG-299 removed alarm 273 for release 21

DENBUG-298 removed the maximum additional saline bolus reject reason

Merge branch 'DENBUG-298-user-unable-to-deliver-saline-bolus-during-alarm-conditions-where-the-blood-pump-is-recirculating' into develop

DENBUG-298 removed the saline bolus max volume state and its reject reason

DENBUG-298 reverted the compatibility for testing

DENBUG-298 added a new state in treatment stop to support saline bolus

Merge branch 'DENBUG-298-user-unable-to-deliver-saline-bolus-during-alarm-conditions-where-the-blood-pump-is-recirculating' into develop