Controllers

Clone Tools
  • last updated a few seconds ago
Constraints
Constraints: committers
 
Constraints: files
Constraints: dates
DEN-15347: Addressed issue recovering from venous occlusion alarm 208.

DEN-15306-hd-fault-valve-position-alarm-after-restoring-ac-power-4

Comments.

  1. … 1 more file in changeset.
DEN-15306-hd-fault-valve-position-alarm-after-restoring-ac-power-4

Addressing last few new comments.

  1. … 1 more file in changeset.
Fixed merge conflicts from staging.

  1. … 2 more files in changeset.
DEN-15306-hd-fault-valve-position-alarm-after-restoring-ac-power-4

Comment updates.

DEN-15306-hd-fault-valve-position-alarm-after-restoring-ac-power-4

Reponse to comments.

  1. … 1 more file in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 5 more files in changeset.
Merge branch 'DEN-15317-usability-hd-door-open-alarm-during-post-treatment' into develop

  1. … 2 more files in changeset.
DEN-15317: Fixed issue with failure to populate pressure limit state in the pressure data broadcast msg x9.

DEN-15306-hd-fault-valve-position-alarm-after-restoring-ac-power-4

Clear early initiation of block on cpld signal, HW recovery on release of cpld, SW recovery on alarm clear, normal alarm operation 10 seconds later.

  1. … 4 more files in changeset.
Merge branch 'DEN-15196-DIAL-258' into develop

  1. … 5 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 9 more files in changeset.
Merge branch 'DEN-15359-usability-arterial-and-venous-pressure-alarm-limits' into develop

DEN-15359: Misc fixes to art/ven pressure limit changes.

  1. … 1 more file in changeset.
Merge branch 'DEN-15359-usability-arterial-and-venous-pressure-alarm-limits' into develop

  1. … 1 more file in changeset.
DEN-15359: Fix s/w fault bug. Change so that dialysate flow change will also kick pressure limit s.m. back to stabilization state.

  1. … 1 more file in changeset.
DEN-15306-hd-fault-valve-position-alarm-after-restoring-ac-power

Corrected counter reset conditions.

Added CPLD.h

Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 4 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

Merge branch 'DEN-15396-2-alarm-42-hd-fault-dpo-rotor-encountered-in-blood-prime-dvt-001' into staging

Merge branch 'DEN-15359-usability-arterial-and-venous-pressure-alarm-limits' into develop

  1. … 3 more files in changeset.
Merge branch 'DEN-13865-fw-duplicate-alarms-occur-during-post-treatment-rinseback-and-block-workflow' into develop

DEN-15359: Addressed code review comment.

DEN-15396 Code review comment, use macro.

Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

DEN-15306-hd-fault-valve-position-alarm-after-restoring-ac-power

Made the power loss check uniform

isACPowerLoss is an alarm status, move to AlarmMgmt

Trigger with CPLD power loss flag, recover HW state when AC returns, start alarm block countdown after alarm is cleared.

  1. … 4 more files in changeset.
DEN-15359: handle blood flow rate change in middle of stabilization state.

DEN-15359: broadcast pressure data immediately after window change by user.

DEN-15359: Addressed code review comments.

  1. … 1 more file in changeset.
DEN-15359: finished arterial/venous pressure limits window update.

  1. … 3 more files in changeset.