Controllers

Clone Tools
  • last updated a few minutes ago
Constraints
Constraints: committers
 
Constraints: files
Constraints: dates
DEN-14344: code review fixes.

Merge branch 'DEN-14344-sw-s85-mg-air-pump' into develop

  1. … 2 more files in changeset.
DEN-14344: code review fixes.

  1. … 1 more file in changeset.
DEN-14344: code review comments

Merge branch 'DEN-14344-sw-s85-mg-air-pump' into develop

  1. … 7 more files in changeset.
DEN-14344: compiler fixes

DEN-14344: fixed merge conflict missing lines.

Merge branch 'staging' into DEN-14344-sw-s85-mg-air-pump

  1. … 6 more files in changeset.
DEN-14344: Misc formatting fixes.

Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 16 more files in changeset.
Merge branch 'DEN-14344-sw-s85-mg-air-pump' into develop

  1. … 6 more files in changeset.
DEN-14344: fixes for adjusted venous limits when air pump is on

DEN-14307: partial fix to DEN-14086.

DEN-14344: complier fixes and warnings

  1. … 1 more file in changeset.
DEN-14344: created air pump monitor function for alarm id 316. Created a timer for venous pressure to handle adjusted treatment values for a time while the air pump is operating. Allow HD to start filling after consumable testing in pretreatment instead of waiting after dry self tests. formatted ifndef release code blocks to look neater.

  1. … 1 more file in changeset.
DEN-14007 Code Review comments update 1.

  1. … 1 more file in changeset.
DEN-14344: implmented venous pressure limits to increase when air pump is on. Reworked Air trap logic to turn off after air in the upper sensor for 2 seconds. Changed air pump timeout to be 5s.

DEN-14307 updated the code to get the heat disinfect temperature sensors (THd) and checks it value prior to starting a treatment

  1. … 2 more files in changeset.
DEN-14307: HD rotor vs. motor check - changed RPM threshold from 5 to 2 RPM.

DEN-14344: implementation with of alarm id 316

Merge branch 'DEN-14433-sw-s86-mg-broadcast-fixes' into develop

  1. … 3 more files in changeset.
DEN-14433: DIAL-123: fixed broadcast messages to send if we are >= of their respective intervals instead of >.

  1. … 2 more files in changeset.
Merge branch 'staging' into DEN-14307-dg_hd_dev-hd_dg_dvt-update-part-6

  1. … 4 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 4 more files in changeset.
DEN-14458 addressed the code review comments

  1. … 1 more file in changeset.
Merge branch 'DEN-14307-dg_hd_dev-hd_dg_dvt-update-part-6' into develop

  1. … 4 more files in changeset.
DEN-14007 Update all pump speed checks for proper forward / reverse direction checking.

DEN-14458 updated the air trap's broadcast interval

Merge branch 'DEN-14458-reservoirs-don-t-drain-when-treatment-is-ended-from-pre-treatment' into develop

  1. … 2 more files in changeset.
DEN-14259 added an extra check prior to triggering the dialin, dialout, blood pumps speed alarm