Merge branch 'staging' into DEN-15183-in-treatment-rinseback-workflow-changes

DEN-15183: Fixed compiler warning.

DEN-15183: Addressed code review comments.

DEN-15183: Fix for DEN-15198.

    • -2
    • +10
    /firmware/App/Controllers/PresOccl.c
Bamboo Commit: Updated HDCommon.h with build versions from Bamboo

Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

Merge branch 'DEN-15189-safety-shutdown-not-activating-when-hd-valve-position-out-of-range-alarm-62-occurs' into staging

DEN-15183: Prevent alarm user options while AC power is out.

DEN-15183: Fixed DEN-15198 by not starting air trap control until treatment starts (patient connected).

    • -1
    • +0
    /firmware/App/Modes/PreTreatmentRecirc.c
Bamboo Commit: Updated HDCommon.h with build versions from Bamboo

Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

DEN-14325 addressed the code review comments

DEN-15183: Addressed code review comments. Fixed DEN-15194.

DEN-15183: Implemented updates to treatment recirculation workflow to include states for instructing user to disconnect and reconnected patient. Updated scalar for alarm audio current high gain signal. Updated alarm audio POST.

    • -4
    • +103
    /firmware/App/Modes/TreatmentRecirc.c
    • -29
    • +48
    /firmware/App/Services/AlarmMgmt.c
DEN-15189 Add activateSafetyShutdown to alarm ALARM_ID_HD_VALVE_POSITION_OUT_OF_RANGE (62) if position C

DEN-15183: indicate treatment over in treatment times broadcast if alarm preventing alarm resumption.

DEN-15183: Removed pressure limit alarm exemption for pump ramping. Address sequence issue with invert dialyzer logic DEN-15195.

    • -14
    • +0
    /firmware/App/Controllers/PresOccl.c
DEN-15183: Addressed DEN-15191 by zeroing treatment time remaining in treatment times broadcast msg if an alarm has blocked resumption of treatment.

DEN-14183: Addressed DEN-15190 by allowing rinseback option regardless of whether alarm condition is cleared.

DEN-15183: Fix for DEN-14312 (DPi running when alarm in rinseback should stop DPi).

DEN-14325 added conditions to not check for blood leak alarm, air trap illegal level alarm, and the bubble detection alarm and self test request if the pump track is open

Bamboo Commit: Updated HDCommon.h with build versions from Bamboo

Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

    • -2
    • +2
    /firmware/App/Controllers/DGInterface.c
    • -2
    • +2
    /firmware/App/Controllers/DialInFlow.c
    • -1
    • +1
    /firmware/App/Modes/ModeTreatmentParams.c
  1. … 7 more files in changeset.
Merge DEN-15105 to staging.

Merge branch 'staging' into DEN-15105-dialyzer-flip

    • -254
    • +251
    /firmware/App/Controllers/Voltages.c
DEN-15105: re-enabled a/c power loss alarm.

Bamboo Commit: Updated HDCommon.h with build versions from Bamboo

DEN-15105: Fixed dry s.t. countdown going past 0 issue.

DEN-15105: Fixed DEN-14309.

DEN-15105: Implemented pre-tx patient connection states to handle dialyzer invert.

    • -25
    • +71
    /firmware/App/Modes/ModePreTreat.c