Moved modes and sub-modes enums to common header. Added sub-mode to HD op mode broadcast. Added current UF rate to UF rate change response to UI.

  1. … 28 more files in changeset.
Added test code that can read slow page of FPGA. Added test code for flow signal strength and occlusion sensor debug output for h/w testing. Delayed reservoir switch until after DG has flushed lines and started recirculating in order to get a more stable reading on load cells.

  1. … 5 more files in changeset.
Added build switch to run UF test with or without DG.

  1. … 2 more files in changeset.
Misc UF fixes. Changed CAN from FIQ to IRQ to see if helps with intermittent lockup.

  1. … 10 more files in changeset.
Updated dialysis sub-mode to handle two reservoirs for UF.

  1. … 4 more files in changeset.
Addressed code review feedback.

Implemented some test code of UF demo support in Standby mode. Started a state machine for treatment mode reservoir management.

  1. … 3 more files in changeset.
Added minimum 1 hr treatment to settings adjustment range checks. Changed blood/dialysate inlet pump flow rate filter approach. Changed blood/dialysate inlet pump control interval to 10 sec.

  1. … 1 more file in changeset.
Updated UT/IT for BloodFlow, Interrupts, FPGA modules.

  1. … 1 more file in changeset.
Addressed code review feedback.

  1. … 3 more files in changeset.
Updated UT. Addressed code review feedback.

  1. … 1 more file in changeset.
Added blood pump rotor max alarm.

  1. … 2 more files in changeset.
Added pump alarms and checks.

  1. … 6 more files in changeset.
Added new HD pump alarms. Started implementing new HD pump alarms.

  1. … 4 more files in changeset.
Added calculation of pump speed and direction per hall sensor count from FPGA on all 3 pumps.

  1. … 1 more file in changeset.
Added rotor speed to dialysate pumps. Updated doxygen commenting. Added CPP check settings for the HD firmware project.

  1. … 4 more files in changeset.
Added interrupt handler for rotor hall sensor edges. Handled BP rotor hall sensor edges.

  1. … 11 more files in changeset.
De-macroized some Dialin API code for Vectorcast and doxygen. Updated some IT.

Added DG messaging.

  1. … 3 more files in changeset.
Continued implementation of DGInterface module.

  1. … 1 more file in changeset.
Added new DGInterface module. Messaging for HD/DG comm.

  1. … 6 more files in changeset.
Merge branch 'master' into DEN-2390-hd-dialysate-temperature-1-of-2

  1. … 2 more files in changeset.
Code review fixes. Moved task interrupts to notifications.

  1. … 6 more files in changeset.
Added treatment settings range update message. Addressed code review feedback.

  1. … 5 more files in changeset.
Updated the Copyright with the current year and replaced tabs with 4 spaces

  1. … 4 more files in changeset.
Minor updates.

  1. … 3 more files in changeset.
Added messaging for blood/dialysate flow rate change and HD to DG dialysate temperature set points.

  1. … 6 more files in changeset.
Perparing for a merge with DEN-1906

  1. … 38 more files in changeset.
Fixes per UT and IT. Updates to UT and IT.

  1. … 4 more files in changeset.
Updated doxygen comments. Un-macro test functions and override variables in DialOutFlow module.

  1. … 4 more files in changeset.