Changed the heat disinfect control

  1. … 1 more file in changeset.
Merge branch 'DEN-13460-dg_hd_dev-hd_dg_dvt-update-part-2' into develop

  1. … 7 more files in changeset.
DEN-13460 updated the code

  1. … 9 more files in changeset.
Merged DEN-13460

  1. … 3 more files in changeset.
DEN-13460 updated the concentrate pump speed check and the increased the heaters on with no flow to 10 seconds

  1. … 4 more files in changeset.
Merge remote-tracking branch 'origin/develop' into develop

Merge branch 'DEN-12974-miscellaneous-flush-issues_bb' into develop

DEN-12974 DEN-13558 Update to fill status functions to support V&V

Merged DEN-13460

  1. … 9 more files in changeset.
DEN-13460 updated the fault mode to be able to read the NV records in case it was not read correctly

  1. … 1 more file in changeset.
DEN-13460 updated the drivers with the DVT features

  1. … 13 more files in changeset.
Merge branch 'DEN-13427-sw_dev-sprint-75_mg' into develop

  1. … 22 more files in changeset.
Merge branch 'staging' into DEN-13427-sw_dev-sprint-75_mg

  1. … 6 more files in changeset.
DEN-13460 merged staging

  1. … 19 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 26 more files in changeset.
DEN-12931 addressed the code review comments

  1. … 4 more files in changeset.
DEN-12931 addressed the code review comments

  1. … 10 more files in changeset.
DEN-12974 DEN 13558 Prototype new timer design for drain pump and reservoir status

Merge branch 'DEN-13460-dg_hd_dev-hd_dg_dvt-update-part-2' of ssh://dvm-linux02:7999/dg/dgfirmware into DEN-13460-dg_hd_dev-hd_dg_dvt-update-part-2

DEN-13460 Set Clean LED colors for each mode entry.

DEN-12974 DEN 13558 Prototype new timer design for drain pump and reservoir status

DEN-13460: Fixed 2 broadcast interval bugs.

  1. … 1 more file in changeset.
DEN-13427: DG Service Mode deenergizes and can Fault

Service Mode deenergizes actuators when we enter the mode. Fault is raised in Service Mode if we get a submode out of range.

  1. … 1 more file in changeset.
Merge branch 'DEN-13460-dg_hd_dev-hd_dg_dvt-update-part-2' of ssh://dvm-linux02:7999/dg/dgfirmware into DEN-13460-dg_hd_dev-hd_dg_dvt-update-part-2

DEN-13460: Reset bad fill state in gen idle mode when detecting bad fill in case 2 bad fills back to back edge case.

  1. … 1 more file in changeset.
DEN-12974 DEN-13556 Correct logic per SRSDG 333.

DEN12974 DEN-13558 Do not reset stateTimer in FlushR2AndDrainR1. Same issue will be in ModeChemicalDisinfect.

DEN-12974 DEN-13560 Do not reset stateTimer in FlushR1AndR2.

DEN-13460 updated the heaters with the latest primary heater gain check

  1. … 4 more files in changeset.
DEN-13047 haveDrainParmsBeenInit now any array with one entry for each reservoir. DEN-13534 rsrvrFillStableTimeCounter now an array with one entry for each reservoir. May be causing intermittent functionality (test_dg_flush_R1_to_R2_state_R2_filled_before_R1). DEN-12974, DEN-13425 Restore logic around resetting state timer for getRsrvrFillStatus.