DEN-5053: Fixed merge conflicts w/ valves branch.

  1. … 12 more files in changeset.
DEN-4640: Added alarm for weak flow sensor signal strength. Added handling of saline bolus abort from user.

  1. … 2 more files in changeset.
DEN-4640: Addressed code review feedback.

Added support to broadcast and override flow sensor signal strength.

  1. … 5 more files in changeset.
DEN-4308 updated the doxygen documentation and ran the test script

  1. … 3 more files in changeset.
DEN-5053: Added build switch to disable alarm for air trap fill timeout.

  1. … 2 more files in changeset.
DEN-5053: Added build switch for testing where 3-way valves are always open after homing.

  1. … 4 more files in changeset.
DEN-4640: Minor fixes.

  1. … 1 more file in changeset.
DEN-5053: Increased air trap fill volume. Misc adjustments for UI workflow.

  1. … 3 more files in changeset.
DEN-4308 added another define for a larger range check in Position B during current relaxation

  1. … 1 more file in changeset.
DEN-5053: Added UT for AirTrap module.

  1. … 1 more file in changeset.
DEN-4308 addressed the code review comments and worked on development testing

  1. … 8 more files in changeset.
DEN-4640: Added saline bolus functionality.

  1. … 5 more files in changeset.
DEN-4308 Continued with development testing

DEN-4308 addressed code review comments and continued dev testing

  1. … 3 more files in changeset.
DEN-4640: Further developed saline bolus functionality.

  1. … 7 more files in changeset.
DEN-4640: Started saline bolus implementation. Pulled HD valves driver from other feature branch due to valve dependency for the saline bolus feature.

  1. … 8 more files in changeset.
DEN-5053: Added air trap alarms. Added actuator safe state enforcement to fault mode.

  1. … 6 more files in changeset.
DEN-5053: Fixed doxygen function headers for inputs/outputs details section.

  1. … 28 more files in changeset.
DEN-5053: Updated EMC test code to use valve functions. Added Dialin command for resetting f/w processor.

  1. … 6 more files in changeset.
DEN-4308 Addressed code review comments and continued development testing

  1. … 5 more files in changeset.
DEN-5053: Addressed code review feedback. Fixes to treatment workflow messaging with UI. Added an alarm lamp sync flag to alarm status message and increased transmission rate from 2 Hz to 4 Hz to allow alarm lamp sync flag to reach UI in timely manner. Added an assertion to give compiler error if new alarm is added to enumeration and not to alarm definition table. Update FPGA UT.

  1. … 17 more files in changeset.
DEN-4308 Dev testing the code and addressing the code review comments

  1. … 3 more files in changeset.
DEN-4308 Unit tested valves.c. Added debug build switch for the valves PWM functions

  1. … 3 more files in changeset.
DEN-5053: Further updates to air trap module.

  1. … 2 more files in changeset.
DEN-4308 tested the code and updated the comments

DEN-5053: Continued development of air trap module.

DEN-5053: Start of air trap module.

  1. … 1 more file in changeset.
DEN-4308 updated the code after testing the PWM control mode

  1. … 3 more files in changeset.
Bamboo Commit: Updated the Copyright with the current year and replaced tabs with 4 spaces

  1. … 49 more files in changeset.