LDT-2269 Patient Vitals - SW - 01 - R&I - 05: DEV - Feature Implementation

Initial upload of patient vitals

  1. … 31 more files in changeset.
LDT-931: Main Treatment Screen - SW - Diagnostics Screen-FP - 05: DEV - Feature Implementation

- Add FP Folder structure

- Add The following FP message implementation

Versions

Pressure

Flow

Conductivity

Temperature

Valves

ROPump

BoostPump

Level

-Add FP can channel to Can interpreter

-Implement FP diagnostics screen

  1. … 49 more files in changeset.
LDT-912: Main Treatment Screen - SW - Diagnostics Screen-DD - 05: DEV - Feature Implementation - Adjust DD Valves payload length - Implement Model and View format for DD Valves - Add DD Valves Enum to Gui Globals - Add DD Valves to Diagnostics Screen

  1. … 7 more files in changeset.
LDT-912: Main Treatment Screen - SW - Diagnostics Screen-DD - 05: DEV - Feature Implementation

- implement TD air pump and air bubbles message

- Adjust page indicators in diagnostics screen

- Add TD air pump and bubbles message to diagnostics screen

- fix DD diagnostics conductivity to have fixed float points

-Fix dd dialysate pump model comments

- Add Base of DD valves in doxygen comment TODO LATER

- Address imports for diagnostics QML files

- Generate png files for all SDD items

  1. … 29 more files in changeset.
LDT-912: Main Treatment Screen - SW - Diagnostics Screen-DD - 05: DEV - Feature Implementation

- Move DG Valves to DD and rename to DD

- Implement the following DD messages:

Dialysate Pump, Concentrate pump

- Cleanup Saloine bolus enum in VTDTretamentSattesData.cpp

- Minor comment cleanup in MDDTemperatures

  1. … 27 more files in changeset.
LDT-912: Main Treatment Screen - SW - Diagnostics Screen-DD - 05: DEV - Feature Implementation

-Add SDD for diagnostics screen

- Fix typo in DD Gen dialysate to be 'SpentPressure' instead of 'SpendPressure'

- Move Leahi implementation of DG to now DD folder

- implement DD diagnostics including the following:

Heaters

Pressures

Temperatures

- The following DD message ID's have been updated:

Pressure

Temperature

Heaters

Blood Leak

Dialysate Pump

Concentrate Pump

Valves

  1. … 48 more files in changeset.
Merge branch 'feature/LDT-1209-main-treatment-screen' into staging

  1. … 7 more files in changeset.
Merge branch 'LDT-907-Main-Treatment-Screen-SW-Diagnostics-Screen-DD' into staging

  1. … 10 more files in changeset.
LDT-912: Main Treatment Screen - SW - Diagnostics Screen-DD - 05: DEV - Feature Implementation

- Address Diagnostic QML object names

- Remove all unimplemented DD instances, leaving only DDlevel message

- MModel alignment

  1. … 5 more files in changeset.
LDT-912: Main Treatment Screen - SW - Diagnostics Screen-DD - 05: DEV - Feature Implementation

- Add DD level sensor message

- Add diagnostics QML patch

- Add DD diagnostics base implementation

  1. … 14 more files in changeset.
Merge branch 'LDT-907-Main-Treatment-Screen-SW-Diagnostics-Screen-DD' into develop

  1. … 5 more files in changeset.
LDT-1209 Main Treatment Screen - SW - 01 - Screen Integration (MSG,QML) - R&I - 05: DEV - Feature Implementation

add in treatment time "treatment complete" text to timer and address CR comments

  1. … 21 more files in changeset.
Merge branch 'LDT-627-Main-Treatment-Screen-SW-Messaging-Broadcast' into staging

  1. … 2 more files in changeset.
LDT-912: Main Treatment Screen - SW - Diagnostics Screen-DD - 05: DEV - Feature Implementation

- Make Change for Diagnostic multiple screens

- Add DD Messages definition (messageglobals/messageinterpreter/guiglobals)

  1. … 10 more files in changeset.
LDT-958: Main Treatment Screen - SW - 01 - Auto Message Generation - Integration - R&I - 05: DEV - Feature Implementation

- Removed model and view files

- Tested the auto generated code and compiled the code

  1. … 61 more files in changeset.
Merge branch 'LDT-627-Main-Treatment-Screen-SW-Messaging-Broadcast' into develop

  1. … 2 more files in changeset.
LDT-627: Main Treatment Screen - SW - Messaging Broadcast - 05: DEV - Feature Implementation

- Move Views DD conductivity and Gen dialysate to DD folder

- Align text per CR comments

- Adjust settings information tab for TD and DD serial/Versions

  1. … 6 more files in changeset.
Merge branch 'feature/LDT-450-TreatmentParametersCreateRx' into develop

LDT-627: Main Treatment Screen - SW - Messaging Broadcast - 05: DEV - Feature Implementation - Adjust DD implementation for Conductivity and Gen dialysate mode data due to payload changes

  1. … 7 more files in changeset.
Merge branch 'feature/LDT-450-TreatmentParametersCreateRx' into staging

LDT-455 Treatment Parameters (Create Rx) - SW - 05: DEV - Feature Implementation

- Fixed the issue with the validation message length.

- Fixed the forgotten requirement for the Heparin Stop time less than the Treatment Duration.

- Fixed the issue with the CreateRx branch build issue on the version enums/ddSerial being different than the rest.

  1. … 6 more files in changeset.
Main Treatment Screen - SW - Messaging Broadcast - 05: DEV - Feature Implementation

- Implement TX messages: blood flow, conductivity, saline, UF, tx time, tx set point data, gen Dialysate, pressure

- remove blood pump duplicate and replace with blood flow

  1. … 48 more files in changeset.
Main Treatment Screen - SW - Messaging Broadcast - 05: DEV - Feature Implementation

- Add all main treatment messages: Blood flow, Ultrafiltration, Saline, DD Cond, Gen Dialysate, pressure

- Remove bloodpump model to use bloodflow instead

- Fix diagnostic bug for bloodflow to correct labeling order

-

  1. … 48 more files in changeset.
Merge branch 'feature/LDT-450-TreatmentParametersCreateRx' into staging

  1. … 13 more files in changeset.
Merge branch 'feature/LDT-450-TreatmentParametersCreateRx' into develop

  1. … 13 more files in changeset.
Merge branch 'feature/LDT-450-TreatmentParametersCreateRx' into develop

  1. … 2 more files in changeset.
LDT-455 Treatment Parameters (Create Rx) - SW - 05: DEV - Feature Implementation

- updated the settings device registration to match the td,dd.

- updated the regex for the patient ID to match the extra characters accepted in the Whitney.

- fix the unmatched version messages enums with the changes on the diagnosticsScreen branch

  1. … 3 more files in changeset.
Merge branch 'feature/LDT-450-TreatmentParametersCreateRx' into develop

  1. … 13 more files in changeset.
LDT-455 Treatment Parameters (Create Rx) - SW - 05: DEV - Feature Implementation

- Updated the version message length

- Improved the unhandled messages function performance.

- Updated the Alarm Messages IDs

- Removed the orange Prescription profiel ID with number from the Treatment Confirm Screen table title .

- Added gradient to the MainMenu component.

- Set the main menu height (notificationHeight) higher to the 100.

- Figured that the keyboard may cover the AlarmBar so changged the Keyboard style to remove the bottom margin and made the extra black ribbon not visible when alarmbar is visible to uncover the alarmbar.

- Created a temporary StatusBar/HeaderBar to have a base to adjust other screens.

- Adjusted the Patient ID screen for the new screen size ena keyboard loaction.

- Updated the Virtual Keyboard style to adjust for the new screen size and the AlarmBar.

- Updated the TreatmentRanges for Leahi to read from the settings//configurations.

- Added separate date and time properties in the VDateTime to temporarily display on the StatusBar/HeaderBar.

  1. … 23 more files in changeset.
Main Treatment Screen - SW - Diagnostics Screen - 05: DEV - Feature Implementation

- Fix typos from HD/DG to TD/DD