TreatmentEnd.h

Clone Tools
  • last updated a few minutes ago
Constraints
Constraints: committers
 
Constraints: files
Constraints: dates
RESOLVED IN CODE WALKTHROUGH

RESOLVED IN CODE WALKTHROUGH

Done.

Done.

Add syringePumpStateStartTime to header.

Add syringePumpStateStartTime to header.

HD-DEN-16200_Syringe Pump Stuck IN Priming State
HD-DEN-16200_Syringe Pump Stuck IN Priming State
RESOLVED in CODE WALKTHROUGH.

RESOLVED in CODE WALKTHROUGH.

Removed overrides.

Removed overrides.

Do we need to be able to override broadcast interval for this? I wouldn't think so. But if we do, need Dialin updated to support that.

Do we need to be able to override broadcast interval for this? I wouldn't think so. But if we do, need Dialin updated to support that.

RESOLVED in CODE WALKTHROUGH.

RESOLVED in CODE WALKTHROUGH.

Updated with publish function and overrides.

Updated with publish function and overrides.

We should send this countdown msg from a publish function that gets called by exec function for treatment end only once per second (see how this msg is sent by rinseback mode for example). And shou...

We should send this countdown msg from a publish function that gets called by exec function for treatment end only once per second (see how this msg is sent by rinseback mode for example).
And should send the message all the time. If in the wait for rinseback state, just send zeroes (and UI won't show countdown). If in paused state, always send 300 seconds for timeout and 300-(bloodSittingTimerCtr / 20) for countdown (don't let it go negative or wrap though). If an alarm dialog is being displayed, it should show the countdown for the whole 5 minutes (not just the last minute after warning).

HD-DEN-15664_Blood Pump Stop Time Exceeded Alarms 124 125 165 And 212 Alarm Timer Feature IS
HD-DEN-15664_Blood Pump Stop Time Exceeded Alarms 124 125 165 And 212 Alarm Timer Feature IS
HD-DEN-6372_HD Rinseback
HD-DEN-6372_HD Rinseback
RESOLVED in CODE WALKTHROUGH.

RESOLVED in CODE WALKTHROUGH.

Fixed.

Fixed.

Need to fix doxygen style. @details Inputs: @details Outputs:

Need to fix doxygen style.
@details Inputs:
@details Outputs:

RESOLVED in CODE WALKTHROUGH.

RESOLVED in CODE WALKTHROUGH.

RESOLVED in CODE WALKTHROUGH.

RESOLVED in CODE WALKTHROUGH.

RESOLVED in CODE WALKTHROUGH.

RESOLVED in CODE WALKTHROUGH.

RTCs are sync'd by UI sending its date/time to HD and DG f/w. However, RTC time is not used for treatment time. Treatment time is accumulated using HD timer counter. HD then uses this and set treat...

RTCs are sync'd by UI sending its date/time to HD and DG f/w.
However, RTC time is not used for treatment time. Treatment time is accumulated using HD timer counter. HD then uses this and set treatment duration to calculate time remaining. All are then sent to UI regularly.

Done.

Done.

Aligned.

Aligned.