dgfirmware

Clone Tools
  • last updated a few seconds ago
Constraints
Constraints: committers
 
Constraints: files
Constraints: dates
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

    • -2
    • +2
    /firmware/App/Controllers/DialysateFlow.c
    • -0
    • +16
    /firmware/App/Controllers/FlowSensors.c
    • -0
    • +16
    /firmware/App/Controllers/FlowSensors.h
  1. … 38 more files in changeset.
DEN-13598: Formering to devlop in wsdg_dev

DEN-13598: Code review updates

DEN-13460 merged staging and resolved merge conflicts

    • -38
    • +45
    /firmware/App/Controllers/LoadCell.c
    • -2
    • +30
    /firmware/App/Modes/OperationModes.c
    • -2
    • +30
    /firmware/App/Services/Reservoirs.c
    • -2
    • +14
    /firmware/App/Services/SystemComm.c
DEN-13460 addressed the code review comments

Bamboo Commit: Updated DGCommon.h with build versions from Bamboo

Fixed merge conflicts.

DEN-13598: Removed test code and comments.

DEN-13598: Removed test code and comments.

DEN-13598: Removed test code and comments.

DEN-13598: Changed DG FPGA timer accuracy check to be time windowed count type alarm.

Bamboo Commit: Updated DGCommon.h with build versions from Bamboo

Merge branch 'DEN-13903-s80-mg-dg-comm-buffer-opti' into develop

DEN-13903: updated comm buffer to 768 bytes.

Bamboo Commit: Updated DGCommon.h with build versions from Bamboo

Merged DEN-13834

    • -11
    • +24
    /firmware/App/Controllers/Heaters.c
    • -144
    • +8
    /firmware/App/Controllers/ROPump.c
    • -2
    • +3
    /firmware/App/Controllers/UVReactors.c
    • -31
    • +59
    /firmware/App/Modes/ModeHeatDisinfect.c
    • -27
    • +21
    /firmware/App/Services/Reservoirs.c
    • -13
    • +6
    /firmware/App/Services/SystemComm.c
DEN-13834 removed alarm 196 and added code to ignore the read value of a temperature sensor that its MSB is a 1

DEN-13768 Addd function header blocks

    • -0
    • +49
    /firmware/App/Modes/ModeHeatDisinfect.c
DEN-13834 removed the DialysateFlow include

Bamboo Commit: Updated DGCommon.h with build versions from Bamboo

Disabled alarm 196 temporarily

DEN-13834 removed all the traces of DialysateFlow driver

    • -290
    • +0
    /firmware/App/Controllers/DialysateFlow.c
    • -61
    • +0
    /firmware/App/Controllers/DialysateFlow.h
    • -5
    • +5
    /firmware/App/Controllers/FlowSensors.c
    • -8
    • +0
    /firmware/App/Controllers/FlowSensors.h
DEN-13834, DEN-13691, DEN-13685, DEN-13064, DEN-9693, DEN-13778, Updated the flow sensors driver by fixing the override functions. Removed the old RO flow functions and anywhere that they were used. Replaced the VRD valve with a reserved space

    • -0
    • +15
    /firmware/App/Controllers/FlowSensors.c
    • -1
    • +2
    /firmware/App/Controllers/FlowSensors.h
    • -4
    • +10
    /firmware/App/Controllers/Heaters.c
    • -129
    • +6
    /firmware/App/Controllers/ROPump.c
    • -2
    • +3
    /firmware/App/Controllers/UVReactors.c
DEN-13598: Add code for RAM error and FPGA clcok speed.

DEN-13598: Add code for RAM error and FPGA clcok speed.

    • -14
    • +0
    /firmware/App/Controllers/Heaters.h
    • -10
    • +0
    /firmware/App/Controllers/LoadCell.h
DEN-13598 updated the code

    • -15
    • +0
    /firmware/App/Controllers/Heaters.h
    • -11
    • +0
    /firmware/App/Controllers/LoadCell.h
DEN-13834 updated the getValveState function to return the state of the valve in enum. Updated the treatment blocking data to be written to NV data. Updated the FlowSensors driver and renamed the dialysate flow messages to flow sensors messages

    • -16
    • +15
    /firmware/App/Controllers/FlowSensors.c
    • -7
    • +14
    /firmware/App/Controllers/Heaters.c
    • -13
    • +48
    /firmware/App/Controllers/Valves.c
    • -28
    • +27
    /firmware/App/Controllers/Valves.h
    • -25
    • +57
    /firmware/App/Modes/ModeChemicalDisinfect.c
    • -31
    • +59
    /firmware/App/Modes/ModeHeatDisinfect.c
    • -27
    • +21
    /firmware/App/Services/Reservoirs.c
DEN-13598: Updates to FPGA clock speed check.

DEN-13768 Feature complete changes to CoolDownHeater and CoolDownROFilter to imporve cool down time.

    • -33
    • +88
    /firmware/App/Modes/ModeHeatDisinfect.c
DEN-13768 DEN-13892 Start helper functions

    • -2
    • +144
    /firmware/App/Modes/ModeHeatDisinfect.c