DEN-6890: Implemented first pass of DG Fluid Leak Detector driver

DEN-6890: Implemented first pass of DG Fluid Leak Detector driver

    • -0
    • +255
    /firmware/App/Controllers/FluidLeak.c
    • -0
    • +56
    /firmware/App/Controllers/FluidLeak.h
DEN-5963 work in progress. tested cancellation path with water

    • -12
    • +29
    /firmware/App/Controllers/Heaters.c
    • -86
    • +124
    /firmware/App/Modes/ModeHeatDisinfect.c
    • -1
    • +22
    /firmware/App/Services/Reservoirs.c
    • -18
    • +0
    /firmware/App/Services/WatchdogMgmt.c
DEN-5963 added other inlet and outlet fans RPM

    • -6
    • +6
    /firmware/App/Modes/ModeHeatDisinfect.c
DEN-5963 tested heat disinfect

    • -102
    • +229
    /firmware/App/Modes/ModeHeatDisinfect.c
    • -1
    • +2
    /firmware/App/Modes/ModeHeatDisinfect.h
    • -3
    • +21
    /firmware/App/Services/WatchdogMgmt.c
DEN-7091: Added acid and bicarb tests

    • -41
    • +158
    /firmware/App/Modes/ModeFill.c
DEN-5963 worked on the heat disinfect states

    • -23
    • +23
    /firmware/App/Controllers/DrainPump.c
    • -79
    • +121
    /firmware/App/Modes/ModeHeatDisinfect.c
DEN-7091: Fixed FPGA revision

DEN-7091: Fixed drain pump conversion error when pump is off

    • -2
    • +13
    /firmware/App/Controllers/DrainPump.c
DEN-7091: Expanded fill command to accept start/stop flag

DEN-7091: Addressed code review

DEN-5963 added Ilimit to the PIControllers.c, added feedback temperature sensor to the heaters.c, worked on heat disinfect mode

    • -33
    • +57
    /firmware/App/Controllers/Heaters.c
    • -17
    • +22
    /firmware/App/Modes/ModeHeatDisinfect.c
    • -0
    • +1
    /firmware/App/Modes/ModeHeatDisinfect.h
    • -6
    • +6
    /firmware/App/Services/PIControllers.c
DEN-5963 worked on RO pump and the pre heat disinfect states

    • -90
    • +136
    /firmware/App/Controllers/ROPump.c
    • -44
    • +47
    /firmware/App/Modes/ModeHeatDisinfect.c
    • -5
    • +5
    /firmware/App/Modes/ModeHeatDisinfect.h
    • -0
    • +1
    /firmware/App/Services/PIControllers.c
    • -1
    • +2
    /firmware/App/Services/PIControllers.h
    • -0
    • +12
    /firmware/App/Services/Reservoirs.c
DEN-5963 merged staging. Worked on RO pump

    • -19
    • +17
    /firmware/App/Controllers/DrainPump.c
    • -7
    • +48
    /firmware/App/Controllers/Heaters.c
    • -6
    • +22
    /firmware/App/Controllers/Heaters.h
    • -6
    • +3
    /firmware/App/Controllers/Thermistors.c
    • -26
    • +19
    /firmware/App/Modes/ModeHeatDisinfect.c
    • -7
    • +0
    /firmware/App/Services/MessagePayloads.h
    • -20
    • +42
    /firmware/App/Services/PIControllers.c
    • -107
    • +182
    /firmware/App/Services/Reservoirs.c
DEN-5963 worked on RO pump and the drain states of heat disinfect

    • -124
    • +6
    /firmware/App/Controllers/ROPump.c
    • -3
    • +4
    /firmware/App/Modes/ModeHeatDisinfect.c
    • -1
    • +0
    /firmware/App/Services/PIControllers.h
DEN-7091: Changed startup active reservoir to 1

DEN-5963 changed the RO pump control scheme from pressure control to flow control

    • -10
    • +1
    /firmware/App/Controllers/LoadCell.h
    • -91
    • +161
    /firmware/App/Controllers/ROPump.c
    • -11
    • +11
    /firmware/App/Modes/ModeHeatDisinfect.c
    • -1
    • +0
    /firmware/App/Services/PIControllers.c
DEN-7091: Added filter flush progress data broadcast

Merge branch 'DEN-6402-hd_dev-pre-treatment-self-tests' into staging

DEN-5980 added a #define for disabling the CRC check comments

DEN-7091: Added water sample command handler

    • -26
    • +141
    /firmware/App/Modes/ModeStandby.c
DEN-5980 added or removed some of the states

    • -10
    • +1
    /firmware/App/Controllers/LoadCell.h
DEN-5980 removed old calibration commands

DEN-6402: Fixed load cell tare reset between tare requests

    • -25
    • +47
    /firmware/App/Services/PIControllers.c
DEN-5980 added more commands to send and receive NV data

    • -4
    • +28
    /firmware/App/Services/SystemComm.c
DEN-6402: Addressed code review comments

DEN-6402: Added alarm for RO pump ramp up retry fail

DEN-6402: Added flow meter check and filters for load cells

    • -9
    • +106
    /firmware/App/Controllers/LoadCell.c
    • -10
    • +3
    /firmware/App/Controllers/LoadCell.h
    • -29
    • +43
    /firmware/App/Services/Reservoirs.c
    • -25
    • +12
    /firmware/App/Services/Reservoirs.h
DEN-6402: Added change valve setting command

    • -0
    • +48
    /firmware/App/Services/Reservoirs.c
    • -6
    • +15
    /firmware/App/Services/Reservoirs.h
DEN-6402: Use reset persistent alarm timer