Modes

Clone Tools
  • last updated a few minutes ago
Constraints
Constraints: committers
 
Constraints: files
Constraints: dates
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 1 more file in changeset.
DEN-15701: handle stop DG command from HD while in standby water sampling states.

  1. … 1 more file in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

DEN-15647 addressed the code review comments

DEN-15610 fixed DG flush to write basic flush complete timestamp in the usage record

Merged DEN-15647

  1. … 1 more file in changeset.
DEN-15647 updated the heat disinfect active cool mode to deenergize the actuators prior to transitioning to cancel water path state

Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 1 more file in changeset.
DEN-15571, DEN-15398 changed the fill mode full speed prime time from 8 seconds to 7 seconds

DEN-15571 addressed the code review comments

DEN-15571 updated the chemical disinfect drain status function

DEN-15571 made changes in the chemical disinfect mode to not trigger the max temeprature and conductivity out of range until the end of the chemical disinfect mode

Merged staging

  1. … 7 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 13 more files in changeset.
DEN-15571 changed the chemical disinfect temperature timeout from 1 minute to 5 minutes

Merge branch 'DEN-15367-hd_dg_test_configuration_setup' into develop

  1. … 4 more files in changeset.
DEN-15367 removed the payload from the message that informs HD that DG is ready to dispense more fluid in DG. DEN-15571 fixed the chemical disinfect state machine to transition to cancel water path once the target temperature was not reached within the specified time

  1. … 1 more file in changeset.
DEN-15367 addressed the code review comments

  1. … 5 more files in changeset.
DEN-15522 fixed the heat disinfect active cool fill timeout not triggering. DEN-14805 fixed chemical disinfect reservoir leak alarm

Merge branch 'DEN-15367-hd_dg_test_configuration_setup' into develop

  1. … 4 more files in changeset.
DEN-15367 changed the RO permeate sample cancel water path. DEN-14004 changed the request message from UI to 0x89. DEN-15509 changed the reservoir threshold from 1700 to 1850 mL. DEN-15192 changed the concentrate pump low speed threshold.

  1. … 2 more files in changeset.
-DEN-15367 fixed the transition to cancel water path in RO permeate sample mode -DEN-14004 changed the request message ID to 0x89 from UI to send the DG service record -DEN-15192 changed the concentrate pumps low speed check threshold -DEN-15509 changed the reservoir full threshold from 1700 mL to 1850 mL.

  1. … 3 more files in changeset.
DEN-14004 added another message to receive and send DG service record upon request from HD. The format of the payload is different from the format that is sent to UI

  1. … 3 more files in changeset.
DEN-15367, DEN-15389, DEN-15511, DEN-15443 added code in the mode fill to check for the conductivity of the values in the produce state and have a timeout. Removed the acid check at the end of the mode fill

  1. … 1 more file in changeset.
DEN-15367, DEN-15404 worked on RO permeate sample mode

  1. … 2 more files in changeset.
DEN-15367, DEN-15404 work in progress. Updated the RO permeate sample mode code to be able to receive and send ready command to HD for further dispensing or canceling the run

  1. … 5 more files in changeset.
DEN-15367 added test configuration to be able to run chemical disinfect without PAA acid

DEN-15367, DEN-15446 renamed the function that checks whether any of the inlet water conditions are active in a cleaning mode

  1. … 2 more files in changeset.
Merged DEN-15367

  1. … 6 more files in changeset.
DEN-15446 added a function to check the status of the inlet water conditions and trigger the cleaning modes to transition to cancel water path

  1. … 2 more files in changeset.