DEN-11114: Fixed issue with DPi start during blood prime.

DEN-11114: Fixed sign issue in HD pump set function.

DEN-11250 Updated the syringe pump empty position

DEN-11114: Added build switch to disable illegal air trap levels state alarm.

  1. … 1 more file in changeset.
DEN-11098 Corrected R1 and R2 in bypass state and dialyzer state

  1. … 1 more file in changeset.
Fixed merge conflicts.

  1. … 2 more files in changeset.
DEN-11114 addressed the code review comments

  1. … 5 more files in changeset.
DEN-11114 updated the reservoirs code

  1. … 3 more files in changeset.
Merge branch 'DEN-11114-dg_dev-dg-dialysate-temperature-control-2-of-2' of ssh://dvm-linux02:7999/hd/hdfirmware into DEN-11114-dg_dev-dg-dialysate-temperature-control-2-of-2

DEN-11114: Prevent pump set command from restarting pump control if rate/mode are not changed.

DEN-11114 tested the modified the reservoir management code

  1. … 3 more files in changeset.
DEN-11114 continued working on the reservoir management

  1. … 3 more files in changeset.
DEN-11114 continued working on the resevoir management

  1. … 7 more files in changeset.
DEN-11114: Removed obsolete UF PI controller. Cleaned up UF control code changes.

  1. … 2 more files in changeset.
DEN-11114: Added comment.

DEN-11114 initial commit of the reservoirs module. Continued with implementing the reservoir management

  1. … 6 more files in changeset.
DEN-11114: Updated UF control to included estimated UF flow as input.

  1. … 2 more files in changeset.
Merge branch 'DEN-11114-dg_dev-dg-dialysate-temperature-control-2-of-2' into develop

DEN-11114: Restored previous motor controller speed feedback conversion to RPM - it was right before.

Merge branch 'DEN-11114-dg_dev-dg-dialysate-temperature-control-2-of-2' into develop

DEN-11114: Fixed conversion issue for pump speed ADC voltage levels.

  1. … 1 more file in changeset.
DEN-11114: Changed syringe ID measurement to median between min and max ID given by manufacturer. Included prime volume in calculation of volume needed to meet needs of treatment.

DEN-11114: Updated syringe inner diameter to improve dispense accuracy. Updated minimum dispense rate to 0.2 mL/hr.

DEN-11114: Add 5 sec persistence to blood leak alarm. Make insufficient Heparin volume alarm pre-emptive during seek operation.

Merge branch 'DEN-11114-dg_dev-dg-dialysate-temperature-control-2-of-2' into develop

DEN-11114: Reset BP rotor count before each treatment starts. Allow BP rotor count override to work even if WORN_CARTRIDGE build flag is enabled.

  1. … 1 more file in changeset.
Disabled watchdog and safety shutdown POST tests for unit 2.

  1. … 4 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 57 more files in changeset.
DEN-9906: Addressed code review feedback.

DEN-9906: Fixed doxygen comments in BloodFlow module.