LEAHI-DD-FIRMWARE-LDT-4733

fixed. thanks!

fixed. thanks!

fixed. thanks!

fixed. thanks!

fixed. thanks!

fixed. thanks!

fixed. thanks!

fixed. thanks!

fixed. thanks!

fixed. thanks!

this would be out of scope of the original ticket. https://diality.atlassian.net/browse/LDT-4733 Looking at the debug data, this alarm would still trigger. Voltage values are still reporting 0.

this would be out of scope of the original ticket. https://diality.atlassian.net/browse/LDT-4733

Looking at the debug data, this alarm would still trigger. Voltage values are still reporting 0.

Did you get a chance to test this alarm and uncomment the code?

Did you get a chance to test this alarm and uncomment the code?

Remove empty space.

Remove empty space.

ACToDC?

ACToDC?

Count datatype seems to be integer. Type case to F32 to match with denominator data type.

Count datatype seems to be integer. Type case to F32 to match with denominator data type.

Align comment. Clarify (at least in comments) that these macros are for FPGA count conversions.

Align comment.
Clarify (at least in comments) that these macros are for FPGA count conversions.

Remove extra blank lines.

Remove extra blank lines.

LEAHI-DD-FIRMWARE-LDT-4733_(Request) Add variables to capture AC/DC heater electrical data
LEAHI-DD-FIRMWARE-LDT-4733_(Request) Add variables to capture AC/DC heater electrical data