Since trimmer heater is enabled, no need of temp compensation. only for testing purposes, temp compensation is needed. Hence by default, temp compensation is disabled.

Since trimmer heater is enabled, no need of temp compensation. only for testing purposes, temp compensation is needed. Hence by default, temp compensation is disabled.

For spent chamber fill, we don't know how low the liquid level is ( in Chamber H) and hence decided not to turn on the trimmer heater for safety reasons. For bicarb fill, the dry bicart code should...

For spent chamber fill, we don't know how low the liquid level is ( in Chamber H) and hence decided not to turn on the trimmer heater for safety reasons. For bicarb fill, the dry bicart code should cover the actuators status. the current bicarb chamber fill code here should be updated with the newly implemented dry bi cart code changes.

Mis-spelled "Stabilized".

Mis-spelled "Stabilized".

I think you can do this in 1 line of code using the RANGE macro in Common.h.

I think you can do this in 1 line of code using the RANGE macro in Common.h.

What should trimmer heater be doing in these spent/bicarb chamber states?

What should trimmer heater be doing in these spent/bicarb chamber states?

I would think this would be enabled by default.

I would think this would be enabled by default.

LEAHI-DD-FIRMWARE-LDT-1473_Ultrafiltration - DD
LEAHI-DD-FIRMWARE-LDT-1473_Ultrafiltration - DD
LDT-2198 was merged into this branch after being merged into staging_alpha. Branch will be killed and relevant code changes were reviewed appropriately.

LDT-2198 was merged into this branch after being merged into staging_alpha. Branch will be killed and relevant code changes were reviewed appropriately.

Done.

Done.

Align comments in all of this switch cases

Align comments in all of this switch cases

Done.

Done.

RESOLVED IN CODE WALKTHROUGH.

RESOLVED IN CODE WALKTHROUGH.

Done

Done

Done

Done

Done

Done

Done

Done

Done

Done

Appears to be dialysate to dialyzer flow rate.

Appears to be dialysate to dialyzer flow rate.

Looking at the implementation of this function, it appears that this function is setting dialysateFlowRate to target rate only when delivering dialysate to the dialyzer and to zero in all other cas...

Looking at the implementation of this function, it appears that this function is setting dialysateFlowRate to target rate only when delivering dialysate to the dialyzer and to zero in all other cases. Consider changing variable name to something like dialysateToDialyzerFlowRate and updating function description in header to make this more clear.

0.0F.