DEN-12836: Treatment Report/log export modifications

- DEN-12944: KBM: Usual Meetings/Support/Development

- Modified the setup.sh script to work on PDT (Pacific timezone)

- Added timezone display on the screen by adding it to the VDateTime

- Removed unnecessary FileHandler header include.

- Modified the Treatment Review Export button to export the current TxReport only.

- Added the Safe Eject button for the Post-Treatment TxReport Export.

- Moved Log Folder definitions to the StorageGlobal.

- Fixed the greeting issue [https://github.com/Diality/testsuites/issues/57]

- DEN-11826: Bluetooth BloodPressure Cuff Interval - Observation

- It has completely redesigned

- DEN-9706: Blood Pressure measurement entry window closes automatically

- Auto Hide is disabled

    • -17
    • +7
    ./hd/adjustment/common/VCommonAdjustmentVitals.h
  1. … 20 more files in changeset.
DEN-12558: HD does not transition to service mode

- implemented the service mode confirmation

- decreased the dialog animation duration

- renamed the service dates MVC to differentiate with service mode.

    • -0
    • +57
    ./settings/VAdjustmentServiceDates.cpp
    • -0
    • +77
    ./settings/VAdjustmentServiceDates.h
    • -0
    • +38
    ./settings/VAdjustmentServiceMode.cpp
    • -0
    • +58
    ./settings/VAdjustmentServiceMode.h
  1. … 26 more files in changeset.
wrapping up multiple sprint codes

- LOG: Added a CLI option to disable the Check-In logs by adding -k, --disable-check-in-log at the CLI. This was interrupting the log tests. The build macro has been removed.

- POST: During the coverage find out that the getter functions have not even been called in the ApplicationPost.

- CloudSync: Added the Treatment Code(TxCode), received from the cloud after the Treatment Report stored by Cloud System. It is a message communication between UI<=(2008)=CS.

- CloudSync: Two error added for the 2008: TxCode

- CloudSync: Due to some issues on Cloud System regarding the credential expiration, It has been asked to add a temporary workaround to send the credentials (1004) before message 1006:Device State, 1007:Treatment Report.

- DEN-12727: Treatment Parameter Screen: Added more space between the parameters components specially the Temperature slider and the option on top.

- DEN-12829: Enabled the back button on the Start Treatment Screen

- DEN-12761: Enabled an empty Patient ID.

It has not yet been implemented on the CloudSync App, so if sent empty CloudSystem will later reject to store the TxReport.

When later implemented an unassigned random Patient ID will be created for that TxReport to be later defined and assigned.

- DEN-12837, DEN-12840: The Disinfection Scheduling Entry and the Confirm button have been removed from the "Dialysate Generator Settings" screen.

- DEN-12837, DEN-12840: The "Dialysate Generator Settings" changed to "DG Cleaning" for the menu option and the screen title.

- Settings: The Clear Alarm Condition button has been removed from the settings screen for the release.

- Settings: The options which has no implementation for the phase 1 have been removed from the Settings screen Service mode options. [Language, Calibration, SW Update, Factory Reset]

- DEN-12841: Reworded the password entries in Service screen and for WiFi Join Screen.

- TxCode, TxReport: removed the commented out Treatment Report Parameters from the code.

- LOG: added one character space int he DEBUG log for the Not Enough Data in Types.

- Settings: The Service Dates default values changed from 0 to "" since they are strings.

- Settings: Added some clarification for the Home screen greetings

  1. … 27 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 145 more files in changeset.
RESOLVED.

RESOLVED.

RESOLVED.

RESOLVED.

I don't usually remove these kinds of comments they are there for developers as a reminder to keep the indices match. This is like a code comment.

I don't usually remove these kinds of comments they are there for developers as a reminder to keep the indices match.
This is like a code comment.

So then when would we remove this line of code?

So then when would we remove this line of code?

RESOLVED.

RESOLVED.

Disabled the "coco end"s as well.

Disabled the "coco end"s as well.

DEN-12597 Code Review

http://dvm-linux02:8060/cru/UI-DEN-12258-1#c12773

Disabled the coco end as well, which caused the coco to log a lot of warnings.

    • -1
    • +1
    ./hd/adjustment/common/VCommonAdjustmentVitals.h
  1. … 66 more files in changeset.
To make sure it is intentional, and we didn't miss a parameter. also it helps with the copy pasts later.

To make sure it is intentional, and we didn't miss a parameter.
also it helps with the copy pasts later.

IT has been recently removed from the diagnostics screen. I'm not sure when it will be needed to get back again on that screen. Probably keeping it is a lot easier than reimplementing it.

IT has been recently removed from the diagnostics screen.
I'm not sure when it will be needed to get back again on that screen.
Probably keeping it is a lot easier than reimplementing it.

When will this get fixed (removed)?

When will this get fixed (removed)?

Why only comment out? Can't we just remove?

Why only comment out? Can't we just remove?

very good point Sean. Coco ignores it but logs each one which I think it more bothers us than coco. I am going to disable them too.

very good point Sean.
Coco ignores it but logs each one which I think it more bothers us than coco.
I am going to disable them too.

DEN-12515: KBM: Usual Meetings/Support/Development [ CS/UI Integration on device , Tx Log ]

- implemented the TxLog change request during the meeting.

- Also updated the state changes in the FW.

  1. … 6 more files in changeset.
Does it bother CoCo if you disable a begin but leave the end there?

Does it bother CoCo if you disable a begin but leave the end there?

DEN-12515: KBM: TxLog implementation

- implemented the message 1007 for TxLog to be sent to the CS on HD TxLog received message.

  1. … 4 more files in changeset.
DEN-12512: INT: Support/Meetings/Planning

DEN-09712 Date format between system date/time and BP/HP "Last Read" is not consistent

DEN-09929 Treatment Log shows "?C" instead of "°C"

PRS-35: Regarding Sean's point about the create treatment parameters, made the parameters dynamic by the Configurations/DataList.cfg in ui.config repository.

    • -3
    • +0
    ./hd/adjustment/common/VCommonAdjustmentVitals.h
  1. … 12 more files in changeset.
UI-DEN-12258_UI BN S66
UI-DEN-12258_UI BN S66
DEN-12514: LTS: Support/Development

========== DevTest

- Fixed the reported bugs from the LTTS team:

+ https://github.com/Diality/testsuites/issues/38: Rejection messages are not displayed for heparin under main-treatment screen 38

+ https://github.com/Diality/testsuites/issues/37: "Self Test Complete!" message is not displayed when "DRY_SELF_TESTS_COMPLETE_STATE" is simulated #37

+ https://github.com/Diality/testsuites/issues/36: Indicators are not displayed for 'Wet Self tests" when "HD_PRIME_WET_SELF_TESTS_STATE" is simulated #36

========== CloudSync

- Changed the order of the device registration request and the device info send, in the order above.

========== Internal

- removed the emoji and language globe buttons from the second keyboard layout.

  1. … 7 more files in changeset.
DEN-12427: KBM: Usual Meetings/Support/Development

- The UI will only send the 1006 (latest device state update) if only the state changes.

- Duplicate state updates will not log as an error and will only be ignore.

- The UI will always response back to 2006 (device state request) from CS with 1006 (latest device state) even if the state is the same as the last updated/requested.

  1. … 7 more files in changeset.
DEN-12426: LTS: Bug / CR / Develop Coco / Manual

- removed the "// coco begin validated" to disable the manually validated coverage.

    • -1
    • +1
    ./hd/adjustment/common/VCommonAdjustmentVitals.h
  1. … 67 more files in changeset.
DEN-11812 UI Keyboard displays text on the spacebar and has a wink emoji button

- added the keyboard layout and style to remove some buttons and remove the text on the spacebar.

- added DEBUG_DISABLE_MAXIMIZE, due to touch screen issue on some devices, the maximized alarm can't be minimized to see the screen underneath.

- While fixing some issues in the Dialin/Simulator, added the reject reason notification to the Treatment review screen and cleared the values on rejection.

- update the Dialysate Temperature max to the 37 from 38.

  1. … 39 more files in changeset.
DEN-12262: INT: Support and debugging

- updated/tested the alarmMapping with new changes.

- added the staging to the alamMapping.sh call to checkout always on staging as the mainsteam.

  1. … 2 more files in changeset.
DEN-12262: INT: Support and debugging

- Fixing the DG Valves/Temperature messages

- Fixing the CloudSync RegisterDeviceRequest

- Fixed/Cherry-Picked the Dialin-log conditions.

- Cleaned up the debug messages.

    • -26
    • +26
    ./dg/data/VDGValvesStatesData.cpp
  1. … 15 more files in changeset.