Added UT for pressure/occlusion module and PI controllers module. Updated UT/IT. Minor fixes per UT/IT.

  1. … 6 more files in changeset.
CAN ACK fixes. Updates to UT for ACKs.

  1. … 2 more files in changeset.
Added new PresOccl, Dialysis, and TreatmentStop modules. Updated test scripts for system communication modules.

  1. … 16 more files in changeset.
Added new alarm for no CAN ACK on message.

  1. … 3 more files in changeset.
Tuned pump control. Fixed PIController anti-windup. Added some temporary debug code. Added feature to CAN for messages that require an ACK.

  1. … 15 more files in changeset.
Merge branch 'master' into DEN-1312-hd-dialysate-inlet-pump-drive-flow-sensor-control

  1. … 28 more files in changeset.
Updated PIControllers to behave in classic manner. Added more thread protection to CAN comm buffers. +review HD-DEN-1312-1

  1. … 8 more files in changeset.
Updated BloodFlow and DialInFlow modules per UT. Added new UT for DialInFlow.

  1. … 3 more files in changeset.
Updated the Copyright with the current year and replaced tabs with 4 spaces

  1. … 64 more files in changeset.
Fixed high priority alarm lamp blink frequency. Added alarm functionality for silence, escalation, and flags. Added a new boolean flag for whether there is at least one alarm pending escalation.

  1. … 3 more files in changeset.
Updated CAN interrupts config. Added a watchdog expired alarm. Added PWM duty cycle to blood flow broadcast.

  1. … 18 more files in changeset.
Added DialInFlow and DialOutUF modules. Added alarms associated with dialysate pumps.

  1. … 5 more files in changeset.
Started new UT for BloodFlow module. Finished UT for AlarmMgmt module. Fixed issues discovered during UT. +review HD-DEN-759-1

  1. … 5 more files in changeset.
Addressed some code review feedback. Added some checks to BloodFlow monitor function per requirements. +review HD-DEN-759-1

  1. … 3 more files in changeset.
Added UT start for AlarmMgmt module. Finished implementing power off timeout. Added new check-in messages for DG and UI to let HD know it is still communicating. Added delay in bulk of HD powerup until UI starts communicating on CAN to prevent CAN bus error. Added PI control to flow for blood pump. +review HD-DEN-759-1

  1. … 15 more files in changeset.
Added dialin override support for alarm status publication interval. Added publishing of alarm status every 500ms. Updated UT for SystemComm and SystemCommMessages modules. Started UT for AlarmMgmt module. Addressed code review feedback. +review HD-DEN-759-1

  1. … 9 more files in changeset.
Misc fixes to BloodFlow and AlarmMgmt modules. Scaled BloodFlow analogs. Changed cargo to payload throughout code. Updates to existing UT. +review HD-DEN-759-1

  1. … 16 more files in changeset.
Added messaging for AlarmMgmt and Bloodflow modules. +review HD-DEN-759-1

  1. … 12 more files in changeset.
Addressed code review feedback. +review HD-DEN-759-1

  1. … 11 more files in changeset.
Replaced TODOs for triggering s/w faults with actual triggers of s/w faults. +review HD-DEN-759-1

  1. … 16 more files in changeset.
Added dialin support for AlarmMgmt module. Refactored PC interface from UART to CAN. Added two CAN channels for PC interface. +review HD-DEN-759-1

  1. … 8 more files in changeset.
Added a no data type to alarm data types enum.

Added AlarmMgmt module. Added a new timer function to calculate time since a given start time.

  1. … 7 more files in changeset.