GuiGlobals.cpp

Clone Tools
  • last updated a few minutes ago
Constraints
Constraints: committers
 
Constraints: files
Constraints: dates
DEN-12558: HD does not transition to service mode

- implemented the service mode confirmation

- decreased the dialog animation duration

- renamed the service dates MVC to differentiate with service mode.

  1. … 32 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 159 more files in changeset.
DEN-12597 Code Review

http://dvm-linux02:8060/cru/UI-DEN-12258-1#c12773

Disabled the coco end as well, which caused the coco to log a lot of warnings.

  1. … 80 more files in changeset.
DEN-12426: LTS: Bug / CR / Develop Coco / Manual

- removed the "// coco begin validated" to disable the manually validated coverage.

  1. … 81 more files in changeset.
DEN-11812 UI Keyboard displays text on the spacebar and has a wink emoji button

- added the keyboard layout and style to remove some buttons and remove the text on the spacebar.

- added DEBUG_DISABLE_MAXIMIZE, due to touch screen issue on some devices, the maximized alarm can't be minimized to see the screen underneath.

- While fixing some issues in the Dialin/Simulator, added the reject reason notification to the Treatment review screen and cleared the values on rejection.

- update the Dialysate Temperature max to the 37 from 38.

  1. … 40 more files in changeset.
DEN-12262: INT: FW Support (Reset Diagnostic Data)

  1. … 11 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 77 more files in changeset.
DEN-12121: Implemented QML updates, proper view links for QML, and remaining implementation for new messages to the QML stack. All relate to DEN-12118.

  1. … 14 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 584 more files in changeset.
DEN-9968: GUI does not indicate the amount of time the device has been stopped in pre-treatment & treatment

- Added message ID_TreatmentStop = 0x4900, // 73 and its Model, View

- Added a timer on the Alarm Dialog which is visible in Treatment Stop and if the message above has a total value.

  1. … 14 more files in changeset.
[ DEN-9653 , DEN9655 ] : Implementation - Settings [ Screen , MVC ]

  1. … 17 more files in changeset.
DEN-9416: Implementation

DEN-9299: Adding the Syringe Pump data on Diagnostic

  1. … 24 more files in changeset.
DEN-9416: Implementations

- Most of the FW implementation is done.

- After the Check-in message two more messages needs to be sent to the HD to complete the POST:

- Version for the compatibility test.

- UI_POST to wrap the POST on HD side.

  1. … 14 more files in changeset.
DEN-8920 Implementation [Store Collected Data]

- Added MVC

- Added the TxLog and Log_Events and so...

- Added the timeout/interval

- ....

  1. … 14 more files in changeset.
DEN-8910: Meetings & Support - General Support

- Active Alarm List toggle while the minimize is disables.

- Wrapped up the Serial information in settings

- Wrapped up the Service information in settings

- Fixed a minor issue in logging threading which was adding the log header in main thread and added more threading check for Logger.

- Added Screenshot functionality to the application by F12 on keyboard to save on usb drive "screenshot" folder with <yyyyMMdd-HHmmss>.png file format on device and on Desktop/Screenshot on desktop version.

  1. … 50 more files in changeset.
DEN-8693: Support for the disinfect

- Adding support for reading the brightness value from the Linux file system instead of having another file just to keep the same value.

- Fixed a bug in the Active Alarm List request.

- Adding the functionality of the Alarm Volume.

- Modified the Disinfection screens[Heat/chem] check marks with the new bundled states provided by FW for UI and the flush states are yet to come.

- Adjusted the Active Alarm List screen a little to be able to show all the current Alarm messages without cropping.

  1. … 26 more files in changeset.
DEN-8533 & DEN-8693

Merge and support

  1. … 44 more files in changeset.
DEN-8519: Implementations [MVC]

  1. … 15 more files in changeset.
DEN-8317: Implementation: Merge the Wi-Fi into the code.

- Mainly the WiFi integration

- Some other support tasks:

| Support : Instruction and Kishen images [ Calyton, Nick ]

| Support : Alarm Messaging Parser

| Support : Changed the Manager Screen into a Monitoring Dialog and can be shown by DblTap on SDCard Indication on top/right

| Support : Modified the Heat values to float on Monitoring Dialog

| Support/Bug : Fixed the Alarm Message Bug

  1. … 107 more files in changeset.
DEN-7831: posTx: Implementation [Simulator/Testing]

- Disinfection

  1. … 39 more files in changeset.
DEN-8052: posTx: Implementation [Messaging] (Disinfection)

- Disinfection MVC

- There is still a state message and also some parts in qml for the progress and states during the disinfection.

  1. … 38 more files in changeset.
DEN-7833: Implementations [Merge the Wi-Fi, Date/Time into the code]

- Prepared the fundamentals of the Settings and Keyboard

- Added DateTime MVC and tested with the simulator.

- So many other debugging and improvement

  1. … 84 more files in changeset.
DEN-7829: posTx: Implementation [Messaging] ( 1 / ? )

  1. … 333 more files in changeset.
DEN-7147: Fixed a bug on Sub-StepIndicator on bottom of the instructions

- Which was causing that to not to show correct number of the steps and titles.

- removed #include "MModel.h" in all the possible cases and include the specific model since the MModel has too much include.

- Showing the Heparin setup in the CART_INSTALL state only if we have a heparin volume setup.

- created a common template function name enumString in Gui namespace to get the enum name as string.

  1. … 72 more files in changeset.
DEN-7377: preTx: Implementation [Dynamic Instruction Loading] ( 2 )

DEN-7457: Meetings & Support - General purpose

  1. … 51 more files in changeset.
DEN-7408: preTx: Implementation [Navigation] ( 3 )

- Added Rejection reason texts.

- Removed unused view.

- Fixed heparin ranges.

  1. … 13 more files in changeset.
DEN-7518: preTx: Implementation [Screens] ( 3 )

- The first round of the pre-treatment flow works.

  1. … 66 more files in changeset.
DEN-7420: preTx: Implementation [Messaging] ( 3 )

  1. … 64 more files in changeset.
DEN-7140: Implementation [Messaging] ( 1 )

- Added progress data Model/View which are:

ID_DGFilterFlush = 0x6000, // 96

ID_SelfTestNoCartridge = 0x6100, // 97

ID_SelfTestDry = 0x6300, // 99

ID_DisposablesPrime = 0x4300, // 67

  1. … 34 more files in changeset.
DEN-7140: Implementation [Messaging] ( 1 )

- PreTreatmentStates message has been added

  1. … 14 more files in changeset.