CommBuffers.c

Clone Tools
  • last updated a few minutes ago
Constraints
Constraints: committers
 
Constraints: files
Constraints: dates
Perparing for a merge with DEN-1906

  1. … 46 more files in changeset.
Further implementation of UF settings change messaging and handling. Code review fixes.

  1. … 17 more files in changeset.
Added HD specific common header. Streamlined includes for Common.h and HDCommon.h.

  1. … 55 more files in changeset.
Fixed MIBSPI3 config for RTC. Code review fix.

  1. … 1 more file in changeset.
Added dialysis sub-mode. Misc fixes.

  1. … 25 more files in changeset.
Merge branch 'master' into DEN-1312-hd-dialysate-inlet-pump-drive-flow-sensor-control

  1. … 28 more files in changeset.
Minor improvements to CAN communications. +review HD-DEN-1312-1

  1. … 3 more files in changeset.
Updated PIControllers to behave in classic manner. Added more thread protection to CAN comm buffers. +review HD-DEN-1312-1

  1. … 8 more files in changeset.
Updated the Copyright with the current year and replaced tabs with 4 spaces

  1. … 64 more files in changeset.
Updated FPGA registers. Removed some CAN debug code. Removed html reports from vectorcast.

  1. … 2 more files in changeset.
Added some more CAN debug code. Minor updates to blood and dialysate pump modules.

  1. … 5 more files in changeset.
Updated flow filter in BloodFlow per discussion with Blaine. Added ADC channels for dialysate pumps. Added some debug code for CAN tranmit issue. Added GPIO for dialysate pumps to HALCoGen.

  1. … 19 more files in changeset.
Fixed white space between brackets throughout. Added some debug code to help troubleshoot comm issue. Updated power off messaging. +review HD-DEN-759-1

  1. … 84 more files in changeset.
Misc fixes to BloodFlow and AlarmMgmt modules. Scaled BloodFlow analogs. Changed cargo to payload throughout code. Updates to existing UT. +review HD-DEN-759-1

  1. … 16 more files in changeset.
Added messaging for AlarmMgmt and Bloodflow modules. +review HD-DEN-759-1

  1. … 12 more files in changeset.
Addressed code review feedback. +review HD-DEN-759-1

  1. … 11 more files in changeset.
Replaced TODOs for triggering s/w faults with actual triggers of s/w faults. +review HD-DEN-759-1

  1. … 16 more files in changeset.
Transferred the hd_sprint5 firmware to the firmware folder

  1. … 397 more files in changeset.
Transferred the hd_sprint4 firmware to the firmware folder

  1. … 397 more files in changeset.
Transferred the sprint3 firmware to the firmware folder

  1. … 379 more files in changeset.
Transferred the master branch firmware to the firmware folder. Added the VectorCAST folder to the repository

  1. … 397 more files in changeset.