DialInFlow.c

Clone Tools
  • last updated a few minutes ago
Constraints
Constraints: committers
 
Constraints: files
Constraints: dates
DEN-4640: Added saline bolus alarms.

  1. … 6 more files in changeset.
DEN-4640: Added alarm for weak flow sensor signal strength. Added handling of saline bolus abort from user.

  1. … 3 more files in changeset.
Added support to broadcast and override flow sensor signal strength.

  1. … 9 more files in changeset.
DEN-4640: Minor fixes.

  1. … 3 more files in changeset.
DEN-4640: Further developed saline bolus functionality.

  1. … 12 more files in changeset.
DEN-5053: Fixed doxygen function headers for inputs/outputs details section.

  1. … 36 more files in changeset.
Bamboo Commit: Updated the Copyright with the current year and replaced tabs with 4 spaces

  1. … 60 more files in changeset.
DEN-4211: Addressed Doxygen code comments review feedback. Updated IT for Accel.c

  1. … 8 more files in changeset.
DEN-4534: More doxygen udpates.

  1. … 17 more files in changeset.
DEN-4534: Doxygen updates.

  1. … 38 more files in changeset.
DEN-4211: Updated format of @params in all modules.

  1. … 30 more files in changeset.
DEN-4211: Fixed Vectorcast math.h issue and removed band-aid macros in common.h.

  1. … 5 more files in changeset.
DEN-4211: Finished HD pumps open loop Dialin command update. Started data infrustructure for treatment parameters mode.

  1. … 15 more files in changeset.
DEN-4212: Tuned blood and dialysate flow sensors. Changed blood and dialysate pump control back to closed loop. Updated FPGA ID.

  1. … 5 more files in changeset.
DEN-4212, DEN-4217: Added accelerometer feature. Added calibration to blood and dialysate flow. Moved msg payload structures to a separate header file.

  1. … 13 more files in changeset.
Handle CAN and UART error/warning notifications. Differentiated HD from DG s/w fault. Updated some older module/function headers to latest format.

  1. … 24 more files in changeset.
Bamboo Commit: Updated the Copyright with the current year and replaced tabs with 4 spaces

  1. … 70 more files in changeset.
UT/IT updates.

Changed UF reference volume update approach from time x rate equation to accumulation of step time x rate. Fixed debug logging of event data when alarm is triggered. Updated flow test build output.

  1. … 4 more files in changeset.
Updated FPGA register map to latest HDD. Separated ramp up and ramp down rates so they can be set differently for blood and dialysate pumps.

  1. … 6 more files in changeset.
Fixed UF change verification logic. Fixed doxygen comments.

  1. … 3 more files in changeset.
Added test code that can read slow page of FPGA. Added test code for flow signal strength and occlusion sensor debug output for h/w testing. Delayed reservoir switch until after DG has flushed lines and started recirculating in order to get a more stable reading on load cells.

  1. … 7 more files in changeset.
Added minimum 1 hr treatment to settings adjustment range checks. Changed blood/dialysate inlet pump flow rate filter approach. Changed blood/dialysate inlet pump control interval to 10 sec.

  1. … 2 more files in changeset.
Addressed code review feedback.

  1. … 3 more files in changeset.
Updated UT. Addressed code review feedback.

  1. … 3 more files in changeset.
Added pump alarms and checks.

  1. … 9 more files in changeset.
Added new HD pump alarms. Started implementing new HD pump alarms.

  1. … 7 more files in changeset.
Added calculation of pump speed and direction per hall sensor count from FPGA on all 3 pumps.

  1. … 3 more files in changeset.
Added rotor speed to dialysate pumps. Updated doxygen commenting. Added CPP check settings for the HD firmware project.

  1. … 7 more files in changeset.
De-macroized some Dialin API code for Vectorcast and doxygen. Updated some IT.

  1. … 3 more files in changeset.