  1. … 8 more files in changeset.
Fixed comm receive bug.

  1. … 4 more files in changeset.
Added UT for pressure/occlusion module and PI controllers module. Updated UT/IT. Minor fixes per UT/IT.

  1. … 6 more files in changeset.
DEN-431 Added the APIs for Dialin

  1. … 3 more files in changeset.
CAN ACK fixes. Updates to UT for ACKs.

  1. … 2 more files in changeset.
Updated code with latest in master

More fixes to CAN ACK feature. Updates to UT for SystemComm modules.

  1. … 1 more file in changeset.
Minor fixes to CAN ACK.

  1. … 5 more files in changeset.
Added function to pump modules to set the PWM. Minor fixes to CAN ACK feature. Started updated UT/IT for CAN ACK feature.

  1. … 5 more files in changeset.
Added new PresOccl, Dialysis, and TreatmentStop modules. Updated test scripts for system communication modules.

  1. … 16 more files in changeset.
Added new alarm for no CAN ACK on message.

  1. … 3 more files in changeset.
Updated vectorcast testing

  1. … 1 more file in changeset.
Tuned pump control. Fixed PIController anti-windup. Added some temporary debug code. Added feature to CAN for messages that require an ACK.

  1. … 15 more files in changeset.
Updated code to make it work with dialin

  1. … 3 more files in changeset.
Merge branch 'master' into DEN-1312-hd-dialysate-inlet-pump-drive-flow-sensor-control

  1. … 28 more files in changeset.
Update CAN interface to test DialOutFlow module

  1. … 8 more files in changeset.
Updated UT for SystemComm and SystemCommMessages modules.

Removed DialOutFlow module - Leo added to separate branch. Fixed alarm lamp POST.

  1. … 18 more files in changeset.
Updated the Copyright with the current year and replaced tabs with 4 spaces

  1. … 64 more files in changeset.
Added dialin messages for dialysate inlet pump. Fixes to watchdog expired fault. Updates to existing UT.

  1. … 6 more files in changeset.
Updated FPGA registers. Removed some CAN debug code. Removed html reports from vectorcast.

  1. … 2 more files in changeset.
Updated CAN interrupts config. Added a watchdog expired alarm. Added PWM duty cycle to blood flow broadcast.

  1. … 18 more files in changeset.
Added some more CAN debug code. Minor updates to blood and dialysate pump modules.

  1. … 5 more files in changeset.
Added SPI driver for GPIO. Set appropriate motor dir and stop pins for dialysate pump modules. Added calls to init dialysate pump modules. Added exec calls from tasks for dialysate pump modules.

  1. … 10 more files in changeset.
Updated flow filter in BloodFlow per discussion with Blaine. Added ADC channels for dialysate pumps. Added some debug code for CAN tranmit issue. Added GPIO for dialysate pumps to HALCoGen.

  1. … 19 more files in changeset.
Added bloodflow overrides for not yet implemented sensors. Condensed published alarms status message.

  1. … 6 more files in changeset.
Fixed code review issue. +review HD-DEN-759-1

Fixed white space between brackets throughout. Added some debug code to help troubleshoot comm issue. Updated power off messaging. +review HD-DEN-759-1

  1. … 84 more files in changeset.
Addressed code review feedback. Fixed an intermittent CAN bug. Updated UT for Buttons, CPLD, and Interrupts modules. +review HD-DEN-759-1

  1. … 11 more files in changeset.
Added UT start for AlarmMgmt module. Finished implementing power off timeout. Added new check-in messages for DG and UI to let HD know it is still communicating. Added delay in bulk of HD powerup until UI starts communicating on CAN to prevent CAN bus error. Added PI control to flow for blood pump. +review HD-DEN-759-1

  1. … 15 more files in changeset.