LEAHI-DD-FIRMWARE-LDT-3749_Ability to set operation sub mode on DD subsystem
LEAHI-DD-FIRMWARE-LDT-3749_Ability to set operation sub mode on DD subsystem
Balancing chamber switching control

Balancing chamber switching control

Can this statement be 'else if' case after BC switch only request handling (after line 1013). Just in case both requests (switch only and regular one) came together and only 'switch only' handled f...

Can this statement be 'else if' case after BC switch only request handling (after line 1013). Just in case both requests (switch only and regular one) came together and only 'switch only' handled first.

remove the space before false.

remove the space before false.

Remove blank line

Remove blank line

Remove blank line.

Remove blank line.

I tried the suggested change and tested. But it did not provide the expected results. If a on was requested while an off was still pending to be processed, the off-request flag gets cleared without...

I tried the suggested change and tested. But it did not provide the expected results.
If a on was requested while an off was still pending to be processed, the off-request flag gets cleared without the actual request being processed and the off request was never executed.

LEAHI-DD-FIRMWARE-LDT-2004_Dialysate Composition - DD
LEAHI-DD-FIRMWARE-LDT-2004_Dialysate Composition - DD
LEAHI-DD-FIRMWARE-LDT-2004_Dialysate Composition - DD
LEAHI-DD-FIRMWARE-LDT-2004_Dialysate Composition - DD
LEAHI-DD-FIRMWARE-LDT-3749_Ability to set operation sub mode on DD subsystem
LEAHI-DD-FIRMWARE-LDT-3749_Ability to set operation sub mode on DD subsystem
Remove blank line and comment saying we're not doing anything (because now we're doing something).

Remove blank line and comment saying we're not doing anything (because now we're doing something).

isBalChamberSwitchingOffRequested is an output.

isBalChamberSwitchingOffRequested is an output.

Should we set the other switch to FALSE, just in case?

Should we set the other switch to FALSE, just in case?

LEAHI-DD-FIRMWARE-LDT-1195_DD: Request for a variable for balancing chamber switching to be active (T/F)
LEAHI-DD-FIRMWARE-LDT-1195_DD: Request for a variable for balancing chamber switching to be active (T/F)
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 121 more files in changeset.
Bamboo Commit: Updated the Copyright section and replaced tabs with 4 spaces

  1. … 121 more files in changeset.
Done.

Done.

Done.

Done.

Done.

Done.

Done.

Done.

Done

Done

Same as Gen Dialysate - this should be else if and switch statement should be in a final else.

Same as Gen Dialysate - this should be else if and switch statement should be in a final else.

stop should be capitalized.

stop should be capitalized.

Remove extra blank line.

Remove extra blank line.

I think these two conditions above the switch statement should end the state processing. So the second condition should be an else if and combined i.e. if ( ( genDialysateState != DD_GEND_DIALYSATE...

I think these two conditions above the switch statement should end the state processing.
So the second condition should be an else if and combined i.e. if ( ( genDialysateState != DD_GEND_DIALYSATE_DELIVERY_PAUSE ) && ( TRUE == areInletWaterConditionsAlarmsActive() ) ).
And then another else where the switch statement should go.
Hydraulic chamber and updating treatment settings should maybe be moved above all of this so they always happen.