DEN-7117: added build switch check on pump flow self-test to prevent zeroing of calibration gain while calibration functionality is still TBD.

Merge branch 'DEN-7091-pre-treatment-mode' into develop

  1. … 2 more files in changeset.
Fixed merge conflicts.

  1. … 7 more files in changeset.
DEN-7117: Finished bolus and continuous delivery operations.

  1. … 2 more files in changeset.
DEN-7091: Added build switch to skip UI interaction

  1. … 5 more files in changeset.
DEN-7091: Addressed code reviews

  1. … 2 more files in changeset.
DEN-7117: Fixed plunger seek and prime states.

DEN-7117: Added Dialin messaging and support functions.

  1. … 4 more files in changeset.
DEN-7117: Fixed error in safety volume checks.

  1. … 2 more files in changeset.
Added missing OperationModes.h to reduce CCS warning list by 1

Added check fluid leak detector state outside of INIT_MODE

DEN-7117: Updated safety volume logic for saline bolus, blood prime, and rinseback. Removed concept of a UF complete state.

  1. … 4 more files in changeset.
DEN-6890: Addressed code review comments

DEN-6890: Addressed code review comments

DEN-6890: Addressed code review comments

  1. … 1 more file in changeset.
DEN-7117: update to ramping.

DEN-7117: Updated ramping profile.

DEN-7091: Added build switches to skip self-tests

  1. … 5 more files in changeset.
DEN-7117: Continued implementation of syringe pump controller.

  1. … 1 more file in changeset.
DEN-6890: Implemented first pass of HD Fluid Leak Detector driver

  1. … 1 more file in changeset.
DEN-6890: Implemented first pass of HD Fluid Leak Detector driver

DEN-6890: Implemented first pass of HD Fluid Leak Detector driver

  1. … 2 more files in changeset.
DEN-6890: Implemented first pass of HD Fluid Leak Detector driver

  1. … 4 more files in changeset.
DEN-6890: Implemented first pass of HD Fluid Leak Detector driver

  1. … 3 more files in changeset.
DEN-6890: Implemented first pass of HD Fluid Leak Detector driver

  1. … 2 more files in changeset.
DEN-6890: Initial commit

  1. … 4 more files in changeset.
DEN-7117: Added implementation to syringe pump driver. Fixed saline bolus response msg. Fixed UF ranges given to UI.

  1. … 7 more files in changeset.
DEN-7117: Added new syringe pump module. Added FPGA module functions for syringe pump. Added broadcast function for syringe pump data msg.

  1. … 4 more files in changeset.
DEN-6372: Merge from staging pt 2.

  1. … 9 more files in changeset.
DEN-7091: Combined self-tests states and removed current min check when pumps running