LDT-94: Added basic treatment mode, dialysis state, treatment parameters mode. Added skeletal treatment paused state.

  1. … 25 more files in changeset.
LEAH-60: Addressed code review comments.

  1. … 5 more files in changeset.
LEAH-60: Calculate TMP from venous pressure and post-dialyzer dialysate pressure.

  1. … 1 more file in changeset.
LEAH-60: Updates for treatment related interfacing between TD and UI/DD.

  1. … 6 more files in changeset.
LEAH-838: Addressed code review feedback.

  1. … 17 more files in changeset.
LEAH-1970: Addressed code review comments.

TEST: refactor component names.

  1. … 15 more files in changeset.
TEST: refactor of component names.

  1. … 15 more files in changeset.
LEAH1970: Refactored component codes to new style of codes for consistency.

  1. … 23 more files in changeset.
TEST: refactor component codes to new codes for consistency.

  1. … 23 more files in changeset.
TEST: changes during alpha prototype integration.

  1. … 14 more files in changeset.
TEST: Misc fixes and testing accomodations.

  1. … 3 more files in changeset.
LEAH-39: cosmetic fixes.

LEAH-47: Addressed code review feedback.

  1. … 2 more files in changeset.
LEAH-47: Call pressure monitor from main.

  1. … 2 more files in changeset.
LEAH-47: Added pressure monitor unit.

  1. … 3 more files in changeset.
LEAH-47: Misc fixes.

  1. … 5 more files in changeset.
LEAH-47: Added driver and controller for air pump. Added buttons monitor. Added switches monitor. Used new override message helper functions.

  1. … 22 more files in changeset.
Added Dialin support to bubble and voltage monitors. Addressed code review comments.

  1. … 5 more files in changeset.
LEAH-41: Added bubble monitor unit. Added bubble interval override.

  1. … 5 more files in changeset.
LEAH-41: Updated Dialin overrides for voltages monitor unit.

  1. … 1 more file in changeset.
LEAH-41: Updated internal ADC channels per schematic. Added voltages monitor.

  1. … 7 more files in changeset.
Added read and error count check for pressure sensor driver. Touched all units for code review purposes.

  1. … 48 more files in changeset.
Updated function headers.

  1. … 45 more files in changeset.
Started message enum from scratch.

  1. … 7 more files in changeset.
Started alarm table from scratch. Started s/w fault table from scratch.

  1. … 16 more files in changeset.
Initial foundation based on code from Denali HD. AlarmMgmt, SystemComm and FPGA are split with common parts going to a fwcommon unit and reset going to sub-sys specific unit. WatchdogMgmt moved to fwcommon.