LDT-802 code clean up

Bamboo Commit: Updated TDCommon.h with build versions from Bamboo.

LDT-802 upated the treatment puases module

    • -44
    • +350
    /firmware/App/Modes/StateTxPaused.c
LDT-736: updated BP stroke volume.

LDT-802 deleted the extra .gitignore file

LDT-802 updated the mode fault

LDT-736: Added basic flow estimation calculation - still needs Leahi volume per rotor rev value from Systems. Added BP homing logic to handle issue with FPGA always reporting home until it has seen a home to not home transition.

    • -32
    • +35
    /firmware/App/Controllers/BloodFlow.c
    • -6
    • +12
    /firmware/App/Drivers/PeristalticPump.c
    • -0
    • +1
    /firmware/App/Drivers/PeristalticPump.h
Merge branch 'LDT-736-general-alarm-requirements---td-' of bitbucket.org:diality-cloud/td-firmware into LDT-736-general-alarm-requirements---td-

LDT-736: Fixed bug in payload for set points broadcast msg.

    • -1
    • +1
    /firmware/App/Drivers/PeristalticPump.c
Bamboo Commit: Updated TDCommon.h with build versions from Bamboo.

Merge branch 'LDT-736-general-alarm-requirements---td-' of bitbucket.org:diality-cloud/td-firmware into LDT-736-general-alarm-requirements---td-

Fixed comparison opoerator in testSetTreatmentParameter

Bamboo Commit: Updated TDCommon.h with build versions from Bamboo.

Bamboo Commit: Updated TDCommon.h with build versions from Bamboo.

Bamboo Commit: Updated TDCommon.h with build versions from Bamboo.

Bamboo Commit: Updated TDCommon.h with build versions from Bamboo.

Merged staging

    • -125
    • +112
    /firmware/App/Services/Messaging.c
Bamboo Commit: Updated TDCommon.h with build versions from Bamboo.

LDT-736: Fixed pinch valve bug.

LDT-736: restored some debug code change made for demo.

    • -55
    • +55
    /firmware/App/Services/AlarmMgmtTD.c
Merge branch 'LDT-736-general-alarm-requirements---td-' of bitbucket.org:diality-cloud/td-firmware into LDT-736-general-alarm-requirements---td-

LDT-736: Changed BP home hall sensor polarity to match HDD.

    • -1
    • +1
    /firmware/App/Drivers/PeristalticPump.c
LDT-736 updated the code for UI demo

    • -9
    • +10
    /firmware/App/Modes/ModeTreatment.c
    • -55
    • +55
    /firmware/App/Services/AlarmMgmtTD.c
Fixed unit tests for UFrate and MIN function coverage.

Progress on Unit testing.

Updated integration testcase.

Updated Unit testcases and added Integration testcase placeholder.

LDT-736: Halved ejector extend speed to increase torque.

LDT-736: Disable ejector motor when not in active operation. Update to max pinch valve travel. Add dummy handler for UI check-in msg.

    • -0
    • +12
    /firmware/App/Controllers/Ejector.c
    • -1
    • +24
    /firmware/App/Drivers/EjectorMotor.c
LDT-736: Updates to pinch valves controller and driver per FPGA changes.

    • -11
    • +11
    /firmware/App/Controllers/Valves.c
    • -60
    • +18
    /firmware/App/Drivers/RotaryValve.c