DEN-6372: Added alarm property that can prevent dialysate re-circulation while that alarm is active.

Added blood prime sub-mode states enum. Added new blood prime volume check alarm. Added new blood prime status message.

  1. … 2 more files in changeset.
Fixed merge conflicts.

  1. … 1 more file in changeset.
DEN-6372: Added new Treatment End sub-mode module.

  1. … 1 more file in changeset.
DEN-6402: Added new alarm for no cartridge loaded

  1. … 1 more file in changeset.
Fixed comment alignment.

DEN-6372: fixed merge conflicts.

DEN-6372: Added rinseback delivery volume alarm.

DEN-6402: Added pre-treatment home setup state and more alarms

  1. … 1 more file in changeset.
DEN-6372: Added rinseback timeout alarm.

DEN-6372: Added new alarm for too long in treatment re-circ sub-mode.

DEN-6372: Added new stop alarm for after rinseback that will not escalate. Added blood prime treatment sub-mode.

  1. … 2 more files in changeset.
DEN-6372: Added enum for rinseback user actions.

  1. … 2 more files in changeset.
DEN-5887: Added new alarms for load cell acceleration events.

DEN-6200: Added alarm id and prime pause state

  1. … 2 more files in changeset.
DEN-6200: Added alarm id and prime pause state

  1. … 2 more files in changeset.
DEN-6372: Updated rinseback and re-circ sub-modes in enum. Added new rinseback and re-circ message IDs.

  1. … 2 more files in changeset.
DEN-6372: Updated rinseback and re-circulate sub-modes in enum.

  1. … 1 more file in changeset.
DEN-6200: Added prime out of time alarm and command reject reasons

  1. … 2 more files in changeset.
DEN-6200: Added prime out of time alarm and command reject reasons

  1. … 2 more files in changeset.
DEN-6200: Added alarms for pre-treatment

DEN-6200: Added alarms for pre-treatment

DEN-5963 updated the alarm table

DEN-6081 added an alarm for RO pump safety shutdown

DEN-6080 added comments and new alarm IDs

  1. … 1 more file in changeset.
DEN-6081 added another alarm ID for flow rate out of lower range

  1. … 1 more file in changeset.
quick_fix_01

- changed the enum index to 49 to be like the previous so the test won't fail.

quick_fix_01

- During the headless SquishQt test found out that a change on the common repo made the build failed.

- The modification was deletion of ALARM_ID_TEMPERATURE_SENSORS_INCONSISTENT enum item.

It has been reverted back to make the build work with application master branch but checking out to this branch for the use of common codes.

DEN-5674: Added msg ID for auto-ACK to enum. Updated some alarm properties in alarm table.

  1. … 1 more file in changeset.
DEN-5674: Fixed alignment of alarms table header.