DEN-14253 addressed the code review comments

DEN-14253 updated the code so the trimmer heater with no flow uses the raw dialysate flow prior to applying the calibration to it.

  1. … 1 more file in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

DEN-14356 addressed the code review comment

DEN-14536 updated the minimum acceptable inlet pressure

Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 11 more files in changeset.
DEN-14197: Code review changes. Pre-merge fixes.

  1. … 2 more files in changeset.
Merge branch 'staging' into DEN-14197-sw-s83-mg-pi-optimizations

  1. … 5 more files in changeset.
DEN-14197: Addressed code review comments.

DEN-14197: Addressed code review comments.

DEN-14197: Addressed code review comments.

  1. … 1 more file in changeset.
DEN-14197: Addressed code review comments.

  1. … 3 more files in changeset.
DEN-14197: Created a set pwm step limit for PI controllers. Updated RO pump profiles to contain a max set step limit. Removed unused #defines for ro pump.

  1. … 2 more files in changeset.
DEN-14197: Created a set pwm step limit for PI controllers. Updated RO pump profiles to contain a max set step limit. Removed unused defines for ro pump.

  1. … 2 more files in changeset.
DEN-14197: Removed RO pump ramp state. Tuned RO pump control coefficients.

Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 10 more files in changeset.
DEN-14197: Fixed warnings of implicit declaration.

DEN-14197: build fixes and warnings.

DEN-14197: Build fixes

DEN-14197: DIAL-212: Created measured RO pump feedback voltage override. Implemented current RO Pump profile variable.

DEN-14197: Fixed warnings regarding gen idle overrides. Fixed compiler issues when merging into develop.

  1. … 1 more file in changeset.
DEN-14197: implemented RO pump profile switching. Implemented Flow to PWM function RO pump with profiles as a parameter. Created a SW fault for PI profiles out of range.

  1. … 3 more files in changeset.
DEN-14197: Initial attempt at PI controller profiles with usage in ro pump

  1. … 2 more files in changeset.
DEN-14175 added trimmer heater use last duty cycle to the broadcast data

DEN-14175 addressed the code review comments and replaced the V3 enable software configuration flag with the hardware configuration flag from FGPA. Updated the trimmer heater's ramp state to check the use previous duty cycle flag instead of estimating the duty cycle.

  1. … 5 more files in changeset.
DEN-14175, DEN-13999 uncommented DG pressure sensors alarm

DEN-14175, DEN-13999 updated the pressure sensors persitent alarm. Added hardware configuration functions to check the status of the device (i.e. BETA, DVT)

  1. … 2 more files in changeset.
Merge branch 'staging' into DEN-14175-dg_hd_dev-hd_dg_dvt-update-part-5

DEN-14175, DIAL-213 added drain pump current and direction override commands, updated the heaters driver with the latest optimization requirements, added a DG valves sensed states override command

  1. … 4 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 3 more files in changeset.