DEN-14000 Use calculated value for rotor vs motor speed error check.

Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 27 more files in changeset.
DEN-13834 merged staging

  1. … 9 more files in changeset.
DEN-13460 addressed the code review comments

  1. … 2 more files in changeset.
DEN-13903: Changed no air detection from 20 seconds to 40 seconds. Changed upper level air trap alarm to use the correct alarm.

  1. … 1 more file in changeset.
Merge branch 'DEN-13834-dg_hd_dev-hd_dg_dvt-update-part-3' into develop

  1. … 2 more files in changeset.
DEN-13834 changed the service and disinfect alarms to reject reasons. Added retries for the blood leak zero command

  1. … 3 more files in changeset.
Fixed merge conflicts.

  1. … 4 more files in changeset.
Merge branch 'DEN-13903-s80-mg-DIAL-204' into develop

  1. … 6 more files in changeset.
DEN-13903: DIAL-204: Fixes. Linking. Removal of warnings.

  1. … 1 more file in changeset.
DEN-13903: fixed alarm persistence to use correct define

DEN-13903: DIAL-204: Implemented set PWM for all 3 HD pumps.

  1. … 2 more files in changeset.
DEN-13903: Alarm is triggered when the air trap gets to the upper level in treatment for 2s persistence.

Merged DEN-13834

  1. … 4 more files in changeset.
DEN-13903: DIAL-204: Init commit

DEN-13834 updated the code

  1. … 10 more files in changeset.
DEN-13903: Changed Air Trap control to use the lower level sensor for opening and closing instead of the upper.

DEN-13598 updated the code

Merge branch 'DEN-13801-sw_dev-sprint-79_mg' into develop

  1. … 6 more files in changeset.
DEN-13801: DEN-13426: wrapped a new minimum occlusion sensor count behind the V3 SWConfig.

DEN-13598 updated the code

  1. … 3 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 6 more files in changeset.
DEN-13834 updated the blood leak self test status set

  1. … 1 more file in changeset.
DEN-13598 Update code for new SRS with alarms.

  1. … 2 more files in changeset.
Merged DEN-13834

  1. … 8 more files in changeset.
DEN-13834 added the DG heaters broadcast message. Addded a function to check the status of the trimmer heater's state in DGInterface and keep sending the command from HD until the trimmer heater is in the right status. Enabled stop/start trimmer command in the modes

  1. … 4 more files in changeset.
DEN-13460 addressed the code review comments

  1. … 7 more files in changeset.
DEN-13460 merged staging

  1. … 3 more files in changeset.
DEN-13460 updated the drivers

  1. … 2 more files in changeset.
DEN-13460: Adjusted DPi initial PWM estimate per data from Eliza.

  1. … 1 more file in changeset.