Update CAN interface to test DialOutFlow module

  1. … 8 more files in changeset.
Updated the Copyright with the current year and replaced tabs with 4 spaces

  1. … 64 more files in changeset.
Added dialin messages for dialysate inlet pump. Fixes to watchdog expired fault. Updates to existing UT.

  1. … 6 more files in changeset.
Updated CAN interrupts config. Added a watchdog expired alarm. Added PWM duty cycle to blood flow broadcast.

  1. … 18 more files in changeset.
Updated flow filter in BloodFlow per discussion with Blaine. Added ADC channels for dialysate pumps. Added some debug code for CAN tranmit issue. Added GPIO for dialysate pumps to HALCoGen.

  1. … 19 more files in changeset.
Added bloodflow overrides for not yet implemented sensors. Condensed published alarms status message.

  1. … 6 more files in changeset.
Fixed white space between brackets throughout. Added some debug code to help troubleshoot comm issue. Updated power off messaging. +review HD-DEN-759-1

  1. … 84 more files in changeset.
Added place holders for 2 sensors not yet ready for BloodFlow module. Refactored IT for CPLD and SafetyShutdown modules to move from target run to MinGW run tests. Updated UT for SystemComm and SystemCommMessages modules. +review HD-DEN-759-1

  1. … 3 more files in changeset.
Added UT start for AlarmMgmt module. Finished implementing power off timeout. Added new check-in messages for DG and UI to let HD know it is still communicating. Added delay in bulk of HD powerup until UI starts communicating on CAN to prevent CAN bus error. Added PI control to flow for blood pump. +review HD-DEN-759-1

  1. … 15 more files in changeset.
Added blood pump control per flow. Added timeout to power off request. Added more interrupt handling. Added parity checking for CAN RAM. +review HD-DEN_759-1

  1. … 12 more files in changeset.
Added dialin override support for alarm status publication interval. Added publishing of alarm status every 500ms. Updated UT for SystemComm and SystemCommMessages modules. Started UT for AlarmMgmt module. Addressed code review feedback. +review HD-DEN-759-1

  1. … 9 more files in changeset.
Added override command for blood flow data publication interval. Prevent alarm trigger/clear event publication if alarm is already triggered/cleared. Clear pending stop button if t/o alarm occurs to prevent perpetual alarm triggering. +review HD-DEN-759-1

  1. … 4 more files in changeset.
Added messaging for AlarmMgmt and Bloodflow modules. +review HD-DEN-759-1

  1. … 12 more files in changeset.
Minor fix to dialin support. +review HD-DEN-759-1

  1. … 2 more files in changeset.
Added dialin support for AlarmMgmt module. Refactored PC interface from UART to CAN. Added two CAN channels for PC interface. +review HD-DEN-759-1

  1. … 8 more files in changeset.
Added dialin functions and messages for BloodFlow module. Updated 16-bit CRC to match CCITT. +review HD-DEN-759-1

  1. … 8 more files in changeset.
Transferred the hd_sprint5 firmware to the firmware folder

  1. … 397 more files in changeset.
Transferred the hd_sprint4 firmware to the firmware folder

    • -0
    • +69
    ./SystemCommMessages.h
  1. … 397 more files in changeset.
Transferred the sprint3 firmware to the firmware folder

    • -0
    • +38
    ./SystemCommMessages.h
  1. … 379 more files in changeset.
Transferred the master branch firmware to the firmware folder. Added the VectorCAST folder to the repository

    • -0
    • +69
    ./SystemCommMessages.h
  1. … 397 more files in changeset.