DEN-15973 fixed the inlet water pressure alarm. DEN-16418 added chemical flush done after chemical disinfect prior to starting RO permeate sample mode

  1. … 1 more file in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 11 more files in changeset.
DEN-15921 code clean up

Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

DEN-15867: Fix for issue where concentrate prime/test was being done twice in pre-tx.

Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 3 more files in changeset.
Merge branch 'DEN-15702-alarm-150-inlet-water-conductivity-high-does-not-disappear-on-standby-screen-when' into develop

  1. … 2 more files in changeset.
DEN-15702 Check VPI Open for Inlet Conductivity, Pressure, temperature. If VPI Closed, clear alarms.

  1. … 3 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 2 more files in changeset.
DEN-15701: handle stop DG command from HD while in standby water sampling states.

  1. … 2 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 25 more files in changeset.
DEN-15367 addressed the code review comments

  1. … 7 more files in changeset.
DEN-15367, DEN-15404 worked on the treatment recovery. Initial commit of the RO permeate sample mode

  1. … 12 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 8 more files in changeset.
DEN-15246 added more code to support different conductivity sensors calibration tables

  1. … 7 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 13 more files in changeset.
DEN-15182 removed the rejection ratio alarm from the standby mode

DEN-15182 added a pause state in standby mode for the inlet water conditions. Addressed the code review comments

  1. … 4 more files in changeset.
DEN-15182 updated the code to handle the inlet water conditions in standby mode

DEN-15166, DEN-15182 updated the voltages code and fixed the filter flush code to be able to resume after an inlet condition alarm

  1. … 1 more file in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 5 more files in changeset.
DEN-15164 changed the inlet water conditions persistenet alarm to 30 seconds

  1. … 4 more files in changeset.
DEN-15164 removed the code to close VPi in filter flush mode when the inlet water condition is out of range

  1. … 1 more file in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 12 more files in changeset.
DEN-14999 merged staging

  1. … 9 more files in changeset.
DEN-14999 updated the code based on the alarms table

  1. … 9 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 17 more files in changeset.
DEN-14999 updated the code based on the alarms table changes

  1. … 7 more files in changeset.
DEN-14999, DEN-15031 added code to receive and support different types of acid and bicarb in the treatment

  1. … 5 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 17 more files in changeset.