DEN-15367 merged staging

  1. … 1 more file in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

DEN-15367 addressed a code review comment

DEN-15489 updated the code that checks for the validation dates

DEN-15367 addressed the code review comments. Added code to check the payload of the message that is received from DG to indicate that DG is ready to dispense more water in RO permeate sample mode

  1. … 4 more files in changeset.
DEN-15558: Finished restore of original BP speed during dialyzer prime.

DEN-15558: Reversed temporary change in dialyzer prime BP speed. Increased max venous pressure from 300 to 400 mmHg.

  1. … 1 more file in changeset.
DEN-15558: temporary slow down of BP during pre-tx dialyzer prime state to see if helps with blood leak issue.

Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 7 more files in changeset.
Merged staging to DEN-15278.

Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

DEN-15493 Update Rinseback flow rate range to 100-300, default 200. Old was 50-150, default 75.

DEN-15278: Addressed code review comment.

DEN-15278: no countdown timer if alarm 165 (blood sitting too long) is active.

DEN-15367 addressed the code review comments

  1. … 3 more files in changeset.
DEN-15440 added code to partial drain the reservoirs in patient connect state machine in pretreatment

DEN-15367, DEN-15404 added a message to receive the message from DG that DG is ready to dispense more fluid in RO permeate sample

  1. … 3 more files in changeset.
DEN-15278: Skip pressurize/depressurize bubble clear portion of blood side cartridge prime if wet cartridge test config is set.

DIAL-262: fixed operation event status edge cases.

DEN-15367 added a software fault to the blood leak embedded mode stat machine

  1. … 2 more files in changeset.
DEN-15367, DEN-15252, DEN-15484, DEN-15485 added code to process the cleaning modes if they were started directly from DG. Added code to be able to start RO permeate sample from UI settings. Added the blood leak detector counter to the broadcast

  1. … 6 more files in changeset.
DEN-15367 retrieved a blank line

DEN-15404, DEN-15252, DEN-15485 work in progress. Implementing code to handle cleaning modes in HD standby mode and removed the old code

  1. … 2 more files in changeset.
DEN-15404, DEN-15252, DEN-15485 work in progress. Implementing code to handle cleaning modes in HD standby mode

DEN-15404, DEN-15252 added code the HD standby to transition to the corresponding cleaning mode

Merge branch 'staging' into DEN-15367-hd_dg_test_configuration_setup

  1. … 1 more file in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 1 more file in changeset.
DEN-15314 changed the direction of the test configuration

DEN-15314: Added stall check to syringe prime operation. Extended dialysate bypass prime timeout and added a little histeresis to exit criteria for bypass prime state.

  1. … 1 more file in changeset.
DEN-15314 added a test configuration to be able to do a one minute treatment