Merge branch 'staging' into DEN-15274-hd_dg_test_configuration_setup

Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

DIAL-251: code review comments.

Merge branch 'staging' into DEN-15196-DIAL-251

DIAL-251: DG changes for operation status event handling.

DEN-15274 updated the GenIdle fill target to 0.8 L/min

DEN-15274 fixed the bad fill target volume

  1. … 1 more file in changeset.
Uncommented code

Merged DEN-15274

  1. … 7 more files in changeset.
DEN-15274 changed the target flow of the GenIdle temporarily

DEN-15274 addressed the code review comments

  1. … 2 more files in changeset.
DEN-15274 addressed the code review comments

  1. … 2 more files in changeset.
DEN-15274, DEN-15246 Added code to not lose the commanded fill volume from HD due to multiple bad fill modes. Updated the heaters code to keep getting the dialysate the flow for the trimmer control. Updated the drain to volume function

  1. … 3 more files in changeset.
Merge branch 'staging' into DEN-15274-hd_dg_test_configuration_setup

DEN-15274 created another function to drain to a target volume in milliliters

  1. … 2 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 4 more files in changeset.
Merged DEN-15246

  1. … 2 more files in changeset.
DEN-15246 updated the bicarb RO flow from 400 mL/min to 800 mL/min

DEN-15246 merged staging

DEN-15246 addressed the code review comments

  1. … 1 more file in changeset.
DEN-15274 work in progress, added a set of commands to be able to get, send, and set the load cells tare values

  1. … 6 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

DEN-15265 addressed a code review comment

DEN-15265 addressed a code review comment

DEN-15265, DEN-15236 changed the chemical disinfect monitor to check the dialysate cap not to be closed in during the disinfect since the PAA acid is connected to it.

Merged DEN-15265

DEN-15265, DEN-15246 changed the heat disinfect's primary target temperature to 60 C prior to filling with water for the actual heat disinfct. Updated the code to properly exit the bad fill state of the gen idle mode once the bad sequence is finished

Merge branch 'DEN-15246-active-reservoir-empty-post-concentrate-alarm-recovery' into develop

  1. … 2 more files in changeset.
DEN-15246 added more code to support different conductivity sensors calibration tables

  1. … 4 more files in changeset.
DEN-15246 changed the bad fill end of state