firmware

Clone Tools
  • last updated a few seconds ago
Constraints
Constraints: committers
 
Constraints: files
Constraints: dates
DEN-8030 updated the documentation

DEN-8030 adderessed a code review comment

DEN-8030 addressed code review comments

DEN-8030 addressed code review comments

    • -17
    • +18
    ./App/Modes/ModeChemicalDisinfect.c
DEN-8030 addressed code review comments and added concentrate pumps to heat disinfect

    • -1
    • +14
    ./App/Controllers/TemperatureSensors.c
    • -33
    • +19
    ./App/Modes/ModeChemicalDisinfect.c
    • -131
    • +101
    ./App/Modes/ModeHeatDisinfect.c
DEN-8030 addressed code review comments

    • -4
    • +17
    ./App/Modes/ModeChemicalDisinfect.c
DEN-8030 addressed code review comments

    • -0
    • +1
    ./App/Controllers/TemperatureSensors.h
DEN-8030 merged staging

    • -10
    • +5
    ./App/Controllers/TemperatureSensors.c
  1. … 7 more files in changeset.
DEN-8030 added a more code to the cooling stage of the RO filter in heat disinfect

    • -69
    • +130
    ./App/Modes/ModeHeatDisinfect.c
DEN-7605: Local merge w/ staging.

    • -18
    • +44
    ./App/Controllers/TemperatureSensors.c
    • -252
    • +254
    ./App/Services/Reservoirs.c
    • -0
    • +63
    ./App/Services/SystemCommMessages.c
DEN-7605: Re-ordered DG POST tests. Fixed comments.

DEN-8030 updated the drain pump RPM conversion

DEN-7605: Removed obsolete code.

DEN-7605: Minor fixes.

    • -2
    • +2
    ./App/Controllers/TemperatureSensors.c
DEN-8030 added UI states to heat disinfect. Changed the heaters control.

DEN-8030: Updated heater PWM limits for V3.

DEN-8030 tested modes and continued developing chemical disinfect

    • -6
    • +53
    ./App/Controllers/TemperatureSensors.c
    • -137
    • +342
    ./App/Modes/ModeChemicalDisinfect.c
    • -114
    • +26
    ./App/Modes/ModeHeatDisinfect.c
    • -0
    • +56
    ./App/Services/SystemCommMessages.c
DEN-7605: Addressed code review feedback.

DEN-7605: Added support for UI clock sync.

    • -0
    • +45
    ./App/Services/SystemCommMessages.c
DEN-7605: Fixed merge conflicts.

    • -3
    • +3
    ./App/Controllers/TemperatureSensors.c
DEN-7605: Added POST messaging.

    • -0
    • +61
    ./App/Services/SystemCommMessages.c
DEN-7605: Added tare state to drain mode to allow time for reservoir to settle first.

DEN-7605: Addressed code review feedback.

DEN-7605: Added delays to drain mode.

DEN-7605: Added options to valves and pumps to delay changes in state.

DEN-7605: Initialize fluid leak override structure on power up.

DEN-8030 fixed load cells tare

DEN-8030 added more logic to check the load cells value during tare

DEN-7605: Pulled in V3 valve changes from chem disinfect branch.

DEN-8030 fixed fluid leak detector