DEN-14607, DEN-13999 updated the fill mode the not command the VPo valve to fill state upon exiting the pause state. Updated the pressures driver to assume the overidden pressure is absolute and not add the baro pressure to make it absolute

  1. … 2 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 22 more files in changeset.
Merge branch 'staging' into DEN-14559-dg_hd_dev-hd_dg_dvt-update-part-8

  1. … 4 more files in changeset.
DEN-14559 updated the code to be able request POST by the Dialin user. Updated the chemical disinfect flush to be able drain the reservoirs all the time

  1. … 10 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 9 more files in changeset.
DEN-13946 Corrections per code review

  1. … 6 more files in changeset.
DEN-13946 Make monitor functions for pressure, temperature, thermistors and load cells consistent. Address code review comments.

  1. … 3 more files in changeset.
DEN-14559 added functions to reset the POST states of the drivers that have a POST state machine for the command to request POST again

  1. … 12 more files in changeset.
Merge branch 'staging' into DEN-13946-certain-temperature-sensors-trigger-wrong-alarm

  1. … 1 more file in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 23 more files in changeset.
Merge branch 'staging' into DEN-14497-dg_hd_dev-hd_dg_dvt-update-part-7

  1. … 23 more files in changeset.
Fixed merge conflicts.

  1. … 22 more files in changeset.
DEN-14497 updated the drain pump flow control algorithm. Fixed the inlet water pressure, temperature, conductivity alarm recovery in treatment modes. Updated chemical disinfect flush mode

  1. … 10 more files in changeset.
DEN-13946 Use typedefs for itterating over sensors.

  1. … 3 more files in changeset.
DEN-13946 - Correct monitor functions where multiple sensors are "or'd" into a single alarm.

  1. … 2 more files in changeset.
DEN-14497 updated the drain pump control for the flow and updating chemical disinfect is in progress

  1. … 5 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 98 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 26 more files in changeset.
Merged staging

  1. … 16 more files in changeset.
DEN-14307 fixed the concentrate pumps' park command ID and addressed the code review comments. Updated heat disinfect mix drain states with the proper actuators

  1. … 12 more files in changeset.
DEN-14307 updated the cleaning modes per the SRS changes

  1. … 10 more files in changeset.
Merged DEN-14253

  1. … 10 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

DEN-14356 addressed the code review comment

DEN-14536 updated the minimum acceptable inlet pressure

DEN-14307 updated the code and updated the checkAlarms.sh to check the alarms manual table upon compilation

  1. … 5 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 22 more files in changeset.
DEN-14175 addressed the code review comments and replaced the V3 enable software configuration flag with the hardware configuration flag from FGPA. Updated the trimmer heater's ramp state to check the use previous duty cycle flag instead of estimating the duty cycle.

  1. … 16 more files in changeset.
DEN-14175, DEN-13999 uncommented DG pressure sensors alarm

DEN-14175, DEN-13999 updated the pressure sensors persitent alarm. Added hardware configuration functions to check the status of the device (i.e. BETA, DVT)

  1. … 5 more files in changeset.