DEN-6200: Added dialyzer and bypass fluid path priming

DEN-5674: Make all code comments start with a capital letter for consistency.

    • -22
    • +22
    /firmware/App/Controllers/BloodFlow.c
    • -22
    • +22
    /firmware/App/Controllers/Buttons.c
    • -10
    • +10
    /firmware/App/Controllers/DGInterface.c
    • -2
    • +2
    /firmware/App/Controllers/DGInterface.h
    • -104
    • +104
    /firmware/App/Controllers/DialInFlow.c
    • -55
    • +55
    /firmware/App/Controllers/DialOutFlow.c
    • -20
    • +20
    /firmware/App/Controllers/PresOccl.c
    • -1
    • +1
    /firmware/App/Drivers/SafetyShutdown.c
  1. … 42 more files in changeset.
DEN-5674: Addressed code review comments.

    • -28
    • +28
    /firmware/App/Controllers/AirTrap.c
    • -126
    • +126
    /firmware/App/Controllers/BloodFlow.c
    • -5
    • +5
    /firmware/App/Controllers/DGInterface.c
    • -19
    • +19
    /firmware/App/Controllers/DialInFlow.c
    • -15
    • +15
    /firmware/App/Controllers/DialOutFlow.c
    • -11
    • +11
    /firmware/App/Controllers/PresOccl.c
    • -1
    • +1
    /firmware/App/Drivers/SafetyShutdown.c
  1. … 13 more files in changeset.
DEN-6200: Home valves in pre-treatment no cartridge self-test

DEN-5381: Increase purge air time out to 30 seconds

DEN-5674: Added msg ID for auto-ACK to enum. Misc. comments. Removed dead code.

DEN-5674: Changed size of alarm silence cmd from U08 to U32 for consistency.

DEN-5381: Added transition to prime and removed ui workflow build switch

DEN-5381: Wait for blood pump finished homing before transition to prime

DEN-5381: Reset pre-treatment state machine and deleted unused code

DEN-5381: Moved DG start and valves homing into pre-treatment mode

DEN-5674: Fixed alarm audio volume control per HDD change.

DEN-5831: Removed eval board and unused includes

DEN-5381: Moved new alarms to available slots

DEN-5381: Increased filling volume to 1700 mL

DEN-5381: Updated hd to dg drain cmd

    • -6
    • +11
    /firmware/App/Controllers/DGInterface.c
    • -1
    • +8
    /firmware/App/Controllers/DGInterface.h
DEN-5381: Removed reservoir drain and fill from standby mode

DEN-5674: Pass valves check when disable valves build switch is on.

DEN-5674: Added handling for resume after alarm. Removed obsolete build switches.

    • -7
    • +2
    /firmware/App/Controllers/DialInFlow.c
    • -7
    • +2
    /firmware/App/Controllers/DialOutFlow.c
    • -20
    • +1
    /firmware/App/Modes/ModePostTreat.c
    • -29
    • +4
    /firmware/App/Modes/ModeTreatment.c
    • -21
    • +0
    /firmware/App/Modes/ModeTreatmentParams.c
  1. … 5 more files in changeset.
DEN-5674: Fix alarm state bug.

DEN-5674: Added alarm silence handling.

DEN-5674: Moved alarm lamp self test from early to later in sequence.

DEN-5674: temporary set alarm volume low for testing.

DEN-5674: Fixed alarms state update.

DEN-5674: Prevent resume/rinseback options if top alarm condition not yet cleared.

DEN-5381: Added reservoir management to prime sub-mode

DEN-5674: Completed UF volume setting pre-treatment.

    • -2
    • +18
    /firmware/App/Modes/ModeTreatmentParams.c
DEN-5674: Removed obsolete test code. Added new UF param msg handler.

    • -1
    • +1
    /firmware/App/Controllers/DialInFlow.c
    • -1
    • +1
    /firmware/App/Controllers/DialOutFlow.c
    • -0
    • +14
    /firmware/App/Modes/ModeTreatmentParams.c
    • -3
    • +5
    /firmware/App/Modes/ModeTreatmentParams.h
  1. … 3 more files in changeset.
DEN-5381: Refactor alarm management module

    • -170
    • +27
    /firmware/App/Services/AlarmMgmt.c
DEN-5381: Added time out for purge air state